DWL@DWL10000845240

Версия Язык
Операционная система
Дата
Размер
Тип Загрузка
1.1.0.0 * 05.03.2026 2 МБ EXE AS6_HW_X20SBD4M1.exe
Описание V6.0 HW Upgrade (X20SBD4M1)

Revision information X20SBD4M1

Version 1.1.0.0:

ID: TDYD-10597
STO activation at high speeds can induce overvoltage
During the operation of stepper motors at high speeds,deactivation the PWM-Output stage (e.g. trigger of STO input) can induce unacceptably high voltages. To protect the device, a speed limit has been implementedbased on the voltage constant.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\13213_2.fw(101)

Version 1.0.0.0:

ID: TDYD-10100
Support for the X20SBD4M1 module
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\13213_2.fw(100)
Версия Язык
Операционная система
Дата
Размер
Тип Загрузка
1.0.0.0 * 29.01.2026 2 МБ EXE AS6_HW_X20SBD4M1.exe
Описание V6.0 HW Upgrade (X20SBD4M1)

Revision information X20SBD4M1

Version 1.0.0.0:

ID: TDYD-10100
Support for the X20SBD4M1 module
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\13213_2.fw(100)