DWL@DWL10000882189
| Versie | Taal | Besturingssysteem | Datum | Grootte | Type | Download |
|---|---|---|---|---|---|---|
| 2.6.0.1 | * | 03-11-2026 | 24 MB | EXE | AS6_HW_8I66xxxxxxx.0P-xxx.exe | |
| Omschrijving |
V6.0 HW Upgrade (8I66xxxxxxx.0P-xxx) Revision information 8I66xxxxxxx.0P-xxx Version 2.6.0.1: ID: Firmware signature enables automatic verification of the authenticity on the target system The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source. Channel description changed: no Configuration description changed: yes Firmware changed:no Version 2.6.0.0: ID: 754460 Interaction between communication card and drive revised Up to now, the internal communication between communication card and drive was kept on Schneider's default setting. Now, operation mode was adapted to the circumstances of a POWERLINK network. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\62043_1.fw(201), 1\62043_2.fw(201), 1\62043_30.fw(201) Version 2.5.1.0: ID: 741905 mappMotioninplementation restored Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 742675 Harmonization of module configuration (Group: Axis management) The user surfaces for the product group ACOPOSinverter was designed specially. One demands is to provide a homogeneous structure for all devices of the product generation. This harmonization of several device from different vendorsresults in a similar commissioning process and simplisfies a product change within the product group. The extension of the product group by the ACPi P96 forced adaptions of the general structure. These changes are rolled out to the products thathave already been published. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\62043_1.fw(180), 1\62043_2.fw(180) Version 2.5.0.0: ID: 737970 Continuous product improvement Optimization of initial commissioning. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\62043_1.fw(180), 1\62043_2.fw(180) Version 2.4.0.0: ID: 717065 Boot routine of PLK communication card revised The state of the reset-line of the inverter is now taken into account during re/booting Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:722995 DS402-PLK-objects revised Revision and correction of PLK object 0x6060, 0x6061 and 0x6502 (DS402 operation mode) Channel description changed: Yes Configuration description changed: No Firmware changed:No ID: 726765 Parameter FLR revised The parameter FLR is added to the module configuration in Automation Studio. It turn on the function"Catch on the fly", that permitts the restart of a coasting motor (motor in freewheel stop). Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 726780 NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 726785 POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438) POWERLINK Security Vulnerability (CVE-2020-13987) The POWERLINK IP stack was affected by a security vulnerability impacting thechecksum calculation of TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IP stack was affected by a securityvulnerability impacting fragmented packet reassembly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 730180 Automation Runtime versions greater D3.10 supported Support of Automation Runtime versions greater D3.10 (up to now minimum version required was D4.10) Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\62043_1.fw(170), 1\62043_2.fw(170) Version 2.3.3.0: ID: 714055 Configuration parameters for current and torque limitation revised Structural bug in hardware upgrade version 2.3.2.0 eliminated. The configuration parameters for current and torque limitation were not shown if function model "Motion Control" was chosen. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 714065 Single bits initialisation (parameter BRH) revised The configuration bits of parameter BRH can be downloaded as shown in the configuration view. Channel description changed: No Configuration description changed:No Firmware changed: No Firmware: 1\62043_1.fw(160), 1\62043_2.fw(160) Version 2.3.2.0: ID: 665010 Filter conditions for hardware catalog revised The ACOPOSinverter is still shown, if module selection is resticted to "single axis" modules. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 685600 Configuration parameter SFR revised If the operating mode for long motor cable is selected (Parameter SVL = YES), the value range forthe stator frequency is restricted; the valid maximum isreduced to 4 kHz (Instead of this, the minimum value was raised to 4 kHz in previous versions). Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 695265 External error detection revised The error message EPF1 does not have to be acknowledged after a restart - even not if the external error detection is used in low active mode. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 701975 Correction of configuration surface The "axis behavior in case of error" can be defined by the user(see Module configuration: Function model > ACOPOSinverter parameters >General hardware setup > Drive > Axis management > Reference model > Stop commands > DS 402 state machine). The adaption eliminates astructural fault in the confguration surface that can cause a reset of this userdefined configuration in case of changing the the general hardware setup. CAUTION: After changing to this version, the setting for the "axis behavior in case of error" must be verified. This is ecessary especilyy if the general hardware setup for synchronous motors or asynchronous motors with holding brake is used. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 703004 Restrictions forse in AutomationStudio (Aprol-Edition) added Due to the faulty processing of the hardware description files in the Aproledition of AutomationStudio, the product release for Aprol projects must be restricted to APROL R 4.2-06 and higher. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 703035 Module configuration correted The module configuration of function model "motion configuration" seemed tobe able to switch between rpm and Hz as setpoint unit. However, the switch works only if function model "direct control" was selected before. The ineffective swtich was eliminated from the configuration surface. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\62043_1.fw(160), 1\62043_2.fw(160) Version 2.3.0.0: ID: 698020 Starting procedure (occasionalILF-error) revised with support for the new hardwarevariant 2 On few devices, several powercycles or reboots could lead to an ILF-error, which then has to be acknowledged by another powercycle. This behavoir was changed (better timings between inverter and option card) so that no ILF-error occurs on powerup. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 698240 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\62043_1.fw(160), 1\62043_2.fw(160) Version 2.2.0.1: ID: 645070 Support for mappMotion Support for mappMotion (from version 5.8) The usage of the onboard POWERLINK interfaces on ARM CPUs (e.g. X20CP04xx) for mappMotion is restricted to the following minimun versions of AutomationRuntime; M4.34, F4.45, C4.53, C4.63, A4.72 Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 657105 List of monitoring data points extended The list of optional monitoring data points was extended to enable access to unfiltered values (SRFR, SOTR, SLCR, SOPR, SULN) Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\62043_1.fw(110) Version 1.1.0.5: ID: 638530 POWERLINK communication revised Ongoing product improvements - Ring redundancy: Cannot address the CN that closes the ring - Optimization of hub behavior - Shortened preamble of Ethernet frame leading to incorrectly detected CRCerrors - DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 638540 Download of Parameter "OPL" revised The parameter "OPL" can be used to activate/deactivate the supervision "output phase loss". Channel description changed: No Configuration description changed: No Firmware changed: No ID: 638545 Configuration view extended and corrected Configuration view revised Access: Configuration parameter RSF added Intermediate circuit: Configuration parameter DCCM always visible Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 638675 Monitoring data point GDLS corrected The optional monitoring data point GDLS was renamed in order to aviod collisions with data point SLSS. CAUTION: this change my unlink former connections to the GDLS data point on the I/O-mapping. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 638690 Download of motor data for synchronous motors enabled Bug eliminated which avoided the download of motor data for synchronous motors. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 638695 List of monitoring data points extended The list of optional monitoring data points was extended by data point SMSS(status of safety function "Safe Maximum Speed") Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 645030 Additional ACOPOSinverter types The configuration view was extended for additional ACOPOSinverter P66 (input masks for motor nameplate, intermediate circuit type). Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 645035 Motor nameplate templets for 8I66T6 revised The default values of the configuration parameters (NCR, ITH) were corrected for the motor nameplate templets of 8I66T6. Channel description changed: No Configuration descriptionchanged: Yes Firmware changed: No ID: 645055 Download of the "I²t" motor temperature model revised The parameters of the "I²t" motor temperature model (ITH, MTM, THT) can be downloaded as shown in the configuration view. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 645975 Behavior of 7 segment display adapted After downloading the parameter set of the ACOPOSinverter, the display switches to the actual state of the drive. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 645990 Maximum speed definition revised The "TFR [Hz]" does not need to be configured anymore if the "rpm" referencemodel is used. The valid maximum speed of the axis is defined exclusively by parameter "SMA [rpm]". Channel description changed: No Configurationdescription changed: Yes Firmware changed: No Firmware: 1\62043_1.fw(110) Version 1.0.2.0: ID: 631660 Support ACOPOSinverterP66-P Support for AutomationStudio Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\62043_1.fw(101) |
|||||