DWL@DWL10000791401
| Versione | Lingua | Sistema operativo | Data | Taglia | Tipologia | Download |
|---|---|---|---|---|---|---|
| 3.0.0.0 | * | 25/07/2025 | 777 KB | EXE | AS6_HW_X20cSD1207.exe | |
| Descrizione |
V6.0 HW Upgrade (X20cSD1207) Revision information X20cSD1207 Version 3.0.0.0: ID: FUVI-11177 New data sheet V3.0.0 New data sheet V3.0.0 Channel description changed: No Configuration description changed: No Firmware changed: No ID: FUVI-11176 First official release for Safety+ First official release for Safety+ Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\57803_1.fw(577) Version 2.5.1.2: ID: 783550 Configuration for Power Calculation available The Configuration for Power Calculation is now available in Automation Studio Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\57803_1.fw(577) Version 2.5.1.1: ID: 744605 Failsafe due to voltage monitoring Sporadically the voltage monitoring could cause a failsafe with logger messages 99849 and 103945. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 749635 Correctionof SafeFrequency during channel reset Correction of SafeFrequency duringchannel reset Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 749640 New data sheet V2.15 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 757105 Correction of the I/O update time in the documentation for AA/BB/ configuration Correction of the I/O update time in the documentation AA/BB/ configuration Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\57803_1.fw(577) Version 2.5.0.0: ID:735480 Acknowledge channel errors while input frequency is unequal zero Acknowledge channel errors while input frequency is unequal zero Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\57803_1.fw(576) Version 2.4.0.0: ID: 719730 Failsafe at every boot It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communicationerror EPS" or -1073565945/-1073561849 "Received crc data is not equal to sentcrc data" Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 726585 The power calculation of the modules is supported The data for the power calculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 727110 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\57803_1.fw(575) Version 2.3.1.0: ID: 706295 Limit values for themodule cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 706380 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 706440 Propagation delay statistics The Propagation delay statisticscan now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 706445 Improvement of the internal voltage monitoring. Improvement of the internalvoltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\57803_1.fw(574) Version 2.3.0.0: ID: 688685 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 688825 Calculation of the internal edge counter corrected. Calculation of the internal edge counter at overflow corrected. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\57803_1.fw(573) Version 2.2.0.1: ID: 650660 Optimizing of the firmware By optimizing the firmware the bug has been fixed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 670595 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware:10\57803_1.fw(572) Version 2.1.0.0: ID: 644185 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching tomapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\57803_1.fw(570) Version 1.10.10.0: ID: 650655 Optimizing of thefirmware By optimizing the firmware the bug has been fixed. Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\57803_1.fw(570), 6\57803_1.fw(331) Version 1.10.9.1: ID: 643245 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 6\57803_1.fw(330) Version 1.10.9.0: ID: 618185 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\57803_1.fw(330) Version 1.10.1.0: ID: 582860 overflow of frequency in AB mode In AB mode now always the positive max value is shown if overflow of frequencyoccures. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 582865 increase tolerance for wire break detection Tolerance for wire break detection in AB/AB mode was increased to half of the timebase. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 582870 new values for timebase added new values for timebase added: 20ms, 200ms, 2s, 20s Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\57803_1.fw(325) Version 1.10.0.6: ID: 533040 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533130 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533205 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 5\57803_1.fw(302), 6\57803_1.fw(320) Version 1.10.0.0: ID: 474315 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 474320 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 5\57803_1.fw(302), 6\57803_1.fw(320) Version 1.9.1.0: ID: 431940 Stability problem in Mode AB/A/B solved An error in the evaluation of the inputSignal in mode AB/A/B was solved andtherefore the stability of the module was inproved in this mode Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 5\57803_1.fw(302) Version 1.9.0.0: ID: 419990 The module also supports SafetyRelease 1.9 Starting with this version, the module also supports SafetyRelease 1.9 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 419995 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 4\57803_1.fw(300) Version 1.7.0.5: ID: 394015 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 4\57803_1.fw(300) |
|||||
| Versione | Lingua | Sistema operativo | Data | Taglia | Tipologia | Download |
| 2.5.1.2 | * | 24/06/2024 | 1 MB | EXE | AS6_HW_X20cSD1207.exe | |
| Descrizione |
V6.0 HW Upgrade (X20cSD1207) Revision information X20cSD1207 Version 2.5.1.2: ID: 783550 / Support ID: 400412437 Configuration for Power Calculation available The Configuration for Power Calculation is now available in Automation Studio Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\57803_1.fw(577) Version 2.5.1.1: ID: 744605 Failsafe due to voltage monitoring Sporadically the voltage monitoring could cause a failsafe with logger messages 99849 and 103945. Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 749635 Correction of SafeFrequency during channel reset Correction of SafeFrequency during channel reset Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 749640 New data sheet V2.15 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 757105 Correction of the I/O update time in the documentation for AA/BB/ configuration Correction of the I/O update time in the documentation AA/BB/ configuration Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\57803_1.fw(577) Version 2.5.0.0: ID: 735480 Acknowledge channel errors while input frequency is unequal zero Acknowledge channel errors while input frequency is unequal zero Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\57803_1.fw(576) Version 2.4.0.0: ID: 719730 Failsafe at every boot It could happen under rare conditions that the module is stuckin failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849"Received crc data is not equal to sent crc data" Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 726585 The power calculation of the modules is supported The data for the power calculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 727110 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\57803_1.fw(575) Version 2.3.1.0: ID: 706295 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 706380 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 706440 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 706445 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\57803_1.fw(574) Version 2.3.0.0: ID: 688685 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 688825 /Support ID: 400314138, 400320310 Calculation of the internal edge counter corrected. Calculation of the internal edge counter at overflow corrected. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\57803_1.fw(573) Version 2.2.0.1: ID: 650660 / Support ID: 400279512 Optimizing of the firmware By optimizing the firmware the bug has been fixed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 670595 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\57803_1.fw(572) Version 2.1.0.0: ID: 644185 major (even incompatible) changes for mappSafety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\57803_1.fw(570) Version 1.10.10.0: ID: 650655 / Support ID: 400279512 Optimizing of the firmware By optimizing the firmware the bug has been fixed. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\57803_1.fw(570), 6\57803_1.fw(331) Version 1.10.9.1: ID: 643245 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 6\57803_1.fw(330) Version 1.10.9.0: ID: 618185 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\57803_1.fw(330) Version 1.10.1.0: ID: 582860 overflow of frequency in AB mode In AB mode now always the positive max value is shown if overflow of frequency occures. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 582865 increase tolerance for wire break detection Tolerance for wire break detection in AB/AB mode was increased to half of the timebase. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 582870 new values for timebase added new values for timebase added: 20ms, 200ms, 2s, 20s Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\57803_1.fw(325) Version 1.10.0.6: ID: 533040 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533130 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533205 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 5\57803_1.fw(302), 6\57803_1.fw(320) Version 1.10.0.0: ID: 474315 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 474320 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration descriptionchanged: Yes Firmware changed: No Firmware: 5\57803_1.fw(302), 6\57803_1.fw(320) Version 1.9.1.0: ID: 431940 Stability problem in Mode AB/A/B solved An error in the evaluation of the input Signal in mode AB/A/B was solved and therefore the stability of the module was inproved in this mode Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 5\57803_1.fw(302) Version 1.9.0.0: ID: 419990 The module also supports SafetyRelease 1.9 Starting with this version, the module also supports SafetyRelease 1.9 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No ID: 419995 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 4\57803_1.fw(300) Version 1.7.0.5: ID: 394015 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 4\57803_1.fw(300) |
|||||