DWL@DWL10000313623

Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
1.6.1.0 * 19/02/2016 1 Mo EXE AS3.0_HW_X20IF1061-1.exe
Description V3.0 HW Upgrade (X20IF1061-1)

Revision information X20IF1061-1

Version 1.6.1.0:

ID: 236395
Add ModulOK in I/O Mapping
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 466215
FDT/DTM Cycle Time change
Change parameter name "Cycle time [µs]" to "Data exchange time (CPU-netX) [µs]"
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\42774a1.fw(33), 1\42774_1.fw(12)

Version 1.6.0.0:

ID: 450560 / Support ID: 400149579
X20IF1061-1: NetX: Cyclic statusbits wrong when cable is disconnected
Channeldescription changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42774a1.fw(33), 1\42774_1.fw(12)

Version 1.5.0.1:

ID: 244480
Module information available (SerialNumber, ModuleID, HardwareVariant, FirmwareVersion)
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 357105
Dynamic configuration
The name of the generated netX module can be freely assigned in order to enable a dynamic configuration ofnetX modules in AR.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 401110
PROFIBUS redundancy: Problem switching to active operation
Master parametersare not applied when switching from standby to active operation.
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42774a1.fw(30), 1\42774_1.fw(12)

Version 1.5.0.0:

ID: 366505
redundancy behaviour was adjusted
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 382760
Master-Redundancy got deactivated for the AutomationStudio 4.0
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 384470
master redundancy
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42774a1.fw(29), 1\42774_1.fw(12)

Version 1.3.0.0:

ID: 284360
New firmware: PNO certification
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 332500
Alarms not being received
Incoming alarms cannot be received when using the nxdpmAlarmReceive() function block.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42774a1.fw(27), 1\42774_1.fw(12)

Version 1.1.0.0:

ID: 257410
Vendor ID changed
Module notifies now with the B&R Vendor ID
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42774a1.fw(19), 1\42774_1.fw(12)

Version 1.0.2.0:

ID: 240725
X20 Interface PROFIBUSDP Master, Configuration of netX cycle time
X20 Interface PROFIBUS DP Master, Configuration of netX cycle time.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\42774a1.fw(17), 1\42774_1.fw(12)

Version 1.0.1.1:

ID: 237600
Interface module PROFIBUS DP Master, new online help
Interface module PROFIBUS DP Master, new online help
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42774a1.fw(17), 1\42774_1.fw(12)

Version 1.0.1.0:

ID: 235845
Interface module PROFIBUS Master, first version
Interface module PROFIBUS Master, first version
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42774a1.fw(17), 1\42774_1.fw(12)