DWL@DWL10000782487
| Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
|---|---|---|---|---|---|---|
| 1.08 | * | 03/08/2026 | 3 Mo | ZIP | UPG_APC4100_MTCX_V0108_EFI.zip | |
| Description |
APC4100 Firmware upgrade (MTCX, SDL4T) ---------------------------------------------------------------- ATTENTION! Possible upgrade problems and version dependency ---------------------------------------------------------------- 1. Do not reset or switch off the device during the upgrade process !!! 2. If a UPS is connected to the system, the battery unit must be disconnected or the Power button must be pressed (to set the system in standby mode) after the upgrade is done, but before the required Power Off/On is done. Otherwise the firmware upgrade is not complete, because the UPS will provide the system with power. 3. A Extended upgrade for the SDL4T Firmware is only necessary if an SDL4T firmware less than V01.00 is installed. 4. Starting with SDL4T Firmware V01.00, a downgrade to a version smaller then V01.00 is not possible. 5. Starting with SDL4T Firmware V01.00, a Automation Panel Firmware update for the SDL4R Firmware at least from V06.14 and HDBT Firmware at least from V01.00 is necessary. ---------------------------------------------------------------- Version 01.08 / 07/15/2026 / MIK !MANDATORY UPDATE! ---------------------------------------------------------------- Content LIESMICH.txt 01.08 NEW README.txt 01.08 NEW STARTUP.nsh 01.08 NEW MTCXAPC4100.nsh 01.03 SDL4TAPC4100.nsh 01.08 NEW MTCXSVC.efi 22.21 NEW 11544_0.fw 01.08 NEW 11545_0.fw 01.08 NEW 11546_0.fw 01.08 NEW 11547_0.fw 01.08 NEW 11548_0.fw 01.08 NEW 14988_0.fw 01.08 NEW 61159_0.fp (SDLT) 00.04 NEW 11933_0.fp (SDL4T) 01.05 NEW Change(s) 11544_0.fw, 11545_0.fw, 11546_0.fw, 11547_0.fw, 11548_0.fw, 14988_0.fw (MTCX Firmware): - Bug fix: The power LED on the 5AC901.ISIO-00 was not working. - Optimizations to CAN communication with the 5AC901.ICAN-01. - Optimized internal power supply. - Support for the 5APC4100.TGL5-000 cpu board. 61159_0.fp (FPGA FW f. 5ACCLI02.SDL0-000): - First version in this upgrade package. 11933_0.fp (SDL4T Firmware): - Updated HDBASET2 FW: Sporadically, when connecting a USB hard drive to the USB ports of the SDL4 receiver, a situation occurred where all USB ports stopped working. This behavior only occurs when an SDL4 converter box is also used without a USB cable. Workaround: Use the SDL4 converter box with a USB cable. Bug fix: Update all SDL4 components to the latest version. MTCXSVC: - Support for newer product family. ATTENTION! Possible upgrade problems and version dependency, see above. |
|||||
| Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
| 1.07 | * | 28/05/2025 | 2 Mo | ZIP | UPG_APC4100_MTCX_V0107_EFI.zip | |
| Description |
APC4100 Firmware upgrade (MTCX, SDL4T) ---------------------------------------------------------------- ATTENTION! Possible upgrade problems and version dependency ---------------------------------------------------------------- 1. Do not reset or switch off the device during the upgrade process !!! 2. If a UPS is connected to the system, the battery unit must be disconnected or the Power button must be pressed (to set the system in standby mode) after the upgrade is done, but before the required Power Off/On is done. Otherwise the firmware upgrade is not complete, because the UPS will provide the system with power. 3. A Extended upgrade for the SDL4T Firmware is only necessary if an SDL4T firmware less than V01.00 is installed. 4. Starting with SDL4T Firmware V01.00, a downgrade to a version smaller then V01.00 is not possible. 5. Starting with SDL4T Firmware V01.00, a Automation Panel Firmware update for the SDL4R Firmware at least from V06.14 and HDBT Firmware at least from V01.00 is necessary. ---------------------------------------------------------------- Version 01.07 / 03/10/2025 / MIK !MANDATORY UPDATE! ---------------------------------------------------------------- Content LIESMICH.txt 01.07 NEW README.txt 01.07 NEW STARTUP.nsh 01.03 MTCXAPC4100.nsh 01.03 SDL4TAPC4100.nsh 01.03 MTCXSVC.efi 21.30 11544_0.fw 01.07 NEW 11545_0.fw 01.07 NEW 11546_0.fw 01.07 NEW 11547_0.fw 01.07 NEW 11548_0.fw 01.07 NEW 11933_0.fp (SDL4T) 01.04 Change(s) 11544_0.fw, 11545_0.fw, 11546_0.fw, 11547_0.fw, 11548_0.fw (MTCX Firmware): - Support for PCIe cards, which are using the Emergency Power Break mechanism. ATTENTION! Possible upgrade problems and version dependency, see above. |
|||||
| Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
| 1.06 | * | 19/06/2024 | 2 Mo | ZIP | UPG_APC4100_MTCX_V0106_EFI.zip | |
| Description |
APC4100 Firmware upgrade (MTCX, SDL4T) ---------------------------------------------------------------- ATTENTION! Possible upgrade problems and version dependency ---------------------------------------------------------------- 1. Do not reset or switch off the device during the upgrade process !!! 2. If a UPS is connected to the system, the battery unit must be disconnected or the Power button must be pressed (to set the system in standby mode) after the upgrade is done, but before the required Power Off/On is done. Otherwise the firmware upgrade is not complete, because the UPS will provide the system with power. 3. A Extended upgrade for the SDL4T Firmware is only necessary if an SDL4T firmware less than V01.00 is installed. 4. Starting with SDL4T Firmware V01.00, a downgrade to a version smaller then V01.00 is not possible. 5. Starting with SDL4T Firmware V01.00, a Automation Panel Firmware update for the SDL4R Firmware at least from V06.14 and HDBT Firmware at least from V01.00 is necessary. ---------------------------------------------------------------- Version 01.06 / 04/23/2024 / MIK !MANDATORY UPDATE! ---------------------------------------------------------------- Content LIESMICH.txt 01.06 NEW README.txt 01.06 NEW STARTUP.nsh 01.03 MTCXAPC4100.nsh 01.03 SDL4TAPC4100.nsh 01.03 MTCXSVC.efi 21.30 11544_0.fw 01.06 NEW 11545_0.fw 01.06 NEW 11546_0.fw 01.06 NEW 11547_0.fw 01.06 NEW 11548_0.fw 01.06 NEW 11933_0.fp (SDL4T) 01.04 Change(s) 11544_0.fw, 11545_0.fw, 11546_0.fw, 11547_0.fw, 11548_0.fw (MTCX Firmware): - Optimized internal power supply. ATTENTION! Possible upgrade problems and version dependency, see above. |
|||||
| Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
| 1.05 | * | 15/04/2024 | 2 Mo | ZIP | UPG_APC4100_MTCX_V0105_EFI.zip | |
| Description |
APC4100 Firmware upgrade (MTCX, SDL4T) ---------------------------------------------------------------- ATTENTION! Possible upgrade problems and version dependency ---------------------------------------------------------------- 1. Do not reset or switch off the device during the upgrade process !!! 2. If a UPS is connected to the system, the battery unit must be disconnected or the Power button must be pressed (to set the system in standby mode) after the upgrade is done, but before the required Power Off/On is done. Otherwise the firmware upgrade is not complete, because the UPS will provide the system with power. 3. A Extended upgrade for the SDL4T Firmware is only necessary if an SDL4T firmware less than V01.00 is installed. 4. Starting with SDL4T Firmware V01.00, a downgrade to a version smaller then V01.00 is not possible. 5. Starting with SDL4T Firmware V01.00, a Automation Panel Firmware update for the SDL4R Firmware at least from V06.14 and HDBT Firmware at least from V01.00 is necessary. ---------------------------------------------------------------- Version 01.05 / 01/10/2024 / MIK !MANDATORY UPDATE! ---------------------------------------------------------------- Content LIESMICH.txt 01.05 NEW README.txt 01.05 NEW STARTUP.nsh 01.03 MTCXAPC4100.nsh 01.03 SDL4TAPC4100.nsh 01.03 MTCXSVC.efi 21.30 11544_0.fw 01.05 NEW 11545_0.fw 01.05 NEW 11546_0.fw 01.05 NEW 11547_0.fw 01.05 NEW 11548_0.fw 01.05 NEW 11933_0.fp (SDL4T) 01.04 Change(s) 11544_0.fw, 11545_0.fw, 11546_0.fw, 11547_0.fw, 11548_0.fw (MTCX Firmware): - Optimized internal power supply. - Powerlimitation (Psys) prepared (BIOS required from V01.06). - Support for 5ACCIF04.FPLK-000. - Bugfix: WakeUp from S3 (BIOS required from V01.06). ATTENTION! Possible upgrade problems and version dependency, see above. |
|||||