1.1.0.0 * 04.09.2019 5 MB EXE AS3.0_HW_X20cAO2438.exe
Descripción V3.0 HW Upgrade (X20cAO2438)

Revision information X20cAO2438

Version 1.1.0.0:

ID: 562755
Improved reset behavior
In rare cases, analog value measurement does not start after a reset.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 658110
Module documentation revised
Data sheet V 1.40
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: No
Firmware: 1\57873_2.fw(110)

Version 1.0.7.1:

ID: 515650
Internal Revision
Adaption of hardware description file for use with AS 4.3.2.x
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 515800
Max. data transfer revised
Warning/Error message will be shown, when 31 or more Byte are defined in input direction in AS.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 521155
Module documentation revised
Data sheet V 1.22
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57873_2.fw(61)

Version 1.0.7.0:

ID: 492170
DTM diagnose revised
DTM diagnosis function can be used on cyclic data transfer as well.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 499430
Support for module DTM revised
The user defined item designation is shown in livelist of module (required AR: B4.25 or higher)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 499435
Module documentation revised
Data sheet V 1.21
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 503625
Ecad data (EPlan) corrected
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\57873_2.fw(61)

Version 1.0.6.5:

ID: 492170
DTM diagnose revised
DTM diagnosis function can be used on cyclic data transfer as well.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 499430
Support for module DTM revised
The user defined item designation is shown in livelist of module (required AR: B4.25 or higher)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 499435
Module documentation revised
Data sheet V1.21
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57873_2.fw(61)

Version 1.0.0.3:

ID: 402915 / Support ID: 400142019
Multiplexed mode revised
FIO datapionts for multiplexed mode corrected.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\57873_2.fw(61)

Version 1.0.0.2:

ID: 342530
Support X20cAO2438
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57873_2.fw(61)
Versión Idioma
Sistema operativo
Fecha
Tamaño
Tipo Descargar
1.0.7.1 * 20.02.2017 2 MB EXE AS3.0_HW_X20cAO2438.exe
Descripción V3.0 HW Upgrade (X20cAO2438)

Revision information X20cAO2438

Version 1.0.7.1:

ID: 515650
Internal Revision
Adaption of hardware description file for use with AS 4.3.2.x
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 515800
Max. data transfer revised
Warning/Error message will be shown, when 31 or more Byte are defined in input direction in AS.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 521155
Module documentation revised
Data sheet V 1.22
Channel description changed: No
Configurationdescription changed: No
Firmware changed: No
Firmware: 1\57873_2.fw(61)

Version 1.0.7.0:

ID: 492170
DTM diagnose revised
DTM diagnosis function can be used on cyclic data transfer as well.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 499430
Support for module DTM revised
The user defined item designation is shown in livelist of module (requiredAR: B4.25 or higher)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 499435
Module documentation revised
Data sheet V 1.21
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 503625
Ecad data (EPlan) corrected
Channel description changed: Yes
Configuration description changed: No
Firmware changed:No
Firmware: 1\57873_2.fw(61)

Version 1.0.6.5:

ID: 492170
DTM diagnose revised
DTM diagnosis function can be used on cyclic data transfer as well.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 499430
Support for module DTM revised
The user defined item designation is shown in livelist of module (required AR: B4.25 or higher)
Channel description changed: No
Configuration description changed: Yes
Firmware changed:No

ID: 499435
Module documentation revised
Data sheet V 1.21
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57873_2.fw(61)

Version 1.0.0.3:

ID: 402915 / Support ID: 400142019
Multiplexed mode revised
FIO datapionts for multiplexed mode corrected.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\57873_2.fw(61)

Version 1.0.0.2:

ID: 342530
Support X20cAO2438
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57873_2.fw(61)