DWL@DWL10000303632

Version Language
Operating System
Date
Size
Type Download
1.2.0.0 * 07/23/2021 700 KB EXE AS4_HW_X20DO2321.exe
Description V4.0 HW Upgrade (X20DO2321)

Revision information X20DO2321

Version 1.2.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.1.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.0.3.0:

ID: 471455
Module documentation revised
Data sheet V3.12
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\8883_5.fw(816)

Version 1.0.2.4:

ID: 393050
Enhancement online-help files
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\8883_5.fw(816)

Version 1.0.2.3:

ID: 392850
Enhancements packed data point for outputs
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\8883_5.fw(816)

Version 1.0.2.2:

ID: 366249
APROL entries revised
Datapoint OSPValid corrected
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\8883_5.fw(816)

Version 1.0.2.1:

ID: 346505
OSP; system requirements
Minimum system requirements for functionmodell "OSP" are mentioned.
Channel description changed: no
Configuration description changed: No
Firmware changed: No
Firmware: 1\8883_5.fw(816)

Version 1.0.2.0:

ID: 317685
Additional function model "OSP mode"
OSP - Output Set Predefined

In OSP mode, the user defines the output behavior in case of connection loss between PLC and module.
In doing so the power supply of the module must be assured.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\8883_5.fw(816)

Version 1.0.1.0:

ID: 217440
Adaptation UART Re-Init
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\8883_5.fw(800)
Version Language
Operating System
Date
Size
Type Download
1.1.0.0 * 10/25/2019 696 KB EXE AS4_HW_X20DO2321.exe
Description V4.0 HW Upgrade (X20DO2321)

Revision information X20DO2321

Version 1.1.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.0.3.0:

ID: 471455
Module documentation revised
Data sheet V3.12
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\8883_5.fw(816)

Version 1.0.2.4:

ID: 393050
Enhancement online-help files
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\8883_5.fw(816)

Version 1.0.2.3:

ID: 392850
Enhancements packed data point for outputs
Channel description changed: Yes
Configurationdescription changed: No
Firmware changed: No
Firmware: 1\8883_5.fw(816)

Version 1.0.2.2:

ID: 366249
APROL entries revised
Datapoint OSPValid corrected
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\8883_5.fw(816)

Version 1.0.2.1:

ID: 346505
OSP; system requirements
Minimum system requirements for functionmodell "OSP" are mentioned.
Channel description changed: no
Configuration description changed: No
Firmware changed: No
Firmware: 1\8883_5.fw(816)

Version 1.0.2.0:

ID: 317685
Additional function model "OSP mode"
OSP - Output Set Predefined

In OSP mode, the user defines the output behavior in case of connection loss between PLC and module.
In doing so thepower supply of the module must be assured.
Channel description changed:Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\8883_5.fw(816)

Version 1.0.1.0:

ID: 217440
Adaptation UART Re-Init
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\8883_5.fw(800)
Version Language
Operating System
Date
Size
Type Download
1.0.3.0 * 03/23/2016 715 KB EXE AS4_HW_X20DO2321.exe
Description V4.0 HW Upgrade (X20DO2321)

Revision information X20DO2321

Version 1.0.3.0:

ID: 471455
Module documentation revised
Data sheet V3.12
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: No
Firmware: 1\8883_5.fw(816)

Version 1.0.2.4:

ID: 393050
Enhancement online-help files
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\8883_5.fw(816)

Version 1.0.2.3:

ID: 392850
Enhancements packed data point for outputs
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\8883_5.fw(816)

Version 1.0.2.2:

ID: 366249
APROL entries revised
Datapoint OSPValid corrected
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\8883_5.fw(816)

Version 1.0.2.1:

ID: 346505
OSP; system requirements
Minimum system requirements for functionmodell "OSP" are mentioned.
Channel description changed: no
Configuration description changed: No
Firmware changed: No
Firmware: 1\8883_5.fw(816)

Version 1.0.2.0:

ID: 317685
Additional function model "OSP mode"
OSP - Output Set Predefined

In OSP mode, the user defines the output behavior in case of connection loss between PLC and module.
In doing so the power supply of the module mustbe assured.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\8883_5.fw(816)

Version 1.0.1.0:

ID: 217440
Adaptation UART Re-Init
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\8883_5.fw(800)
Loading
Back to list

Please choose country and language