DWL@DWL10000818762
| Sürüm | Dil | İşletim sistemi | Tarih | Boyut | Tip | İndirme |
|---|---|---|---|---|---|---|
| 2.18.0.0 | * | 08/29/2025 | 3 MB | EXE | AS6_HW_X67BC8321-1.exe | |
| Açıklama |
V6.0 HW Upgrade (X67BC8321-1) Revision information X67BC8321-1 Version 2.18.0.0: ID: RKFY-9999 Support new HW-variant 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(438), 1\7735_3.fw(438), 1\7735_5.fw(438), 1\7735_6.fw(438) Version 2.17.0.0: ID: RKFY-9694 Added capability to disable Fast Link Down detection In the event ofinterferences on the network cable, the active Fast Link Down Detection very quickly leads to a complete loss of the link and thus to a failure of all subsequent stations. The Fast Link Down Detection can now be deactivated, which means that minor faults on the cable have less impact. Channel description changed: No Configuration description changed: Yes Firmware changed:Yes Firmware: 1\7735_1.fw(438), 1\7735_3.fw(438), 1\7735_5.fw(438) Version 2.15.0.0: ID: 758840 Optimization of asynchronous register access Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(433), 1\7735_3.fw(433), 1\7735_5.fw(433) Version 2.14.0.0: ID: 737320 NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 737325 POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438) POWERLINK Security Vulnerability (CVE-2020-13987) The POWERLINK IP stack was affected by a security vulnerability impacting thechecksum calculation of TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IP stack was affected bya security vulnerability impacting fragmented packet reassembly. Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 739450 Module documentation revised Data sheet V3.10 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(432), 1\7735_3.fw(432), 1\7735_5.fw(432) Version 2.11.1.0: ID: 697880 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7735_1.fw(430), 1\7735_3.fw(430), 1\7735_4.fw(210),1\7735_5.fw(430) Version 2.11.0.0: ID: 664415 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 664455 DNA: Hub of PLK BC active until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665780 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665870 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(430), 1\7735_3.fw(430), 1\7735_4.fw(210), 1\7735_5.fw(430) Version 2.10.0.0: ID: 628740 Timing optimizations for hardware variants 1 and 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(428), 1\7735_3.fw(428), 1\7735_4.fw(210), 1\7735_5.fw(428) Version 2.9.3.0: ID: 639720 Alignment of AS output according to the FieldBusDesigner Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7735_1.fw(427), 1\7735_3.fw(427), 1\7735_4.fw(210), 1\7735_5.fw(427) Version 2.9.0.0: ID: 629040 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629105 DNA: BC ashead-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629185 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629250 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(427), 1\7735_3.fw(427), 1\7735_4.fw(210), 1\7735_5.fw(427) Version 2.8.0.0: ID: 612845 Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 619230 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619260 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619655 Firmwareupdate of X2XLink module at POWERLINK Stations does not work since H4.34 Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming. Problem occurs on BC and SL: X20BC0083 X20cBC0083 < HW-Upgrade 2.2.0.0 X20BC1083 X20cBC1083 < HW-Upgrade 2.5.0.0 X20BC8083 X20cBC8083 < HW-Upgrade 2.5.0.0 X20BC8084 X20cBC8084 < HW-Upgrade 2.5.0.0 X20SL8101 X20cSL8101 X67BC81RT.L12 < HW-Upgrade 2.5.0.0 X67BC8321-1 X67BC8331 X67BC8513.L12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(426), 1\7735_3.fw(426), 1\7735_4.fw(210), 1\7735_5.fw(426) Version 2.5.6.0: ID: 603854 APROL: missing attribute for channel-parameter with "Sig_*" inserted Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(421), 1\7735_3.fw(421), 1\7735_4.fw(210), 1\7735_5.fw(421) Version 2.5.5.0: ID: 551145 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(421), 1\7735_3.fw(421), 1\7735_4.fw(210), 1\7735_5.fw(421) Version 2.5.4.0: ID: 540345 BC sporadically not going into Operationaldue to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(419), 1\7735_3.fw(419), 1\7735_4.fw(210), 1\7735_5.fw(419) Version 2.5.3.0: ID: 523560 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(417), 1\7735_3.fw(417), 1\7735_4.fw(210), 1\7735_5.fw(417) Version 2.5.2.0: ID: 493910 First POWERLINK UDP ASndSDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(415), 1\7735_3.fw(415), 1\7735_4.fw(210), 1\7735_5.fw(415) Version 2.5.0.0: ID: 468175 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468180 X2X FW update of several X2Xmodules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468185 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468570 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7735_1.fw(413), 1\7735_3.fw(413), 1\7735_4.fw(210), 1\7735_5.fw(413) Version 2.2.1.0: ID: 463210 hwx adaption Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(411), 1\7735_3.fw(411), 1\7735_4.fw(210), 1\7735_5.fw(411) Version 2.2.0.0: ID: 460135 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460255 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(411), 1\7735_3.fw(411), 1\7735_4.fw(210), 1\7735_5.fw(411) Version 2.1.0.0: ID: 433395 New hardware variant Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439130 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439235 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(400), 1\7735_3.fw(400), 1\7735_4.fw(210), 1\7735_5.fw(400) Version 2.0.1.0: ID: 433395 New hardware variant Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(210), 1\7735_3.fw(210), 1\7735_4.fw(210), 1\7735_5.fw(310) Version 2.0.0.0: ID: 355460 Input Latch funktion works Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 390300 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(210), 1\7735_3.fw(210), 1\7735_4.fw(210) Version 1.3.4.0: ID: 310810 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311030 Expansion: Link- selector flag New datapoints: RedundancyFirstLinkState and RedundancySecondLinkState Channel descriptionchanged: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\7735_1.fw(168), 1\7735_3.fw(168) Version 1.3.3.0: ID: 305170 ACOPOSmulti with SafeMC, asynchronous communicationlost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(167), 1\7735_3.fw(167) Version 1.3.2.0: ID: 298995 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(165), 1\7735_3.fw(165) Version 1.3.1.0: ID: 289025 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(163), 1\7735_3.fw(163) Version 1.3.0.0: ID: 277185 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277755 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\7735_1.fw(160), 1\7735_3.fw(160) Version 1.2.0.0: ID: 246660 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 - support for Simulation device added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\7735_1.fw(152), 1\7735_3.fw(152) Version 1.0.8.0: ID: 218510 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(145) Version 1.0.7.0: ID: 214300 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did awarmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(144) Version 1.0.6.1: ID: 214050 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup afterconfiguration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(144) Version 1.0.6.0: ID: 210935 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks(A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(143) Version 1.0.5.0: ID: 209590 Extensions and Bugfixes - New ASICS will be set to 3mA output current (A&P 182905) - Optimization ofSDO communication (unnecessary acknowledges removed) - Support of commands ReadMultipleParameter / WriteMultipleParameter - NodeID assignment by digital inputs supported (NodeId 241 and 242) - Minor corrections certification - ASnd frames with unknown ServiceID could disturb the BC (only possible with 3rd party MN) - Access to not existing objects in OD could cause firmware crash - When running X2X cycle times <200 us the X2X Bus wasnot working correctly(A&P 190630) - When in state PREOP_2 no SoC is received for 10sec the BC will fall back in PREOP_1 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(142) Version 1.0.4.0: ID: 160527 New info-/diagnostic data points, new FW 1.41 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.41 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(141) Version 1.0.3.0: ID: 173300 Extensions and Bugfixes - Improvement of X2X Timings (Jitter reduced from 180ns to 20ns) (A&P167857 und 171987) - Optimizations for operation in 200us networks - 2 nodeswith the same node number generated disturbance on the network (A&P 166040) - Functions for a new firmware download mechanism implemented (A&P 168537) Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(138) Version 1.0.2.0: ID: 164670 Extensions - Extensions for operation with Safety Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(136) |
|||||
| Sürüm | Dil | İşletim sistemi | Tarih | Boyut | Tip | İndirme |
| 2.17.0.0 | * | 05/14/2025 | 3 MB | EXE | AS6_HW_X67BC8321-1.exe | |
| Açıklama |
V6.0 HW Upgrade (X67BC8321-1) Revision information X67BC8321-1 Version 2.17.0.0: ID: RKFY-9694 Added capability to disable FastLink Down detection In the event of interferences on the network cable, the active Fast Link Down Detection very quickly leads to a complete loss of the link and thus to a failure of all subsequent stations. The Fast Link Down Detection can now be deactivated, which means that minor faults on the cable have less impact. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\7735_1.fw(438),1\7735_3.fw(438), 1\7735_5.fw(438) Version 2.15.0.0: ID: 758840 Optimization of asynchronous register access Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(433), 1\7735_3.fw(433), 1\7735_5.fw(433) Version 2.14.0.0: ID: 737320 NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 737325 POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438) POWERLINK Security Vulnerability (CVE-2020-13987) The POWERLINK IP stack was affected by a security vulnerability impacting thechecksum calculationof TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IP stack was affected by a security vulnerability impacting fragmented packet reassembly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 739450 Module documentation revised Data sheet V3.10 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(432), 1\7735_3.fw(432), 1\7735_5.fw(432) Version 2.11.1.0: ID: 697880 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7735_1.fw(430), 1\7735_3.fw(430), 1\7735_4.fw(210), 1\7735_5.fw(430) Version 2.11.0.0: ID: 664415 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 664455 DNA: Hub of PLK BC active until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665780 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665870 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(430), 1\7735_3.fw(430), 1\7735_4.fw(210), 1\7735_5.fw(430) Version 2.10.0.0: ID: 628740 Timing optimizations for hardware variants 1 and 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(428), 1\7735_3.fw(428), 1\7735_4.fw(210), 1\7735_5.fw(428) Version 2.9.3.0: ID: 639720 Alignment of AS output according to the FieldBusDesigner Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7735_1.fw(427), 1\7735_3.fw(427), 1\7735_4.fw(210), 1\7735_5.fw(427) Version 2.9.0.0: ID: 629040 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629105 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629185 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629250 Optimization of hub behavior Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(427), 1\7735_3.fw(427), 1\7735_4.fw(210), 1\7735_5.fw(427) Version 2.8.0.0: ID: 612845 Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 619230 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619260 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619655 Firmwareupdate of X2XLinkmodule at POWERLINK Stations does not work since H4.34 Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming. Problem occurs on BC and SL: X20BC0083 X20cBC0083 < HW-Upgrade 2.2.0.0 X20BC1083 X20cBC1083 < HW-Upgrade 2.5.0.0 X20BC8083 X20cBC8083 < HW-Upgrade 2.5.0.0 X20BC8084 X20cBC8084 < HW-Upgrade 2.5.0.0 X20SL8101 X20cSL8101 X67BC81RT.L12 < HW-Upgrade 2.5.0.0 X67BC8321-1 X67BC8331 X67BC8513.L12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(426), 1\7735_3.fw(426), 1\7735_4.fw(210), 1\7735_5.fw(426) Version 2.5.6.0: ID: 603854 APROL: missing attribute for channel-parameter with "Sig_*" inserted Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(421), 1\7735_3.fw(421), 1\7735_4.fw(210), 1\7735_5.fw(421) Version 2.5.5.0: ID: 551145 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(421), 1\7735_3.fw(421), 1\7735_4.fw(210), 1\7735_5.fw(421) Version 2.5.4.0: ID: 540345 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(419), 1\7735_3.fw(419),1\7735_4.fw(210), 1\7735_5.fw(419) Version 2.5.3.0: ID: 523560 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(417), 1\7735_3.fw(417), 1\7735_4.fw(210), 1\7735_5.fw(417) Version 2.5.2.0: ID: 493910 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(415), 1\7735_3.fw(415), 1\7735_4.fw(210), 1\7735_5.fw(415) Version 2.5.0.0: ID: 468175 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:468180 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468185 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468570 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7735_1.fw(413), 1\7735_3.fw(413), 1\7735_4.fw(210), 1\7735_5.fw(413) Version 2.2.1.0: ID: 463210 hwx adaption Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(411), 1\7735_3.fw(411), 1\7735_4.fw(210), 1\7735_5.fw(411) Version 2.2.0.0: ID: 460135 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460255 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPUPowerCycle wenn SLXhinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(411), 1\7735_3.fw(411), 1\7735_4.fw(210), 1\7735_5.fw(411) Version 2.1.0.0: ID: 433395 New hardware variant Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439130 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439235 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(400), 1\7735_3.fw(400), 1\7735_4.fw(210), 1\7735_5.fw(400) Version 2.0.1.0: ID: 433395 New hardware variant Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(210), 1\7735_3.fw(210), 1\7735_4.fw(210), 1\7735_5.fw(310) Version 2.0.0.0: ID: 355460 Input Latch funktion works Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 390300 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(210), 1\7735_3.fw(210), 1\7735_4.fw(210) Version 1.3.4.0: ID: 310810 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311030 Expansion: Link- selector flag New datapoints: RedundancyFirstLinkState and RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\7735_1.fw(168), 1\7735_3.fw(168) Version 1.3.3.0: ID: 305170 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high loadon the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(167), 1\7735_3.fw(167) Version 1.3.2.0: ID: 298995 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(165), 1\7735_3.fw(165) Version 1.3.1.0: ID: 289025 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(163), 1\7735_3.fw(163) Version 1.3.0.0: ID: 277185 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 277755 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed:Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\7735_1.fw(160), 1\7735_3.fw(160) Version 1.2.0.0: ID: 246660 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of moduleswith big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 - support for Simulation device added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\7735_1.fw(152), 1\7735_3.fw(152) Version 1.0.8.0: ID: 218510 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(145) Version 1.0.7.0: ID: 214300 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessedfasterthan allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(144) Version 1.0.6.1: ID: 214050 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(144) Version 1.0.6.0: ID: 210935 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(143) Version 1.0.5.0: ID: 209590 Extensions and Bugfixes - New ASICS will be set to 3mA output current (A&P 182905) - Optimization of SDO communication (unnecessary acknowledges removed) - Support of commands ReadMultipleParameter / WriteMultipleParameter - NodeID assignment by digital inputs supported (NodeId 241 and 242) - Minor corrections certification - ASnd frames with unknown ServiceID could disturb the BC (only possible with 3rd party MN) - Access to not existing objects in OD could cause firmware crash - When running X2X cycle times <200 us the X2X Bus was not working correctly (A&P 190630) - When in state PREOP_2 no SoC is received for 10sec the BC will fall backin PREOP_1 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(142) Version 1.0.4.0: ID: 160527 New info-/diagnostic data points, new FW 1.41 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.41 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(141) Version 1.0.3.0: ID: 173300 Extensions and Bugfixes - Improvement of X2X Timings (Jitter reduced from 180ns to 20ns) (A&P167857 und 171987) - Optimizations for operation in 200us networks - 2 nodes with the same node number generated disturbance on the network (A&P 166040) - Functions for a new firmware download mechanism implemented (A&P 168537) Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(138) Version 1.0.2.0: ID: 164670 Extensions - Extensions for operation with Safety Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(136) |
|||||