DWL@DWL10000791390

Sürüm Dil
İşletim sistemi
Tarih
Boyut
Tip İndirme
3.0.2.0 * 12/15/2025 482 KB EXE AS6_HW_X20SO2530.exe
Açıklama V6.0 HW Upgrade (X20SO2530)

Revision information X20SO2530

Version 3.0.2.0:

ID: FUVI-12370
Input channels removed in output only relay modules
Input channels removed in firmware and configuration of output only relay modules.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: FUVI-12314
Switch-on counter added for relay output channels
Switch-on counter added for relay output channels. The counter value can beread out with non cyclical channels.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: FUVI-12000
Improved bootup behavior
Fixed stability issues; faster bootup
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\56669_1.fw(652)

Version 3.0.0.0:

ID: FUVI-11178
Control of the outputs reworked
Control of the outputs reworked
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: FUVI-11177
New data sheet V3.0.0
New data sheet V3.0.0
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: FUVI-11176
First official release for Safety+
First official release for Safety+
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56669_1.fw(650)

Version 2.6.1.0:

ID: QCAS-240
Test pulse generation and evaluation process corrected
The time sequence for test pulse generation and evaluation has been revised. Channels are acknowledged simultaneously after a short circuit, there is no discrepancy error.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\56669_1.fw(581)

Version 2.6.0.0:

ID:780130
Correction of the input filter with set "Filter off".
Correction of the input filter, if a "Filter off" is set and a channel error is detected.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 780255
New data sheet V2.20
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 780375
Configuration for Power Calculation available
The Configuration for Power Calculation is now available in Automation Studio
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 10\56669_1.fw(580)

Version 2.5.0.0:

ID: 719780
Failsafe at every boot
It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crcdata is not equal to sent crc data"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID:726645
The power calculation of the modules is supported
The data for the power calculation of the data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 727175
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56669_1.fw(575)

Version 2.4.1.0:

ID: 692335
Support of the DYNlink interface
The DYNlink interface is supportedby the safe inputs.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 692375
The OSDD signal at the pulse output is corrected.
The OSDD signal at the pulse output is output correctly even when not in use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 696545
New data sheet V2.08
For changes see chapter"Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID:706290
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring of module cycle time and slot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\56669_1.fw(574)

Version 2.3.0.0:

ID: 670525
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 689660
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689730
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689965
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690120
New data sheet V2.06
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: No
Firmware: 10\56669_1.fw(572)

Version 2.1.0.0:

ID: 644195
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\56669_1.fw(570)

Version 1.10.10.1:

ID: 643300
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time hasbeen updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 7\56669_1.fw(331)

Version 1.10.10.0:

ID: 622745
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 7\56669_1.fw(331)

Version 1.10.9.0:

ID: 618180
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 7\56669_1.fw(330)

Version 1.10.1.0:

ID: 533180
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 549945
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 553740
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 570630
set SafeOutputOKs even when channel is not mapped
SafeOutputOKs are set now even when channel is not mapped
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 7\56669_1.fw(325)

Version 1.10.0.6:

ID: 533010
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 533095
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 7\56669_1.fw(320)

Version 1.10.0.2:

ID: 482605
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 7\56669_1.fw(320)

Version 1.10.0.0:

ID: 482605
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 7\56669_1.fw(320)
Sürüm Dil
İşletim sistemi
Tarih
Boyut
Tip İndirme
3.0.0.0 * 07/25/2025 782 KB EXE AS6_HW_X20SO2530.exe
Açıklama V6.0 HW Upgrade (X20SO2530)

Revision information X20SO2530

Version 3.0.0.0:

ID: FUVI-11178
Control of the outputs reworked
Control of the outputs reworked
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: FUVI-11177
New data sheet V3.0.0
New data sheet V3.0.0
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: FUVI-11176
First official release for Safety+
First official release for Safety+
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56710_1.fw(650)

Version 2.6.0.0:

ID: 783560
Configuration for Power Calculation available
The Configuration for Power Calculation is now available in Automation Studio
Channel description changed:No
Configuration description changed: Yes
Firmware changed: No

ID: 784570
New data sheet V2.20
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56710_1.fw(580)

Version 2.5.0.0:

ID: 719785
Failsafe at every boot
It could happen under rare conditions that the module is stuck infailsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 726650
The power calculation of the modules is supported
The data for the power calculation of the data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 727180
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56710_1.fw(575)

Version 2.4.1.0:

ID: 706300
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring of module cycle time and slot timeadjusted.
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes

ID: 706430
New data sheet V2.08
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56710_1.fw(574)

Version 2.3.0.0:

ID: 670530
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 688690
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689735
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689970
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690125
New data sheet V2.06
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56710_1.fw(572)

Version 2.1.0.0:

ID: 644200
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\56710_1.fw(570)

Version 1.10.10.1:

ID: 643455
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 7\56710_1.fw(331)

Version1.10.10.0:

ID: 622750
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 7\56710_1.fw(331)

Version 1.10.9.0:

ID: 618190
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 7\56710_1.fw(330)

Version 1.10.1.0:

ID: 543030
Improve the description section in the OSDD files
Improvethe description section in the OSDD files
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 570635
set SafeOutputOKs even when channel is not mapped
SafeOutputOKs are set now even when channel is not mapped
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes

ID: 582220
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 7\56710_1.fw(325)

Version 1.10.0.6:

ID: 543025
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 543035
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed:No

ID: 543040
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 7\56710_1.fw(320)

Version 1.10.0.2:

ID: 482610
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 7\56710_1.fw(320)

Version 1.10.0.0:

ID: 482610
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 7\56710_1.fw(320)
Sürüm Dil
İşletim sistemi
Tarih
Boyut
Tip İndirme
2.6.0.0 * 06/24/2024 2 MB EXE AS6_HW_X20SO2530.exe
Açıklama V6.0 HW Upgrade (X20SO2530)

Revision information X20SO2530

Version 2.6.0.0:

ID: 783570 / Support ID: 400412437
Configuration for Power Calculation available
The Configuration for Power Calculation isnow available in Automation Studio
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 10\53765_1.fw(580)

Version 2.5.0.0:

ID: 719790
Failsafeat every boot
It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 726675
The power calculation of the modules is supported
The data for the power calculation of the data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 727190
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\53765_1.fw(575)

Version 2.4.1.0:

ID: 706340
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring of module cycle time and slot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 706435
New data sheet V2.08
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\53765_1.fw(574)

Version 2.3.0.0:

ID: 668585
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 688735 / Support ID: 400299371
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689745
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689980
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed:No
Configuration description changed: No
Firmware changed: Yes

ID: 690135
New data sheet V2.06
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\53765_1.fw(572)

Version 2.1.0.0:

ID: 644205
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\53765_1.fw(570)

Version 1.10.10.1:

ID: 643460
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(331)

Version 1.10.10.0:

ID: 614390 / Support ID: 400257973
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes
Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(331)

Version 1.10.9.0:

ID: 618255
logger entry 112174, 108078
Logger entry 112174, 108078 could happensporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware:3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(330)

Version 1.10.0.6:

ID: 533080
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 533165
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID:533185
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320)

Version 1.10.0.2:

ID: 483060
Added coated type of module in help
Added coated type of module in help
Channel description changed:No
Configuration description changed: No
Firmware changed: No
Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320)

Version 1.10.0.1:

ID: 470595
Support of release 1.10 including openSAFETY 1.5
Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 470600
changed manual verion to 1.100
changed manual verion to 1.100
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320)

Version 1.9.0.0:

ID: 399900
Update Online Help
Update Online Help V1.90
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 413850
SafeModuleID >300
Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 413950
Channel-Status-Info ON
The default value of the Channel-Status information is now ON.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300)

Version 1.6.0.8:

ID: 388425
The module also supports SafetyRelease 1.8
Starting with this version, the module also supports SafetyRelease 1.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\53765_1.fw(291)

Version 1.6.0.7:

ID: 339270
internal Adjustments
internal Adjustments
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\53765_1.fw(291)

Version 1.6.0.5:

ID: 335455
The module also supports SafetyRelease 1.7
Starting with this version, the module also supports SafetyRelease 1.7
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 335460 / Support ID: 400083263
unlock of SafeModule IDs > 300
SafeModule IDs up to 1023 are now unlocked
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\53765_1.fw(291)

Version 1.6.0.0:

ID: 314065
Adaption of module configuration file release 1.6
Adaption of module configuration file release 1.6
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 3\53765_1.fw(291)

Version 1.5.0.4:

ID: 303395
Support of AutomationStudio 4.0
Support of AutomationStudio 4.0
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\53765_1.fw(291)

Version 1.5.0.1:

ID: 294345
First Official Release
First Official Release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\53765_1.fw(291)
Loading