3.0.2.0 * 12/15/2025 493 KB EXE AS6_HW_X20SC2212.exe
Açıklama V6.0 HW Upgrade (X20SC2212)

Revision information X20SC2212

Version 3.0.2.0:

ID: FUVI-12000
Improved bootup behavior
Fixed stability issues; faster bootup
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\56733_1.fw(652)

Version 3.0.0.0:

ID: FUVI-11178
Control of the outputs reworked
Control of the outputs reworked
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: FUVI-11177
New data sheet V3.0.0
New data sheet V3.0.0
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: FUVI-11176
First official release for Safety+
First official release for Safety+
Channeldescription changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56733_1.fw(650)

Version 2.6.1.0:

ID: QCAS-240
Test pulse generation and evaluation process corrected
The time sequence for test pulse generation and evaluation has been revised. Channels are acknowledged simultaneously after a short circuit, there is no discrepancy error.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\56733_1.fw(581)

Version 2.6.0.0:

ID: 780125
Correction of the inputfilter with set "Filter off".
Correction of the input filter, if a "Filter off" is set and a channel error is detected.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 780250
New data sheet V2.20
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 780370
Configuration for Power Calculation available
The Configuration for Power Calculation is now available in Automation Studio
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 10\56733_1.fw(580)

Version 2.4.0.0:

ID: 719725
Failsafe at every boot
It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 726580
The power calculation of the modules is supported
The data for the power calculation of the datasheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 727105
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56733_1.fw(574)

Version 2.3.0.1:

ID: 692330
Support of the DYNlink interface
The DYNlink interface is supported by the safe inputs.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 692370
The OSDD signal at the pulse output iscorrected.
The OSDD signal at the pulse output is output correctly even when not in use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 696540
New data sheet V2.08
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed:No
Firmware changed: No

ID: 706285
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring of module cycle time and slot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\56733_1.fw(573)

Version 2.2.0.0:

ID: 670590
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 688680
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689685
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689885
Increased delay of external feedback error detection
Increased delay of external feedback error detection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689915
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689990
Improvement of the feedback diagnosis.
Improvement of the feedback diagnosis of the output.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690060
New data sheet V2.06
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56733_1.fw(571)

Version 2.1.0.0:

ID: 644275
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\56733_1.fw(570)

Version 1.10.10.0:

ID: 622785
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 5\56733_1.fw(301), 6\56733_1.fw(331)

Version 1.10.9.1:

ID: 643440
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 5\56733_1.fw(301), 6\56733_1.fw(330)

Version 1.10.9.0:

ID: 618175
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 5\56733_1.fw(301), 6\56733_1.fw(330)

Version 1.10.1.2:

ID: 549935
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 552675
Loggerentry on negativ edge of SafeModuleOK
If a negativ edge on SafeModuleOK is detected, a logger entry will be generated
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 553735
New default values
The default valuesfor "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 5\56733_1.fw(301), 6\56733_1.fw(326)

Version 1.10.0.6:

ID: 533020
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 533105
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 5\56733_1.fw(301), 6\56733_1.fw(320)

Version 1.10.0.1:

ID: 474325
Support of release 1.10 including openSAFETY 1.5
Supportof release 1.10 including openSAFETY 1.5 with easier parametrizationof timing parameters
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 474330
changed manual verion to 1.100
changed manual verion to 1.100
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 5\56733_1.fw(301), 6\56733_1.fw(320)

Version 1.9.1.1:

ID: 453175
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 5\56733_1.fw(301)
Sürüm Dil
İşletim sistemi
Tarih
Boyut
Tip İndirme
3.0.0.0 * 07/25/2025 793 KB EXE AS6_HW_X20SC2212.exe
Açıklama V6.0 HW Upgrade (X20SC2212)

Revision information X20SC2212

Version 3.0.0.0:

ID: FUVI-11178
Control of the outputs reworked
Control of the outputs reworked
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: FUVI-11177
New data sheet V3.0.0
New data sheet V3.0.0
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: FUVI-11176
First official release for Safety+
First official release for Safety+
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56733_1.fw(650)

Version 2.6.1.0:

ID: QCAS-240
Test pulse generation and evaluation process corrected
The time sequence for test pulse generation and evaluation has been revised. Channels are acknowledged simultaneously after a short circuit, there is no discrepancy error.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\56733_1.fw(581)

Version 2.6.0.0:

ID: 780125
Correction of the input filter with set "Filter off".
Correction of the input filter, if a "Filter off" is set and a channelerroris detected.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 780250
New data sheet V2.20
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 780370
Configuration for Power Calculation available
The Configuration for Power Calculation is nowavailable in Automation Studio
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 10\56733_1.fw(580)

Version 2.4.0.0:

ID: 719725
Failsafe at every boot
It could happen under rare conditions that the module is stuckin failsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849"Received crc data is not equal to sent crc data"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 726580
The power calculation of the modules is supported
The data for the power calculation of the data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 727105
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56733_1.fw(574)

Version 2.3.0.1:

ID: 692330
Support of the DYNlink interface
The DYNlink interface is supported by the safe inputs.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 692370
The OSDD signal at the pulse output is corrected.
The OSDD signal at the pulse output is output correctly even when not in use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 696540
New data sheet V2.08
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 706285
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring of module cycle time andslot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\56733_1.fw(573)

Version 2.2.0.0:

ID: 670590
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 688680
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689685
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689885
Increased delay of external feedback error detection
Increased delay of external feedback error detection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689915
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689990
Improvement of the feedback diagnosis.
Improvement of the feedback diagnosis of the output.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690060
New data sheet V2.06
For changes see chapter "Versionhistory" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56733_1.fw(571)

Version 2.1.0.0:

ID: 644275
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\56733_1.fw(570)

Version 1.10.10.0:

ID: 622785
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 5\56733_1.fw(301), 6\56733_1.fw(331)

Version 1.10.9.1:

ID: 643440
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed:No
Configuration description changed: No
Firmware changed: No
Firmware: 5\56733_1.fw(301), 6\56733_1.fw(330)

Version 1.10.9.0:

ID: 618175
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 5\56733_1.fw(301), 6\56733_1.fw(330)

Version 1.10.1.2:

ID: 549935
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 552675
Loggerentry on negativ edge of SafeModuleOK
If a negativ edge on SafeModuleOK is detected, a logger entry will be generated
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 553735
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 5\56733_1.fw(301), 6\56733_1.fw(326)

Version 1.10.0.6:

ID: 533020
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 533105
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 5\56733_1.fw(301), 6\56733_1.fw(320)

Version 1.10.0.1:

ID: 474325
Support of release 1.10 including openSAFETY 1.5
Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 474330
changed manual verion to 1.100
changed manual verion to 1.100
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 5\56733_1.fw(301), 6\56733_1.fw(320)

Version 1.9.1.1:

ID: 453175
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed:Yes
Firmware: 5\56733_1.fw(301)
Sürüm Dil
İşletim sistemi
Tarih
Boyut
Tip İndirme
2.6.1.0 * 03/04/2025 2 MB EXE AS6_HW_X20SC2212.exe
Açıklama V6.0 HW Upgrade (X20SC2212)

Revision information X20SC2212

Version 2.6.1.0:

ID: QCAS-240
Test pulse generation and evaluation process corrected
The time sequence for test pulse generation and evaluation has been revised. Channels are acknowledged simultaneously after a short circuit, there is no discrepancy error.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\48549_1.fw(581)

Version 2.6.0.0:

ID: 780140
Correction of the input filter with set "Filter off".
Correction of the input filter, if a "Filter off" is set and a channel error is detected.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 780260
New data sheet V2.20
For changessee chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 780385
Configuration for Power Calculation available
The Configuration for Power Calculation is now available in Automation Studio
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 10\48549_1.fw(580)

Version 2.4.0.0:

ID: 715235
Failsafe at every boot
It could happen under rare conditions that the module is stuck in failsafe state at every boot,generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 726600
The power calculation of the modules is supported
The data for the power calculation of the data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 727120
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\48549_1.fw(574)

Version 2.3.0.1:

ID: 692345
Support of the DYNlink interface
The DYNlink interface is supported by the safe inputs.
Channel description changed: No
Configuration description changed:Yes
Firmware changed: Yes

ID: 692385
The OSDD signal at the pulse output is corrected.
The OSDD signal at the pulse output is output correctly even when not in use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 696555
New data sheet V2.08
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 706315
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring of module cycle time and slot time adjusted.
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\48549_1.fw(573)

Version 2.2.0.0:

ID: 668545
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 688715
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689700
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689895
Increased delay of external feedback error detection
Increased delay of external feedbackerror detection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689930
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690000
Improvement of the feedback diagnosis.
Improvement of the feedback diagnosis of the output.
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes

ID: 690075
New data sheet V2.06
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\48549_1.fw(571)

Version 2.1.0.0:

ID: 644280
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmwarechanged: Yes
Firmware: 10\48549_1.fw(570)

Version 1.10.9.1:

ID: 643475
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 5\48549_1.fw(301), 6\48549_1.fw(330)

Version 1.10.9.0:

ID: 618215
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 5\48549_1.fw(301), 6\48549_1.fw(330)

Version 1.10.1.2:

ID: 541660
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 552660
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID:552665
Loggerentry on negativ edge of SafeModuleOK
If a negativ edge on SafeModuleOK is detected, a logger entry will be generated
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 5\48549_1.fw(301), 6\48549_1.fw(326)

Version 1.10.0.6:

ID: 533015
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed:No
Firmware changed: No

ID: 533100
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 5\48549_1.fw(301), 6\48549_1.fw(320)

Version 1.10.0.1:

ID: 470500
Support of release 1.10 including openSAFETY 1.5
Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 470505
changedmanual verion to 1.100
changed manual verion to 1.100
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 5\48549_1.fw(301), 6\48549_1.fw(320)

Version 1.9.1.0:

ID: 425430
change of input filter
The behaviour of the input filter has changed.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 425435
fw valid from SafetyRelease 1.2 on
The firmware is used for all SafetyReleases from 1.2 on.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 425440
Update Online Help
Update Online Help V1.91
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 5\48549_1.fw(301)

Version 1.9.0.0:

ID: 413810
SafeModuleID >300
Now it is possible to set SafeModuleID greater than300, like described in the AS-Help.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID:413915
Channel-Status-Info ON
The default value of the Channel-Status information is now ON.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 414215
parameter max. Switching Frequency removed
Parameter max. Switching Frequency has no meaning any more.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 414290
2-channel evaluation: additional information at warning
If warning "discrepancy time elapsed" appears for 2-channel evaluation, info0 will nowdisplay the chosen PLCopen FBK (equivalent or antivalent).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 414315
Update Online Help
Update Online HelpV1.90
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\48549_1.fw(290), 4\48549_1.fw(300)

Version 1.6.0.8:

ID: 388330
The module also supports SafetyRelease 1.8
Starting with this version, the module also supports SafetyRelease 1.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\48549_1.fw(290)

Version 1.6.0.7:

ID: 339220
internal Adjustments
internal Adjustments
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\48549_1.fw(290)

Version 1.6.0.5:

ID: 335305
The module also supportsSafetyRelease 1.7
Starting with this version, the module also supports SafetyRelease 1.7
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 335315
unlock of SafeModule IDs > 300
SafeModule IDs up to 1023 are now unlocked
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\48549_1.fw(290)

Version 1.6.0.0:

ID: 314165
Adaption of module configuration file release 1.6
Adaption of module configuration file release 1.6
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 3\48549_1.fw(290)

Version 1.5.0.4:

ID: 303350
Support of AutomationStudio 4.0
Support of AutomationStudio 4.0
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\48549_1.fw(290)

Version 1.5.0.2:

ID: 294895
corrected AutomationStudio Help
Correctionsin Automation Studio Help done
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\48549_1.fw(290)

Version 1.5.0.1:

ID: 283685
First OfficialRelease
First Official Release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\48549_1.fw(290)
Sürüm Dil
İşletim sistemi
Tarih
Boyut
Tip İndirme
2.6.0.0 * 03/05/2024 2 MB EXE AS6_HW_X20SC2212.exe
Açıklama V6.0 HW Upgrade (X20SC2212)

Revision information X20SC2212

Version 2.6.0.0:

ID: 780140
Correction of the input filter with set "Filter off".
Correction of the input filter, if a "Filter off" is set and a channel error is detected.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 780260
New data sheet V2.20
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 780385 / Support ID: 400412437
Configuration for Power Calculation available
The Configuration for Power Calculation is now available in Automation Studio
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 10\48549_1.fw(580)

Version 2.4.0.0:

ID: 715235
Failsafe at every boot
It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 726600
The power calculation of the modules is supported
The data for the power calculation of the data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID:727120
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\48549_1.fw(574)

Version 2.3.0.1:

ID: 692345
Support of the DYNlink interface
The DYNlink interface is supported by the safe inputs.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 692385
The OSDD signal at the pulse output is corrected.
The OSDD signal at the pulse output is output correctly even when not in use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 696555
New data sheet V2.08
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 706315
Limit values forthe module cycle time adjusted
The limit values for the calculation and monitoring of module cycle time and slot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\48549_1.fw(573)

Version 2.2.0.0:

ID: 668545
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 688715 / Support ID: 400299371
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration"is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689700
Propagation delay statistics
The Propagation delay statisticscan now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689895
Increased delay of external feedback error detection
Increased delay of external feedback error detection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689930
Improvement of the internal voltage monitoring.
Improvement of theinternal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690000
Improvement of the feedback diagnosis.
Improvement of the feedback diagnosis of the output.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690075
New data sheet V2.06
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\48549_1.fw(571)

Version 2.1.0.0:

ID: 644280
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\48549_1.fw(570)

Version 1.10.9.1:

ID: 643475
data sheet V1.141
See chapture "Versionhistory" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 5\48549_1.fw(301), 6\48549_1.fw(330)

Version 1.10.9.0:

ID: 618215
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically withlarge projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 5\48549_1.fw(301), 6\48549_1.fw(330)

Version 1.10.1.2:

ID: 541660
New default values
The default values for "Filter On" and "Discrepancy Time" havebeen modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 552660
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 552665
Loggerentry on negativ edge of SafeModuleOK
Ifa negativ edge on SafeModuleOK is detected, a logger entry will be generated
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 5\48549_1.fw(301), 6\48549_1.fw(326)

Version 1.10.0.6:

ID: 533015
Add blackout mode
Addblackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 533100
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 5\48549_1.fw(301), 6\48549_1.fw(320)

Version 1.10.0.1:

ID: 470500
Support of release 1.10 including openSAFETY 1.5
Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 470505
changed manual verion to 1.100
changed manual verion to 1.100
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 5\48549_1.fw(301), 6\48549_1.fw(320)

Version 1.9.1.0:

ID: 425430
change of input filter
Thebehaviour of the input filter has changed.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 425435
fw valid from SafetyRelease 1.2 on
The firmware is used for all SafetyReleases from 1.2 on.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 425440
Update Online Help
Update Online Help V1.91
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 5\48549_1.fw(301)

Version 1.9.0.0:

ID: 413810
SafeModuleID >300
Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 413915
Channel-Status-Info ON
The default value of the Channel-Status information is now ON.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 414215
parameter max. Switching Frequency removed
Parameter max.Switching Frequency has no meaning any more.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 414290
2-channel evaluation: additional information at warning
If warning "discrepancy time elapsed" appears for 2-channel evaluation, info0 will now display the chosen PLCopen FBK (equivalent or antivalent).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 414315
Update Online Help
Update Online Help V1.90
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\48549_1.fw(290), 4\48549_1.fw(300)

Version 1.6.0.8:

ID: 388330
The module also supports SafetyRelease 1.8
Starting with this version, the module also supports SafetyRelease 1.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\48549_1.fw(290)

Version 1.6.0.7:

ID: 339220
internal Adjustments
internal Adjustments
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware:3\48549_1.fw(290)

Version 1.6.0.5:

ID: 335305
The modulealso supports SafetyRelease 1.7
Starting with this version, the module also supports SafetyRelease 1.7
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 335315/ Support ID: 400083263
unlock of SafeModule IDs > 300
SafeModule IDs up to 1023 are now unlocked
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\48549_1.fw(290)

Version 1.6.0.0:

ID: 314165
Adaption of module configuration file release 1.6
Adaption of module configuration file release 1.6
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 3\48549_1.fw(290)

Version 1.5.0.4:

ID: 303350
Support of AutomationStudio 4.0
Support of AutomationStudio 4.0
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware:3\48549_1.fw(290)

Version 1.5.0.2:

ID: 294895
corrected AutomationStudio Help
Corrections in Automation Studio Help done
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\48549_1.fw(290)

Version 1.5.0.1:

ID: 283685
First Official Release
First Official Release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\48549_1.fw(290)