V6.0 HW Upgrade (80SD100XD.W044-01)

DWL@DWL10000848800

Sürüm Dil
İşletim sistemi
Tarih
Boyut
Tip İndirme
2.3.0.0 * 03/13/2026 1 MB EXE AS6_HW_80SD100XD.W044-01.exe
Açıklama V6.0 HW Upgrade (80SD100XD.W044-01)

Revision information 80SD100XD.W044-01

Version 2.3.0.0:

ID: TDYD-10598
Overtemperature error occurs when switching on the enable supply
The error occurs temporary after activating the enable.
The cause is the switch-on behavior of the reporting unit,
which has been improved by modifying the internal communicationprotocol.
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes
Firmware: 1\50790_3.fw(106), 1\50790_4.fw(106), 1\50790_5.fw(110)

Version 2.2.3.0:

ID: 726000
Evaluation of EncOk0X wrong with mapp Motion
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\50790_3.fw(106), 1\50790_4.fw(106), 1\50790_5.fw(106)

Version 2.2.2.0:

ID: 700590
Latch functionality could not be configured for the second axis.
If "StepCounter" was used for the second axis of a module, the parameters set for "Reference pulse edge" and "Reference pulse source" were not used. The latch functionality could not be used correctly.
The latch functionality can now be used as configured.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 703030
Function model names adapted
Uniform function model names for all stepper modules
Channel description changed:No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\50790_3.fw(106), 1\50790_4.fw(106), 1\50790_5.fw(106)

Version 2.2.1.0:

ID: 669410
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 671455
Support for mappMotion
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\50790_3.fw(106), 1\50790_4.fw(106),1\50790_5.fw(106)

Version 1.3.0.1:

ID: 474995
Motion Wizzard revised
In AS 4.x, the aged library "AsString" won’t be added to a AS project anymore. The "AsBrStr" will be used by the Motion instead.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\50790_3.fw(106), 1\50790_4.fw(106), 1\50790_5.fw(106)

Version 1.3.0.0:

ID: 473425
Error correctionin order to guard motor outputs against short to ground
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\50790_3.fw(106), 1\50790_4.fw(106), 1\50790_5.fw(106)

Version 1.2.0.0:

ID: 400845
Cycle time of MPGen edjustable
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 400900
Function model Ramp:new mode
Mode -120: Set home position
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 400985
Corrected a problem in HWX file
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 440580
Support for HW-Variant 4
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 440590
Corrected HWC entry
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\50790_3.fw(104), 1\50790_4.fw(104)

Version 1.0.0.0:

ID: 319050
Support for the module 80SD100XD.W044-01
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\50790_3.fw(14)