Please choose country and language

V4.0 HW Upgrade (8I64xxxxxxx.00x-1)

DWL@DWL10000222282

Version Language
Operating System
Date
Size
Type Download
1.3.9.1 * 01/30/2017 9 MB EXE AS4_HW_8I64xxxxxxx.00x-1.exe
Description V4.0 HW Upgrade (8I64xxxxxxx.00x-1)

Revision information 8I64xxxxxxx.00x-1

Version 1.3.9.1:

ID: 515925
Internal revision
File history corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.9.0:

ID: 466740
Function models renamed
no influence to technical behavior
Functions model "default" renamed to "Direct control"
Functions model "default (MotionConfiguration)" renamed to "ACP10SDC (MotionConfiguration)"
Channel description changed: Yes
Configuration description changed: No
Firmware changed:No

ID: 511480
Default values resored
Default parameter value for module supervision restored, in order to avoid problems during conversion of existing projects in future.
ATTENTION: If module was stored in an Automation Studio project using hardware file 1.3.8.5, ensure parameter module supervision to have the desired value after upgrading.

INFORMATION:
The demaged file V 1.3.8.5 was delivered by Automation Studio 4.2.5 bis 4.2.6(complete installation).
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.8.5:

ID: 380420 / SupportID: 400132814
View in System Designer revised
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 511590
Motion Wizzard revised
In AS 4.x, the aged library "AsString" won’t be added to a AS project anymore. The "AsBrStr" will be used by the Motion instead.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.8.1:

ID: 321155
General review of HW files
Missing texts/textparts in HW file for AS4.x restored.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 366700 / Support ID: 400126199
Using ACPi X64 with SGC-CPU in AS4
Adaption for Automation Studio4; Configuration parameters can be download, when ACPi is used with SGC cpu.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.8.0:

ID: 329805
Change filter settings at Counter02
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.6.0:

ID: 300120
Configuration Downloadparameters "on change" added
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.5.0:

ID: 276485 /Support ID: 400074496
Timeout of AsIOAccRead() on ACPi X64
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 291675
With the configuration "Download parameters = no" all inverter configurations will be retained now.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45284_2.fw(9), 1\45284_3.fw(9)

Version 1.3.4.0:

ID: 276790 / Support ID: 400077929
Inverter configuration optimized
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45284_2.fw(8), 1\45284_3.fw(8)

Version 1.3.3.0:

ID: 274200
After installationof Upgrade 1.3.2.0 RevInfo appears two times in help
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes
Firmware: 1\45284_2.fw(8), 1\45284_3.fw(8)

Version 1.3.2.0:

ID: 270825 / Support ID: 400074141
At startup a COF error could appear with version 1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(7), 1\45284_3.fw(7)

Version 1.3.1.0:

ID: 258760 / Support ID: 400065557
On 8I0IF109.200-1 with rev. B5 the relay does not work instandalone mode
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(5), 1\45284_3.fw(5)

Version 1.2.0.0:

ID: 246470 / Support ID: 400057134
The boottime of X64 takes 8-45 seconds
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\45284_2.fw(5), 1\45284_3.fw(5)

Version 1.1.0.2:

ID: 245955
Customer-specific expansion of hardware description file
This upgrade has no impact on the Automation Studio and the standard version of the FieldbusDESIGNER
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(4)

Version 1.0.5.0:

ID: 238280 / Support ID: 400049786 400049841 400050585 400051602 400052158 400054894
At startup a CFF error could appear
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(4), 1\45284_3.fw(4)

Version 1.0.0.0:

ID: 223865
Support for ACOPOSInverter X64
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(2)