Short description
Interfaces POWERLINK
System module CPU
General information
System requirements
Automation Studio 3.0.71 or later
Automation Runtime 2.95 or later
SafeDESIGNER 2.58 and later, up to 3.0
Safety Release 1.1 and later, up to 1.6
Cooling Fanless
Status indicators CPU function, POWERLINK, SafeKEY
Diagnostics
CPU function Yes, using LED status indicator
POWERLINK Yes, using LED status indicator
SafeKEY Yes, using LED status indicator
Power consumption 5.1 W
Certifications
CE Yes
UKCA Yes
Functional safety cULus FSPC E361559
Energy and industrial systems
Certified for functional safety
ANSI UL 1998:2013
Functional safety IEC 61508:2010, SIL 3
EN 62061:2005/A2:2015, SIL 3
EN ISO 13849-1:2015, Cat. 4 / PL e
IEC 61511:2004, SIL 3
Functional safety EN 50156-1:2004
ATEX Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X
UL cULus E115267
Industrial control equipment
HazLoc cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5
DNV Temperature: A (0 to 45°C)
Humidity: B (up to 100%)
Vibration: A (0.7 g)
EMC: B (bridge and open deck)
LR ENV1
KR Yes
ABS Yes
BV EC21B
Temperature: 5 - 45°C
Vibration: 0.7 g
EMC: Bridge and open deck
EAC Yes
KC Yes
Safety characteristics
EN ISO 13849-1:2015
Category Cat. 4
PL PL e
DC >94%
MTTFD per channel 2500 years
Mission time Max. 20 years
IEC 61508:2010,
IEC 61511:2004,
EN 62061:2013
SIL CL SIL 3
SFF >90%
PFH / PFHd
Module <1*10-10
openSAFETY wired Negligible
openSAFETY wireless <1*10-14 * Number of openSAFETY packets per hour
PFD per channel <2*10-5
Proof test interval (PT) 20 years
Functionality
Number of supported safety nodes Max. 20
Communication with each other Communication only possible with SafeLOGIC controller SL8001 or SL8011
Support for machine options No
SafeMOTION support No
Shortest task class cycle time 1 ms
Fieldbus
Type POWERLINK
Variant Internal 2-port hub, 2x RJ45 shielded
Line length Max. 100 m between 2 stations (segment length)
Transfer rate 100 Mbit/s
Cycle time Max. 20 ms
Power supply
Nominal voltage 24 VDC -15% / +20%
Fuse Integrated, cannot be replaced
Reverse polarity protection Yes
Operating conditions
Mounting orientation
Horizontal Yes
Vertical Yes
Installation elevation above sea level 0 to 2000 m, no limitation
Degree of protection per EN 60529 IP20
Ambient conditions
Temperature
Operation
Horizontal mounting orientation 0 to 55°C
Vertical mounting orientation 0 to 45°C
Derating -
Storage -25 to 70°C
Transport -25 to 70°C
Relative humidity
Operation 5 to 95%, non-condensing
Storage 5 to 95%, non-condensing
Transport 5 to 95%, non-condensing
Mechanical properties
Note Order application memory (SafeKEY) separately.
X20 end cover plate (right) is included in delivery.
12-pin X20 terminal block, safety-keyed, is included in delivery.
SafeKEY cover is included in delivery.
Dimensions
Width 87.5+0.2 mm
Height 99 mm
Depth 75 mm
Weight 290 g
Materiaalnummer:
X20SL8000
Omschrijving:

SafeLOGIC controllers handle all central tasks within a safety-related application. Three different functional areas exist here. The configuration management system monitors the entire safety-related configuration of the application. When replacements are needed, the parameter management system makes sure that newly installed modules are assigned correct parameters that apply to the application. Lastly, SafeLOGIC handles the actual safety-related execution of the application program.

Vereiste toebehoren
Accessories
X20MK0201 X20 SafeKEY, 2 MB, for the X20SL80xx series
X20MK0203 X20 SafeKEY, 8 MB, for the X20SL80xx series
Automation Studio HW Upgrades Versie (Datum) Download
V3.0 HW Upgrade (X20SL8000) EXE / 7 MB
V3.0 HW Upgrade (X20SL8000) EXE / 7 MB
V4.0 HW Upgrade (X20SL8000) EXE / 7 MB
Certificaten Versie (Datum) Download
244665 CSA HazLoc CoC X20, X67 PDF / 158 KB
ABS Certificate of Product Design Assessment - X20 IO Series PDF / 2 MB
BV Type Approval Certificate - X20 PDF / 556 KB
DNV Type Approval Certificate - X20 PDF / 194 KB
E115267 UL CoC X20 PDF / 1 MB
FS Certificate SafeDESIGNER, SafeLOGIC, SafeIO PDF / 878 KB
FS EN 50156 Zertifikat SafeLOGIC, SafeIO PDF / 314 KB
FTZU 09 ATEX 0083X PDF / 771 KB
KR Type Approval Certificate MIL39390-AC003 (X20 System) PDF / 758 KB
Lloyds Register PDF / 502 KB
RINA Type Approval Certificate - X20 / Power Panel T30 PDF / 1 MB
X20, X67 KC certificates PDF / 6 MB
Documentatie Versie (Datum) Download
Datasheet X20SL80xx - Legacy PDF / 13 MB
information sheet SafeLOGIC PDF / 553 KB
E-CAD (Electro of EPLAN Templates) Versie (Datum) Download
X20 EPLAN P8 from V2.4 EXE / 160 MB
M-CAD (Mechan. Templates) Versie (Datum) Download
3D file STEP X20SL80xx ZIP / 65 KB
DXF File X20SL80xx ZIP / 8 KB
Dimensions PDF X20 CPU PDF / 48 KB
Tools / Hulpprogramma's / Voorbeelden Versie (Datum) Download
Sistema library ZIP / 336 KB

Graag land en taal kiezen