DWL@DWL10000297340

Versie Taal
Besturingssysteem
Datum
Grootte
Type Download
1.4.0.0 * 23-07-2021 5 MB EXE AS4_HW_X20cIF1063-1.exe
Omschrijving V4.0 HW Upgrade (X20cIF1063-1)

Revision information X20cIF1063-1

Version 1.4.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.3.1.0:

ID: 721870
Expansion: Operation behind an X20(c)EM* possible
The module can now also be operated on an X20(c)EM*
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\57909a1.fw(21), 1\57909_1.fw(13)

Version 1.3.0.0:

ID: 627930
Replacement of the interfacecard in AS
"Replace HW Modul" works correktly
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 703330
Firmware libraries updated to latest release.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57909a1.fw(21), 1\57909_1.fw(13)

Version 1.0.2.0:

ID: 466530
AddModulOK in I/O Mapping
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 466535
FDT/DTM Cycle Time change
Change parameter name "Cycle time [µs]" to "Data exchange time (CPU-netX) [µs]"
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\57909a1.fw(20), 1\57909_1.fw(12)

Version 1.0.1.0:

ID: 456755
Internal error 6999 when creating a project
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 456760
hwx-File Correction
Loading object in Hardware difference doesn't work, if Modul (X20IF1043-1) is placed in the Target
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57909a1.fw(20), 1\57909_1.fw(12)

Version 1.0.0.0:

ID: 342475
Support X20cIF1063-1
Support forAutomation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57909a1.fw(20), 1\57909_1.fw(12)
Versie Taal
Besturingssysteem
Datum
Grootte
Type Download
1.3.0.0 * 19-03-2021 5 MB EXE AS4_HW_X20cIF1063-1.exe
Omschrijving V4.0 HW Upgrade (X20cIF1063-1)

Revision information X20cIF1063-1-1

Version 1.3.0.0:

ID: 627930
Replacement of the interfacecardin AS
"Replace HW Modul" works correktly
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 703330
Firmware libraries updated to latest release.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57909a1.fw(21), 1\57909_1.fw(13)

Version 1.0.2.0:

ID: 466530
Add ModulOK in I/O Mapping
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 466535
FDT/DTM Cycle Time change
Change parameter name "Cycle time [µs]" to "Data exchange time (CPU-netX) [µs]"
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\57909a1.fw(20), 1\57909_1.fw(12)

Version 1.0.1.0:

ID: 456755
Internal error 6999 when creating a project
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 456760
hwx-File Correction
Loading object in Hardware difference doesn't work, if Modul (X20IF1043-1) is placed in the Target
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware:1\57909a1.fw(20), 1\57909_1.fw(12)

Version 1.0.0.0:

ID: 342475
Support X20cIF1063-1
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmwarechanged: No
Firmware: 1\57909a1.fw(20), 1\57909_1.fw(12)
Versie Taal
Besturingssysteem
Datum
Grootte
Type Download
1.0.2.0 * 19-02-2016 868 KB EXE AS4_HW_X20cIF1063-1.exe
Omschrijving V4.0 HW Upgrade (X20cIF1063-1)

Revision information X20cIF1063-1

Version 1.0.2.0:

ID: 466530
Add ModulOK in I/O Mapping
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 466535
FDT/DTM Cycle Time change
Change parameter name "Cycle time [µs]" to "Data exchange time (CPU-netX) [µs]"
Channel description changed: No
Configuration description changed:Yes
Firmware changed: No
Firmware: 1\57909a1.fw(20), 1\57909_1.fw(12)

Version 1.0.1.0:

ID: 456755
Internal error 6999 when creating a project
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 456760
hwx-File Correction
Loading object in Hardware difference doesn't work, if Modul(X20IF1043-1) is placed in the Target
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57909a1.fw(20), 1\57909_1.fw(12)

Version 1.0.0.0:

ID: 342475
Support X20cIF1063-1
Support for Automation Studio
Channeldescription changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57909a1.fw(20), 1\57909_1.fw(12)
Loading