DWL@DWL10000780015
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.5.1.0 | * | 08/05/2024 | 6 Mo | EXE | AS6_HW_X90CP174.48-S1.exe | |
Description |
V6.0 HW Upgrade (X90CP174.48-S1) Revision information X90CP174.48-S1 Version 1.5.1.0: ID: 786030 Enhancements for AS6/AR6 - configurable IpForwarding. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 2\60703_1.fp(54) Version 1.2.0.0: ID: 779390 Operating mode iCN on POWERLINK: spurious connection problem to the managerafter power fail corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 780695 Error in AB counter mode fixed. When a channel was configured as "Digital input source", the "Counter" Register was not reset to zero after reboot. Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 2\60703_1.fp(54) Version 1.1.3.0: ID: 761670 / Support ID: 400392864 X2X bus output cycle trigger error correction The X2X bus output cycle trigger was not started although it was configured. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 761730 / Support ID: 400249041 Register description of the sensor supply corrected Value "1" was stated as "not OK", which is incorrect Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 2\60703_1.fp(52) Version 1.1.2.0: ID: 743050 / Support ID: 400368170 Broadcast channels missing in PLK interface Due to the change to Powerlink type 6, the broadcast channels have to be included. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 2\60703_1.fp(52) Version 1.1.1.0: ID: 729155 Support for POWERLINK type 6 The module now supports POWERLINK type 6 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 729205 / Support ID: 400352024 Support for 6 A current on parallel channels When two 6 A channels are used in parallel mode, a total current of 12 A isnow possible. Attention: When using 4 A and 6 A channels in parallel, each channel can only supply 4 A. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 2\60703_1.fp(52) Version 1.1.0.0: ID: 704465 / Support ID: 400335624 DisableAB encoder on channel 2 when ABR is configured on channel 1. Channel description changed: No Configuration description changed: Yes Firmwarechanged: No ID: 717915 Enables second CPU core for I/O processing The I/O input processing can be assigned to the the second CPU core. This frees CPU processing power to be used by the application. Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 2\60703_1.fp(52) Version 1.0.4.0: ID: 694795 Support data point StorageWear, wear level of storage mediumstarting from AR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 694815 Support for automatic DNA configuration from AS 4.9.1 Channel descriptionchanged: No Configuration description changed: Yes Firmware changed: No Firmware: 2\60703_1.fp(52) Version 1.0.3.0: ID: 590240 First Version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 2\60703_1.fp(52) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.2.0.0 | * | 26/03/2024 | 6 Mo | EXE | AS6_HW_X90CP174.48-S1.exe | |
Description |
V6.0 HW Upgrade (X90CP174.48-S1) Revision information X90CP174.48-S1 Version 1.2.0.0: ID: 779390 Operating mode iCN on POWERLINK: spurious connection problem to the managerafter power fail corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 780695 Error in AB counter mode fixed. When a channel was configured as "Digital input source", the "Counter"Register was not reset to zero after reboot. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 2\60703_1.fp(54) Version 1.1.3.0: ID: 761670 / Support ID: 400392864 X2X bus output cycle trigger error correction TheX2X bus output cycle trigger was not started although it was configured. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 761730 / Support ID: 400249041 Register description of the sensor supply corrected Value "1" was stated as "not OK", which is incorrect Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 2\60703_1.fp(52) Version 1.1.2.0: ID: 743050 / Support ID: 400368170 Broadcast channels missing in PLK interface Due to the change to Powerlink type 6, the broadcast channels have to be included. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 2\60703_1.fp(52) Version 1.1.1.0: ID: 729155 Support for POWERLINK type 6 The module now supports POWERLINK type 6 Channel description changed: No Configuration descriptionchanged: Yes Firmware changed: No ID: 729205 / Support ID: 400352024 Support for 6 A current on parallel channels When two 6 A channels are used in parallel mode, a total current of 12 A isnow possible. Attention: When using 4 A and 6 A channels in parallel, each channel can only supply 4 A. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 2\60703_1.fp(52) Version 1.1.0.0: ID: 704465 / Support ID: 400335624 Disable AB encoder on channel 2 when ABR is configured on channel 1. Channel descriptionchanged: No Configuration description changed: Yes Firmware changed: No ID: 717915 Enables second CPU core for I/O processing The I/O input processing can be assigned to the the second CPU core. This frees CPU processing power to be used by the application. Channel descriptionchanged: Yes Configuration description changed: Yes Firmware changed: No Firmware: 2\60703_1.fp(52) Version 1.0.4.0: ID: 694795 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 694815 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 2\60703_1.fp(52) Version 1.0.3.0: ID: 590240 First Version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 2\60703_1.fp(52) |