DWL@DWL10000604624
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
2.5.0.0 | * | 09/06/2021 | 1 Mo | EXE | AS4_HW_X20SO6530.exe | |
Description |
V4.6 HW Upgrade (X20SO6530) Revision information X20SO6530 Version 2.5.0.0: ID: 715255 Failsafe at every boot It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data" Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 726680 The power calculation of the modules is supported The data for the power calculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 727195 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\61994_1.fw(575) Version 2.4.1.0: ID: 687505 / Support ID:400322122 EPLAN data created. EPLAN data for X20SO6530 newly created. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 706350 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 706410 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\61994_1.fw(574) Version 2.3.0.0: ID: 688745 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689750 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689985 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690140 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\61994_1.fw(572) Version 2.2.0.1: ID: 668595 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\61994_1.fw(571) Version 2.2.0.0: ID: 663405 / Support ID: 400302207 Automation Studio configuration changed Configuration changed for Automation Studio. Upgrade instalation only possible with mapp Safety. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665980 Switching delay changed Switching delay reduced to 20 ms if switching off. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\61994_1.fw(571) Version 2.1.0.0: ID: 644210 major (even incompatible) changes for mapp Safety Firstupgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\61994_1.fw(570) Version 1.10.1.3: ID: 643465 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 10\61994_1.fw(540) Version 1.10.1.2: ID: 607200 first official release first official release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\61994_1.fw(540) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.4.1.0 | * | 01/12/2020 | 1 Mo | EXE | AS4_HW_X20SO6530.exe | |
Description |
V4.6 HW Upgrade (X20SO6530) Revision information X20SO6530 Version 2.4.1.0: ID: 687505 / Support ID: 400322122 EPLAN data created. EPLAN data for X20SO6530 newly created. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 706350 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 706410 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\61994_1.fw(574) Version 2.3.0.0: ID: 688745 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689750 Propagation delay statistics The Propagation delaystatistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689985 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690140 New data sheet V2.06 For changes see chapter "Version history" inthe data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\61994_1.fw(572) Version 2.2.0.1: ID: 668595 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\61994_1.fw(571) Version 2.2.0.0: ID: 663405 / Support ID: 400302207 Automation Studio configuration changed Configuration changed for Automation Studio.Upgrade instalation only possible with mapp Safety. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665980 Switching delay changed Switching delay reduced to 20 ms if switching off. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\61994_1.fw(571) Version 2.1.0.0: ID: 644210 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mappSafety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\61994_1.fw(570) Version 1.10.1.3: ID: 643465 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\61994_1.fw(540) Version 1.10.1.2: ID: 607200 first official release first official release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\61994_1.fw(540) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.3.0.0 | * | 21/07/2020 | 1 Mo | EXE | AS4_HW_X20SO6530.exe | |
Description |
V4.6 HW Upgrade (X20SO6530) Revision information X20SO6530 Version 2.3.0.0: ID: 688745 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689750 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689985 Improvement of the internal voltage monitoring. Improvement ofthe internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690140 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\61994_1.fw(572) Version 2.2.0.1: ID: 668595 Adaptations for AutomationStudio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\61994_1.fw(571) Version 2.2.0.0: ID: 663405 / Support ID: 400302207 Automation Studio configuration changed Configuration changed for Automation Studio. Upgrade instalation only possible with mapp Safety. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665980 Switching delay changed Switching delay reduced to 20 ms if switching off. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\61994_1.fw(571) Version 2.1.0.0: ID: 644210 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\61994_1.fw(570) Version 1.10.1.3: ID: 643465 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware:10\61994_1.fw(540) Version 1.10.1.2: ID: 607200 first official release first official release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\61994_1.fw(540) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.2.0.1 | * | 12/12/2019 | 1 Mo | EXE | AS4_HW_X20SO6530.exe | |
Description |
V4.6 HW Upgrade (X20SO6530) Revision information X20SO6530 Version 2.2.0.1: ID: 668595 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\61994_1.fw(571) Version 2.2.0.0: ID: 663405 / Support ID: 400302207 Automation Studio configuration changed Configuration changed for Automation Studio. Upgrade instalation only possible with mapp Safety. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665980 Switching delay changed Switching delay reduced to 20 ms if switching off. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\61994_1.fw(571) Version 2.1.0.0: ID: 644210 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\61994_1.fw(570) Version 1.10.1.3: ID: 643465 data sheet V1.141 See chapture"Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\61994_1.fw(540) Version 1.10.1.2: ID: 607200 first official release first official release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\61994_1.fw(540) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.1.0.0 | * | 05/07/2019 | 1,017 Ko | EXE | AS4_HW_X20SO6530.exe | |
Description |
V4.6 HW Upgrade (X20SO6530) Revision information X20SO6530 Version 2.1.0.0: ID: 644210 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\61994_1.fw(570) Version 1.10.1.3: ID: 643465 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\61994_1.fw(540) Version 1.10.1.2: ID: 607200 first official release first official release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\61994_1.fw(540) |