DWL@DWL10000604612

Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.6.0.0 * 05/03/2024 1 Mo EXE AS4_HW_X20cSC2432.exe
Description V4.6 HW Upgrade (X20cSC2432)

Revision information X20cSC2432

Version 2.6.0.0:

ID: 780130
Correction of the input filter with set "Filter off".
Correction of the input filter, if a "Filter off" is set and a channel error is detected.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 780255
New data sheet V2.20
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 780375 / Support ID: 400412437
Configuration for Power Calculation available
The Configuration for Power Calculation is now available in Automation Studio
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 10\56669_1.fw(580)

Version 2.5.0.0:

ID: 719780
Failsafe at every boot
It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 726645
The power calculation of the modules is supported
The data for the power calculation ofthe data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 727175
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56669_1.fw(575)

Version 2.4.1.0:

ID: 692335
Support of the DYNlink interface
The DYNlink interface is supported by the safe inputs.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 692375
The OSDD signal at the pulse output is corrected.
The OSDD signal at the pulse output is output correctly even when not in use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 696545
New data sheet V2.08
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: No

ID: 706290
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring of module cycle time and slot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\56669_1.fw(574)

Version 2.3.0.0:

ID: 670525
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 689660 / Support ID: 400299371
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689730
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689965
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configurationdescription changed: No
Firmware changed: Yes

ID: 690120
New data sheet V2.06
For changes see chapter "Version history" in the datasheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56669_1.fw(572)

Version 2.1.0.0:

ID: 644195
major (even incompatible) changes formapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\56669_1.fw(570)

Version 1.10.10.1:

ID: 643300
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 7\56669_1.fw(331)

Version 1.10.10.0:

ID: 622745
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 7\56669_1.fw(331)

Version 1.10.9.0:

ID: 618180
logger entry 112174, 108078
Loggerentry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 7\56669_1.fw(330)

Version 1.10.1.0:

ID: 533180
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 549945
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configurationdescription changed: No
Firmware changed: No

ID: 553740
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 570630
setSafeOutputOKs even when channel is not mapped
SafeOutputOKs are set now even when channel is not mapped
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 7\56669_1.fw(325)

Version 1.10.0.6:

ID: 533010
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 533095
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 7\56669_1.fw(320)

Version 1.10.0.2:

ID: 482605
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 7\56669_1.fw(320)

Version 1.10.0.0:

ID: 482605
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 7\56669_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.5.0.0 * 09/06/2021 1 Mo EXE AS4_HW_X20cSC2432.exe
Description V4.6 HW Upgrade (X20cSC2432)

Revision information X20cSC2432

Version 2.5.0.0:

ID: 719780
Failsafe at every boot
It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal crosscommunication error EPS" or -1073565945/-1073561849 "Received crc data is notequal to sent crc data"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 726645
The power calculation of the modules is supported
The data for the powercalculation of the data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 727175
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56669_1.fw(575)

Version 2.4.1.0:

ID: 692335
Support of the DYNlink interface
The DYNlink interface is supported by the safeinputs.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 692375
The OSDD signal at the pulse output is corrected.
The OSDD signal at the pulse output is output correctly even when not in use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 696545
New data sheet V2.08
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 706290
Limit values for the module cycle time adjusted
The limit values for thecalculation and monitoring of module cycle time andslot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\56669_1.fw(574)

Version 2.3.0.0:

ID: 670525
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 689660 / Support ID: 400299371
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689730
Propagation delay statistics
The Propagationdelay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689965
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690120
New data sheet V2.06
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configurationdescription changed: No
Firmware changed: No
Firmware: 10\56669_1.fw(572)

Version 2.1.0.0:

ID: 644195
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety"in help!
Channel description changed: Yes
Configuration descriptionchanged: Yes
Firmware changed: Yes
Firmware: 10\56669_1.fw(570)

Version 1.10.10.1:

ID: 643300
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 7\56669_1.fw(331)

Version 1.10.10.0:

ID: 622745
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 7\56669_1.fw(331)

Version 1.10.9.0:

ID: 618180
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 7\56669_1.fw(330)

Version 1.10.1.0:

ID: 533180
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 549945
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID:553740
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 570630
set SafeOutputOKs even when channel is not mapped
SafeOutputOKs are set now even when channel is not mapped
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 7\56669_1.fw(325)

Version 1.10.0.6:

ID: 533010
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 533095
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration descriptionchanged: No
Firmware changed: No
Firmware: 7\56669_1.fw(320)

Version 1.10.0.2:

ID: 482605
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 7\56669_1.fw(320)

Version 1.10.0.0:

ID: 482605
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 7\56669_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.4.1.0 * 01/12/2020 1 Mo EXE AS4_HW_X20cSC2432.exe
Description V4.6 HW Upgrade (X20cSC2432)

Revision information X20cSC2432

Version 2.4.1.0:

ID: 692335
Support of the DYNlink interface
The DYNlink interface is supported by the safe inputs.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 692375
The OSDD signal at the pulse output is corrected.
The OSDD signal at the pulse output is output correctly even when notin use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 696545
New data sheet V2.08
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 706290
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring of module cycle time and slot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\56669_1.fw(574)

Version 2.3.0.0:

ID: 670525
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 689660 / Support ID: 400299371
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer thanthe network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689730
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689965
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690120
New data sheet V2.06
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56669_1.fw(572)

Version 2.1.0.0:

ID: 644195
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\56669_1.fw(570)

Version 1.10.10.1:

ID: 643300
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 7\56669_1.fw(331)

Version 1.10.10.0:

ID: 622745
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 7\56669_1.fw(331)

Version 1.10.9.0:

ID: 618180
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 7\56669_1.fw(330)

Version 1.10.1.0:

ID: 533180
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 549945
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 553740
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 570630
set SafeOutputOKs even when channel is not mapped
SafeOutputOKs are set now even when channelis not mapped
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 7\56669_1.fw(325)

Version 1.10.0.6:

ID: 533010
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 533095
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 7\56669_1.fw(320)

Version 1.10.0.2:

ID: 482605
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 7\56669_1.fw(320)

Version 1.10.0.0:

ID: 482605
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 7\56669_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.3.0.0 * 21/07/2020 1 Mo EXE AS4_HW_X20cSC2432.exe
Description V4.6 HW Upgrade (X20cSC2432)

Revision information X20cSC2432

Version 2.3.0.0:

ID: 670525
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 689660 / Support ID: 400299371
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689730
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689965
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690120
New data sheet V2.06
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56669_1.fw(572)

Version 2.1.0.0:

ID: 644195
major (evenincompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\56669_1.fw(570)

Version 1.10.10.1:

ID: 643300
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 7\56669_1.fw(331)

Version 1.10.10.0:

ID: 622745
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 7\56669_1.fw(331)

Version 1.10.9.0:

ID: 618180
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically withlarge projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 7\56669_1.fw(330)

Version 1.10.1.0:

ID: 533180
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 549945
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 553740
New default values
The default values for "FilterOn" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 570630
set SafeOutputOKs even when channel is not mapped
SafeOutputOKs are set now even when channel is not mapped
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 7\56669_1.fw(325)

Version 1.10.0.6:

ID:533010
Add blackout mode
Add blackout mode
Channel descriptionchanged: Yes
Configuration description changed: No
Firmware changed: No

ID: 533095
New channel for ConnectionValid
New channelfor ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 7\56669_1.fw(320)

Version 1.10.0.2:

ID: 482605
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 7\56669_1.fw(320)

Version 1.10.0.0:

ID: 482605
first officialrelease
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 7\56669_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.1.0.0 * 05/07/2019 886 Ko EXE AS4_HW_X20cSC2432.exe
Description V4.6 HW Upgrade (X20cSC2432)

Revision information X20cSC2432

Version 2.1.0.0:

ID: 644195
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\56669_1.fw(570)

Version 1.10.10.1:

ID: 643300
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: No
Firmware: 7\56669_1.fw(331)

Version 1.10.10.0:

ID: 622745
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 7\56669_1.fw(331)

Version 1.10.9.0:

ID: 618180
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 7\56669_1.fw(330)

Version 1.10.1.0:

ID: 533180
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 549945
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 553740
Newdefault values
The default values for "Filter On" and "Discrepancy Time"have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 570630
set SafeOutputOKs even when channel is not mapped
SafeOutputOKs are set now even when channel is not mapped
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 7\56669_1.fw(325)

Version 1.10.0.6:

ID: 533010
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 533095
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 7\56669_1.fw(320)

Version 1.10.0.2:

ID: 482605
first official release
first official release
Channel description changed: Yes
Configuration description changed:Yes
Firmware changed: Yes
Firmware: 7\56669_1.fw(320)

Version 1.10.0.0:

ID: 482605
first official release
first official release
Channel description changed: Yes
Configuration descriptionchanged: Yes
Firmware changed: Yes
Firmware: 7\56669_1.fw(320)
Loading
Retour à la liste

Veuillez sélectionner un pays et une langue

B&R Logo