DWL@DWL10000604611
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
2.6.0.0 | * | 05/03/2024 | 2 Mo | EXE | AS4_HW_X20cSC2212.exe | |
Description |
V4.6 HW Upgrade (X20cSC2212) Revision information X20cSC2212 Version 2.6.0.0: ID: 780125 Correction of the input filter with set "Filter off". Correction of the input filter, if a "Filter off" is set and a channel error is detected. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 780250 New data sheet V2.20 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 780370 / Support ID: 400412437 Configuration for Power Calculation available The Configuration for Power Calculation is now available in Automation Studio Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\56733_1.fw(580) Version 2.4.0.0: ID: 719725 Failsafe at every boot It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data" Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 726580 The power calculation of the modules is supported The data for the power calculation ofthe data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 727105 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56733_1.fw(574) Version 2.3.0.1: ID: 692330 Support of the DYNlink interface The DYNlink interface is supported by the safe inputs. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 692370 The OSDD signal at the pulse output is corrected. The OSDD signal at the pulse output is output correctly even when not in use. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 696540 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration descriptionchanged: No Firmware changed: No ID: 706285 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\56733_1.fw(573) Version 2.2.0.0: ID: 670590 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688680 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689685 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689885 Increased delay of external feedback error detection Increased delay of external feedback error detection Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689915 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689990 Improvement of the feedback diagnosis. Improvement of the feedback diagnosis of the output. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690060 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56733_1.fw(571) Version 2.1.0.0: ID: 644275 major (even incompatible) changesfor mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\56733_1.fw(570) Version1.10.10.0: ID: 622785 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 5\56733_1.fw(301), 6\56733_1.fw(331) Version 1.10.9.1: ID: 643440 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\56733_1.fw(301), 6\56733_1.fw(330) Version 1.10.9.0: ID: 618175 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 5\56733_1.fw(301), 6\56733_1.fw(330) Version 1.10.1.2: ID: 549935 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 552675 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: No ID: 553735 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 5\56733_1.fw(301), 6\56733_1.fw(326) Version 1.10.0.6: ID: 533020 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533105 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 5\56733_1.fw(301), 6\56733_1.fw(320) Version 1.10.0.1: ID: 474325 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 474330 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 5\56733_1.fw(301), 6\56733_1.fw(320) Version 1.9.1.1: ID: 453175 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 5\56733_1.fw(301) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.4.0.0 | * | 09/06/2021 | 1 Mo | EXE | AS4_HW_X20cSC2212.exe | |
Description |
V4.6 HW Upgrade (X20cSC2212) Revision information X20cSC2212 Version 2.4.0.0: ID: 719725 Failsafe at every boot It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal crosscommunication error EPS" or -1073565945/-1073561849 "Received crc data is notequal to sent crc data" Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 726580 The power calculation of the modules is supported The data for the powercalculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 727105 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56733_1.fw(574) Version 2.3.0.1: ID: 692330 Support of the DYNlink interface The DYNlink interface is supported by the safeinputs. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 692370 The OSDD signal at the pulse output is corrected. The OSDD signal at the pulse output is output correctly even when not in use. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 696540 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 706285 Limit values for the module cycle time adjusted The limit values for thecalculation and monitoring of module cycle time andslot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\56733_1.fw(573) Version 2.2.0.0: ID: 670590 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688680 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689685 Propagation delay statistics The Propagationdelay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689885 Increased delay of external feedback error detection Increased delay of external feedback error detection Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689915 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689990 Improvement of the feedback diagnosis. Improvementof the feedback diagnosis of the output. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690060 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56733_1.fw(571) Version 2.1.0.0: ID: 644275 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\56733_1.fw(570) Version 1.10.10.0: ID: 622785 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 5\56733_1.fw(301), 6\56733_1.fw(331) Version 1.10.9.1: ID: 643440 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculationof Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\56733_1.fw(301), 6\56733_1.fw(330) Version 1.10.9.0: ID: 618175 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 5\56733_1.fw(301), 6\56733_1.fw(330) Version 1.10.1.2: ID: 549935 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 552675 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: No ID: 553735 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 5\56733_1.fw(301), 6\56733_1.fw(326) Version 1.10.0.6: ID: 533020 Add blackout mode Add blackout mode Channel description changed:Yes Configuration description changed: No Firmware changed: No ID: 533105 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 5\56733_1.fw(301), 6\56733_1.fw(320) Version 1.10.0.1: ID: 474325 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 474330 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\56733_1.fw(301), 6\56733_1.fw(320) Version 1.9.1.1: ID: 453175 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 5\56733_1.fw(301) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.3.0.1 | * | 01/12/2020 | 1 Mo | EXE | AS4_HW_X20cSC2212.exe | |
Description |
V4.6 HW Upgrade (X20cSC2212) Revision information X20cSC2212 Version 2.3.0.1: ID: 692330 Support of the DYNlink interface The DYNlink interface is supported by the safe inputs. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 692370 The OSDD signal at the pulse output is corrected. The OSDD signal at the pulse output is output correctly even when notin use. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 696540 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 706285 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\56733_1.fw(573) Version 2.2.0.0: ID: 670590 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688680 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer thanthe network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689685 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689885 Increased delay of external feedback error detection Increased delay of external feedback error detection Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689915 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689990 Improvement of the feedback diagnosis. Improvement of the feedback diagnosis of the output. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690060 New data sheetV2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56733_1.fw(571) Version 2.1.0.0: ID: 644275 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\56733_1.fw(570) Version 1.10.10.0: ID: 622785 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 5\56733_1.fw(301), 6\56733_1.fw(331) Version 1.10.9.1: ID: 643440 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 5\56733_1.fw(301), 6\56733_1.fw(330) Version 1.10.9.0: ID: 618175 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 5\56733_1.fw(301), 6\56733_1.fw(330) Version 1.10.1.2: ID: 549935 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 552675 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: No ID: 553735 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 5\56733_1.fw(301), 6\56733_1.fw(326) Version 1.10.0.6: ID: 533020 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533105 New channelfor ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 5\56733_1.fw(301), 6\56733_1.fw(320) Version 1.10.0.1: ID: 474325 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 474330 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\56733_1.fw(301), 6\56733_1.fw(320) Version 1.9.1.1: ID: 453175 first official release firstofficial release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 5\56733_1.fw(301) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.2.0.0 | * | 21/07/2020 | 1 Mo | EXE | AS4_HW_X20cSC2212.exe | |
Description |
V4.6 HW Upgrade (X20cSC2212) Revision information X20cSC2212 Version 2.2.0.0: ID: 670590 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688680 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689685 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689885 Increased delay of external feedback error detection Increased delay of external feedback error detection Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689915 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689990 Improvement of the feedback diagnosis. Improvement of the feedback diagnosis of the output. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690060 New data sheet V2.06 For changes see chapter"Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56733_1.fw(571) Version 2.1.0.0: ID: 644275 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\56733_1.fw(570) Version 1.10.10.0: ID: 622785 Sporadic errors114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 5\56733_1.fw(301), 6\56733_1.fw(331) Version 1.10.9.1: ID: 643440 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel descriptionchanged: No Configuration description changed: No Firmware changed:No Firmware: 5\56733_1.fw(301), 6\56733_1.fw(330) Version 1.10.9.0: ID: 618175 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 5\56733_1.fw(301), 6\56733_1.fw(330) Version 1.10.1.2: ID: 549935 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 552675 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: No ID: 553735 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 5\56733_1.fw(301), 6\56733_1.fw(326) Version 1.10.0.6: ID: 533020 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533105 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 5\56733_1.fw(301), 6\56733_1.fw(320) Version 1.10.0.1: ID: 474325 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 474330 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\56733_1.fw(301), 6\56733_1.fw(320) Version 1.9.1.1: ID: 453175 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmwarechanged: Yes Firmware: 5\56733_1.fw(301) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.1.0.0 | * | 05/07/2019 | 919 Ko | EXE | AS4_HW_X20cSC2212.exe | |
Description |
V4.6 HW Upgrade (X20cSC2212) Revision information X20cSC2212 Version 2.1.0.0: ID: 644275 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\56733_1.fw(570) Version 1.10.10.0: ID: 622785 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 5\56733_1.fw(301), 6\56733_1.fw(331) Version 1.10.9.1: ID: 643440 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configurationdescription changed: No Firmware changed: No Firmware: 5\56733_1.fw(301), 6\56733_1.fw(330) Version 1.10.9.0: ID: 618175 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 5\56733_1.fw(301), 6\56733_1.fw(330) Version 1.10.1.2: ID: 549935 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmwarechanged: No ID: 552675 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will begenerated Channel description changed: No Configuration descriptionchanged: No Firmware changed: No ID: 553735 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 5\56733_1.fw(301), 6\56733_1.fw(326) Version 1.10.0.6: ID: 533020 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533105 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 5\56733_1.fw(301), 6\56733_1.fw(320) Version 1.10.0.1: ID: 474325 Support of release 1.10 includingopenSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 474330 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\56733_1.fw(301), 6\56733_1.fw(320) Version 1.9.1.1: ID: 453175 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 5\56733_1.fw(301) |