Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.0.3.0 | * | 20/11/2018 | 4 MB | EXE | AS4_HW_X90CP174.48-00.exe | |
Description |
V4.3 HW Upgrade (X90CP174.48-00) Revision information X90CP174.48-00 Version 1.0.3.0: ID: 588510 / Support ID: 400249457 Maximum total current added to documentation Channel description changed: No Configuration description changed: No Firmware changed: No ID: 589280 / Support ID: 400249041 I/O Data "SensorSupply" has been described Channel description changed: No Configuration description changed: No Firmware changed: No ID: 595655 / Support ID: 400248387 Documentation of analog inputs improved. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 609995 / Support ID: 400261388 Corrupted CAN messages on IF9 (CAN3) With heavy load on the processor interface a "race condition" may exist on the CAN control for IF9 (CAN3). As a result, the register access and the data access may interfere. For solving this "race condition" a locking mechanismhasbeen added, that allows data access to the CAN component only after the configuration via register accesses have been finished. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\60223_1.fp(24) Version 1.0.2.0: ID: 573905 Support X90CP174.48-00 Important remark: To use the help, a minimum version 4.3.5.24 of the Automation Studio Main Help is required. Otherwise the upgrade is installed, but the help pages are empty. In case you installed the upgrade in the wrong order, you must first uninstall the Main Help using the Windows Control Panel, install the Main Help again and then apply the Module Upgrade Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60223_1.fp(23) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.0.2.0 | * | 20/02/2018 | 4 MB | EXE | AS4_HW_X90CP174.48-00.exe | |
Description |
V4.3 HW Upgrade (X90CP174.48-00) Revision information X90CP174.48-00 Version 1.0.2.0: ID: 573905 Support X90CP174.48-00 Important remark: To use the help, a minimum version 4.3.5.24 of the Automation Studio Main Help is required. Otherwise the upgrade is installed, but the help pages are empty. In case you installed the upgrade in the wrong order, you must first uninstall the Main Help using the Windows Control Panel, install the Main Help again and then apply the Module Upgrade Channel description changed: Yes Configuration description changed: Yes Firmware changed:Yes Firmware: 1\60223_1.fp(23) |