DWL@DWL10000490993

Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.1.1.0 * 21/12/2020 251 Ko EXE AS4_HW_5PC900.TS17-01.exe
Description V4.3 HW Upgrade (5PC900.TS17-01)

Revision information 5PC900.TS17-01.TS17-01

Version 2.1.1.0:

ID: 711335
Preparation for hyperthreading expansions in the B&R Hypervisor from AS 4.10.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.1.0.0:

ID: 666960
Extensions Hypervisor from AR A4.81
USB allocation between GPOS and RTOS also possible on the Automation Panel.This requires that the appropriate hardware upgrades are usedfor all components (APC/PPC, AP, SDLx Receiver, SDLx Transmitter).
Starting with AS 4.8 following HWX upgrades (or newer) are recommended for APC910 + TS17 CPU, mixed operation of the current and older HWX upgrades is not recommended:
APC910 system unit: V2.1.0.0
5PC900.TS17-xx: V2.1.0.0
5AC901.LSD3-00: V2.0.0.0
5AC901.LSD4-00: V2.0.0.0
Automation Panels: V2.0.0.0
AP5000 extension unit: V2.0.0.0
Automation Panel SDLx Receiver: V2.0.0.0
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 666980
EPLAN Daten implemented
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.0.2.0:

ID: 603904
Enhancements for APROL
Channel description changed:Yes
Configuration description changed: Yes
Firmware changed: No

ID: 644425
Soft reset support for hypervisor target systems.
From version AR 4.71 an independent reboot of AR and GPOS is possible.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 644435
5LS182.8 can now be operated in slot 2 of a 5Slot APC910 with the B&RHypervisor.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.0.0.0:

ID: 566580
Preperation to support the B&R Hypervisor
The B&R Hypervisor is supported with Automation Studio version V4.4.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.1.0.0:

ID: 541675
Support for the Automation Runtime Embedded (ARemb)
The Intel Skylake CPUs are generally supported from Automation Studio 4.3.3and Automation Runtime Embedded A4.34.
For the support the usage of the latest version of the hardware upgrade of the system unit 5PC910.SX0x-00 is mandatory.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.0:

ID: 531155
Supportfor the Automation Runtime Windows (ARwin)
The Intel Skylake CPUs are generally supported from Automation Studio 4.3.3and Automation Runtime 4.33.
For the support the usage of the latest version of the hardware upgrade of the system unit 5PC910.SX0x-00 is mandatory.
Note: The support for the Automation Runtime Embedded (ARemb) will follow later.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.1.0.0 * 08/04/2020 252 Ko EXE AS4_HW_5PC900.TS17-01.exe
Description V4.3 HW Upgrade (5PC900.TS17-01)

Revision information 5PC900.TS17-00

Version 2.1.0.0:

ID: 666960
Extensions Hypervisor from AR A4.81
USB allocation between GPOS and RTOS also possible on the Automation Panel.This requires that the appropriate hardware upgrades are used for allcomponents (APC/PPC, AP, SDLx Receiver, SDLx Transmitter).
Starting with AS 4.8 following HWX upgrades (or newer) are recommended for APC910 + TS17 CPU,mixed operation of the current and older HWX upgrades is not recommended:
APC910 system unit: V2.1.0.0
5PC900.TS17-xx: V2.1.0.0
5AC901.LSD3-00: V2.0.0.0
5AC901.LSD4-00: V2.0.0.0
Automation Panels: V2.0.0.0
AP5000 extension unit: V2.0.0.0
Automation Panel SDLx Receiver: V2.0.0.0
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 666980
EPLAN Daten implemented
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.0.2.0:

ID: 603904
Enhancements for APROL
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

ID: 644425
Soft reset support for hypervisor target systems.
From version AR 4.71 an independent reboot of AR and GPOS is possible.
Channel description changed: No
Configuration description changed: Yes
Firmwarechanged: No

ID: 644435
5LS182.8 can now be operated in slot 2 of a 5Slot APC910 with the B&RHypervisor.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.0.1.0:

ID: 635080
Enhancements for AS V4.7
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.0.0.0:

ID: 566580
Preperationto support the B&R Hypervisor
The B&R Hypervisor is supported with Automation Studio version V4.4.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.1.0.0:

ID: 541675
Support for the Automation Runtime Embedded (ARemb)
The Intel Skylake CPUs are generally supported from Automation Studio 4.3.3and Automation Runtime Embedded A4.34.
For the support the usage of thelatest version of the hardware upgrade of thesystem unit 5PC910.SX0x-00 is mandatory.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.0:

ID: 531025
Support for the Automation Runtime Windows (ARwin)
The Intel Skylake CPUs are generally supported from Automation Studio 4.3.3and AutomationRuntime 4.33.
For the support the usage of the latest version of the hardware upgrade of the system unit 5PC910.SX0x-00 is mandatory.
Note: The support for the Automation Runtime Embedded (ARemb) will follow later.
Channeldescription changed: Yes
Configuration description changed: Yes
Firmware changed: No
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.0.2.0 * 27/05/2019 208 Ko EXE AS4_HW_5PC900.TS17-01.exe
Description V4.3 HW Upgrade (5PC900.TS17-01)

Revision information 5PC900.TS17-00

Version 2.0.2.0:

ID: 603904
Enhancements for APROL
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

ID: 644425
Soft reset support for hypervisor target systems.
From version AR 4.71 an independent reboot of AR and GPOS is possible.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 644435
5LS182.8 can now be operated in slot 2 of a 5Slot APC910 with the B&RHypervisor.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.0.1.0:

ID: 635080
Enhancements for AS V4.7
Channel description changed: No
Configurationdescription changed: Yes
Firmware changed: No

Version 2.0.0.0:

ID: 566580
Preperation to support the B&R Hypervisor
The B&R Hypervisor is supported with Automation Studio version V4.4.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.1.0.0:

ID: 541675
Support for the Automation Runtime Embedded (ARemb)
The Intel Skylake CPUs are generally supported from Automation Studio 4.3.3and Automation Runtime Embedded A4.34.
For the support the usage of the latest version of the hardware upgrade of the system unit 5PC910.SX0x-00 is mandatory.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.0:

ID: 531025
Support for the Automation RuntimeWindows (ARwin)
The Intel Skylake CPUs are generally supported from Automation Studio 4.3.3and Automation Runtime 4.33.
For the support the usage of the latest version of the hardware upgrade of the system unit 5PC910.SX0x-00 is mandatory.
Note: The support for the Automation Runtime Embedded (ARemb) will follow later.
Channel description changed: Yes
Configurationdescription changed: Yes
Firmware changed: No
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.0.0.0 * 28/11/2018 651 Ko EXE AS4_HW_5PC900.TS17-01.exe
Description V4.3 HW Upgrade (5PC900.TS17-01)

Revision information 5PC900.TS17-01

Version 2.0.0.0:

ID: 566580
Preperation to support the B&RHypervisor
The B&R Hypervisor is supported with Automation Studio version V4.4.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.1.0.0:

ID: 541675
Support for the Automation Runtime Embedded (ARemb)
The Intel Skylake CPUs are generally supported from Automation Studio 4.3.3and Automation Runtime Embedded A4.34.
For the support the usage of the latest version of the hardware upgrade of the system unit 5PC910.SX0x-00 is mandatory.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.0:

ID: 531155
Support for the Automation Runtime Windows (ARwin)
The Intel Skylake CPUs are generally supported from Automation Studio 4.3.3and Automation Runtime 4.33.
For the support the usage of the latest version of the hardware upgrade of the system unit 5PC910.SX0x-00 is mandatory.
Note: The support for the Automation Runtime Embedded (ARemb) will follow later.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
1.1.0.0 * 02/08/2017 640 Ko EXE AS4_HW_5PC900.TS17-01.exe
Description V4.3 HW Upgrade (5PC900.TS17-01)

Revision information 5PC900.TS17-00

Version 1.1.0.0:

ID: 541675
Support for the Automation Runtime Embedded (ARemb)
The Intel Skylake CPUs are generally supported fromAutomation Studio 4.3.3 and Automation Runtime Embedded A4.34.
For the support the usage of the latest version of the hardware upgrade of the system unit 5PC910.SX0x-00 is mandatory.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.0:

ID: 531025
Support for the Automation Runtime Windows (ARwin)
The Intel Skylake CPUs are generally supported from Automation Studio4.3.3 and Automation Runtime 4.33.
For the support the usage of the latestversion of the hardware upgrade of thesystem unit 5PC910.SX0x-00 is mandatory.
Note: The support for the Automation Runtime Embedded (ARemb) will follow later.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Loading
Retour à la liste

Veuillez sélectionner un pays et une langue

B&R Logo