DWL@DWL10000521666
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
2.0.0.0 | * | 14/09/2020 | 215 Ko | EXE | AS4_HW_5ACCLI02.SD40-000.exe | |
Description |
V4.3 HW Upgrade (5ACCLI02.SD40-000) Revision information 5ACCLI02.SD40-000 Version 2.0.0.0: ID: 678220 Extensions Hypervisor from AR A4.81 USB allocation between GPOS and RTOS also possible on the Automation Panel.This requires that the appropriate hardware upgrades are used for all components (APC/PPC, AP, SDLx Receiver, SDLx Transmitter) and a firmware upgrade of the used SDL4 components is necessary. Function is supported fromxPC3100 SDL4 Transmitters (SDL4T) FW V01.00, SDL4 Receiver (SDL4R) FW V06.14 and HDBaseT FW V01.00. Starting with AS 4.8 following HWX upgrades (or newer) are recommended for APC3100, mixed operation of the current and older HWX upgrades is not recommended: APC3100 system unit: V2.1.0.0 5ACCLI02.SD40-000: V2.0.0.0 AP1000 panels: V2.0.0.0 AP9x3 panels: V2.0.0.0 AP5000 panels: V2.0.0.0 AP5000 extension unit: V2.0.0.0 5DLSD4.1001-00: V2.0.0.0 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 678225 EPLAN Daten implemented Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 678265 Module supervision of the APC3100 Graphics option from AR A4.81: The supervision of the APC3100 Graphics option is activ from Automation Runtime version A4.81. In case of a missconfiguration or missing APC3100 Graphicsoption, the Automation PC is starting up in the service mode. This behavior can be configured via the configuration of the supervised option, the default is supervised = on. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 681995 Support for IOMapping starting with AS 4.8.2/AR A4.82. Channel description changed: Yes Configuration description changed: No Firmware changed: No Version 1.0.0.0: ID: 574885 Support for 5ACCLI02.SD40-000 To configure a SDL4 Panel following upgrades have to be installed, too: SDL4 Receiver: 5DLSD4.1001-00 V1.0.0.0 Automation Panel 9x3: 5AP9x3.xxxx-xx V1.7.0.0 Automation Panel 1000: 5AP11xx.xxxx-xx V1.3.0.0 Automation Panel 5000: 5AP5xxx.xxxx-xx V1.2.0.0 Channel description changed: No Configuration description changed:No Firmware changed: No |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.0.0.0 | * | 01/02/2018 | 385 Ko | EXE | AS4_HW_5ACCLI02.SD40-000.exe | |
Description |
V4.3 HW Upgrade (5ACCLI02.SD40-000) Revision information 5ACCLI02.SD40-000 Version 1.0.0.0: ID: 574885 Support for 5ACCLI02.SD40-000 To configure a SDL4 Panel following upgrades have to be installed, too: SDL4 Receiver: 5DLSD4.1001-00 V1.0.0.0 Automation Panel 9x3: 5AP9x3.xxxx-xx V1.7.0.0 Automation Panel 1000: 5AP11xx.xxxx-xx V1.3.0.0 Automation Panel 5000: 5AP5xxx.xxxx-xx V1.2.0.0 Channel description changed: No Configuration description changed: No Firmware changed: No |