V4.0 HW Upgrade (X67BC8513.L12) Revision information X67BC8513.L12 Version 2.15.0.0: ID: 758860 Optimization of asynchronous register access Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(433), 1\45996_3.fw(433), 1\46029_6.fw(832), 1\46029_7.fw(832) Version 2.14.1.0: ID: 737350 NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 737355 POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438) POWERLINK Security Vulnerability (CVE-2020-13987) The POWERLINK IP stack was affected by a security vulnerability impacting thechecksum calculation of TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IP stack was affected by a security vulnerability impacting fragmented packet reassembly. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(432), 1\45996_3.fw(432), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.11.1.0: ID: 697895 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_1.fw(430), 1\45996_3.fw(430), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.11.0.0: ID: 664425 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 664470 DNA: Hub of PLK BC active until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665805 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665885 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666170 Module documentation revised Data sheet V2.05 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\45996_1.fw(430), 1\45996_3.fw(430), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.9.3.0: ID: 639735 / Support ID: 400268096 Alignment of ASoutput according to the FieldBusDesigner Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_1.fw(427), 1\45996_3.fw(427), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.9.0.0: ID: 624520 L/A IF LED permanently green although Ethernet activity is taking place on the bus Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 625040 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629055 Ring redundancy: Cannot address the CNthat closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629130 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629225 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(427), 1\45996_3.fw(427), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.8.0.0: ID: 619245 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 619275 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619670 / Support ID: 400268920 Firmwareupdate of X2XLink module at POWERLINK Stations does not work since H4.34 Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming. Problem occurs on BC and SL: X20BC0083 X20cBC0083 < HW-Upgrade 2.2.0.0 X20BC1083 X20cBC1083 < HW-Upgrade 2.5.0.0 X20BC8083 X20cBC8083 < HW-Upgrade 2.5.0.0 X20BC8084 X20cBC8084 < HW-Upgrade 2.5.0.0 X20SL8101 X20cSL8101 X67BC81RT.L12 <HW-Upgrade 2.5.0.0 X67BC8321-1 X67BC8331 X67BC8513.L12 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 621725 / Support ID: 400264883 Display of further diagnostic data points in the I / O mapping of the X2X interface from theX67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\45996_1.fw(426), 1\45996_3.fw(426), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.5.0: ID: 551160 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(421), 1\45996_3.fw(421), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.4.0: ID: 540360 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(419), 1\45996_3.fw(419), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.3.0: ID: 523595 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(417), 1\45996_3.fw(417), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.2.0: ID: 493925 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(415), 1\45996_3.fw(415), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.0.0: ID: 468225 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468230 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468235 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468585 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_1.fw(413), 1\45996_3.fw(413), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.3.0.0: ID: 460150 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460270 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(411), 1\45996_3.fw(411), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.2.0.0: ID: 451510 / Support ID: 400167181 X67BC8513.L12 HW1 (Rev A5) boots from FW 152 only from bank 0 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(401), 1\45996_3.fw(401), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.1.0.0: ID: 439145 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439250 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\45996_1.fw(400), 1\45996_3.fw(400), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.0.1.0: ID: 410620 Missing I/O FW in Upgrade >= 2.0.0.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(300), 1\45996_3.fw(300), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.0.0.1: ID: 390315 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 393320 / Support ID: 400138511 X2X communication revised A new firmware for hardware variant 3 (BC-Part) was released. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(211), 1\45996_3.fw(211) Version 2.0.0.0: ID: 390315 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(210), 1\45996_3.fw(210) Version 1.3.4.3: ID: 305060 / Support ID: 400091367 Suppression of measurement peaks Suppression of measurement peaks after a fast rising or falling of the input signal. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 305190 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 310885 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311050/ Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed:Yes Firmware changed: No Firmware: 1\45996_3.fw(168), 1\46029_6.fw(818), 1\46029_7.fw(818) Version 1.3.3.0: ID: 299010 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_3.fw(165), 1\46029_6.fw(816), 1\46029_7.fw(816) Version 1.3.2.0: ID: 288295 Error correction gate time measurement on local I/O Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_3.fw(163), 1\46029_6.fw(816), 1\46029_7.fw(816) Version 1.3.1.0: ID: 277200 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277770 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\45996_3.fw(161), 1\46029_6.fw(800) Version 1.2.1.0: Firmware: 1\45996_1.fw(152), 1\45996_3.fw(153), 1\46029_6.fw(800) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.14.1.0 | * | 25/10/2021 | 2 Mo | EXE | AS4_HW_X67BC8513.L12.exe | |
Description |
V4.0 HW Upgrade (X67BC8513.L12) Revision information X67BC8513.L12 Version 2.14.1.0: ID: 737350 NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 737355 POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438) POWERLINK Security Vulnerability (CVE-2020-13987) The POWERLINKIP stack was affected by a security vulnerability impacting the checksum calculation of TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IP stack was affected by a security vulnerability impacting fragmented packet reassembly. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(432), 1\45996_3.fw(432), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.11.1.0: ID: 697895 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_1.fw(430), 1\45996_3.fw(430), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.11.0.0: ID: 664425 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 664470 DNA: Hub of PLK BC active until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665805 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665885 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666170 Module documentation revised Data sheet V2.05 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\45996_1.fw(430), 1\45996_3.fw(430), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.9.3.0: ID: 639735 / Support ID: 400268096 Alignment of AS output according to the FieldBusDesigner Channeldescription changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_1.fw(427), 1\45996_3.fw(427), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.9.0.0: ID: 624520 L/A IF LED permanently green although Ethernet activity is taking place on thebus Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 625040 Optimization of hubbehavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629055 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629130 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629225 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(427), 1\45996_3.fw(427), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.8.0.0: ID: 619245 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619275 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619670 / Support ID: 400268920 Firmwareupdate of X2XLink module at POWERLINK Stations does not work since H4.34 Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming. Problem occurs on BC and SL: X20BC0083 X20cBC0083 < HW-Upgrade 2.2.0.0 X20BC1083 X20cBC1083 < HW-Upgrade 2.5.0.0 X20BC8083 X20cBC8083 < HW-Upgrade2.5.0.0 X20BC8084 X20cBC8084 < HW-Upgrade 2.5.0.0 X20SL8101 X20cSL8101 X67BC81RT.L12 < HW-Upgrade 2.5.0.0 X67BC8321-1 X67BC8331 X67BC8513.L12 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No ID: 621725 / Support ID: 400264883 Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\45996_1.fw(426), 1\45996_3.fw(426), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.5.0: ID: 551160 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(421), 1\45996_3.fw(421), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.4.0: ID: 540360 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(419), 1\45996_3.fw(419), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.3.0: ID: 523595 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connectionvia UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(417), 1\45996_3.fw(417), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.2.0: ID:493925 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\45996_1.fw(415), 1\45996_3.fw(415), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.0.0: ID: 468225 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468230 /Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 468235 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468585 CiRsupport Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_1.fw(413), 1\45996_3.fw(413), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.3.0.0: ID: 460150 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 460270 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLXhinter BC Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 1\45996_1.fw(411), 1\45996_3.fw(411), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.2.0.0: ID: 451510 / Support ID: 400167181 X67BC8513.L12 HW1 (Rev A5) boots from FW 152 only from bank 0 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(401), 1\45996_3.fw(401), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.1.0.0: ID: 439145 / Support ID: 400150496 I/O modulesbehind POWERLINK bus controllers no longer achieving Operationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439250 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longerachieving Operationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(400), 1\45996_3.fw(400), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.0.1.0: ID: 410620 MissingI/O FW in Upgrade >= 2.0.0.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(300), 1\45996_3.fw(300), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.0.0.1: ID: 390315 / Support ID: 400129274 Uncommon X2Xsettings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 393320 / Support ID: 400138511 X2X communication revised A new firmware for hardware variant 3 (BC-Part) was released. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(211), 1\45996_3.fw(211) Version 2.0.0.0: ID: 390315 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(210), 1\45996_3.fw(210) Version 1.3.4.3: ID: 305060 / Support ID: 400091367 Suppression of measurement peaks Suppression of measurement peaks after a fast rising or falling of the input signal. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 305190 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 310885 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 311050 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_3.fw(168), 1\46029_6.fw(818), 1\46029_7.fw(818) Version 1.3.3.0: ID: 299010 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_3.fw(165), 1\46029_6.fw(816), 1\46029_7.fw(816) Version 1.3.2.0: ID: 288295 Error correction gate time measurement on local I/O Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_3.fw(163), 1\46029_6.fw(816), 1\46029_7.fw(816) Version 1.3.1.0: ID: 277200 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277770 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channeldescription changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\45996_3.fw(161), 1\46029_6.fw(800) Version 1.2.1.0: Firmware: 1\45996_1.fw(152), 1\45996_3.fw(153), 1\46029_6.fw(800) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.11.1.0 | * | 24/08/2020 | 2 Mo | EXE | AS4_HW_X67BC8513.L12.exe | |
Description |
V4.0 HW Upgrade (X67BC8513.L12) Revision information X67BC8513.L12 Version 2.11.1.0: ID: 697895 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configurationdescription changed: Yes Firmware changed: No Firmware: 1\45996_1.fw(430), 1\45996_3.fw(430), 1\46029_6.fw(819), 1\46029_7.fw(819) Version2.11.0.0: ID: 664425 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 664470 DNA: Hub of PLK BC active until first IDENT_REQUEST Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 665805 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665885 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 666170 Module documentation revised Data sheet V2.05 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\45996_1.fw(430), 1\45996_3.fw(430), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.9.3.0: ID: 639735 / Support ID: 400268096 Alignment of AS output according to the FieldBusDesigner Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_1.fw(427), 1\45996_3.fw(427), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.9.0.0: ID: 624520 L/A IF LED permanently green although Ethernet activity is taking place on the bus Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 625040 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629055 Ring redundancy:Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629130 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629225 Shortened preamble of Ethernetframe leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(427), 1\45996_3.fw(427), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.8.0.0: ID: 619245 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619275 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619670 / Support ID: 400268920 Firmwareupdate of X2XLink module at POWERLINK Stations does not work since H4.34 Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming. Problem occurs on BC and SL: X20BC0083 X20cBC0083 < HW-Upgrade 2.2.0.0 X20BC1083 X20cBC1083 < HW-Upgrade 2.5.0.0 X20BC8083 X20cBC8083 < HW-Upgrade 2.5.0.0 X20BC8084 X20cBC8084 < HW-Upgrade 2.5.0.0 X20SL8101 X20cSL8101 X67BC81RT.L12 < HW-Upgrade 2.5.0.0 X67BC8321-1 X67BC8331 X67BC8513.L12 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 621725 / Support ID: 400264883 Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\45996_1.fw(426), 1\45996_3.fw(426), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.5.0: ID: 551160 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(421), 1\45996_3.fw(421), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.4.0: ID: 540360 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(419), 1\45996_3.fw(419), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.3.0: ID: 523595 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(417), 1\45996_3.fw(417), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.2.0: ID: 493925 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(415), 1\45996_3.fw(415), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.0.0: ID: 468225 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468230 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468235 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are notinitialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468585 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_1.fw(413), 1\45996_3.fw(413), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.3.0.0: ID: 460150 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460270 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(411), 1\45996_3.fw(411), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.2.0.0: ID: 451510 / Support ID: 400167181 X67BC8513.L12 HW1 (Rev A5) boots from FW 152 only from bank 0 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(401), 1\45996_3.fw(401), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.1.0.0: ID: 439145 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439250 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(400), 1\45996_3.fw(400), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.0.1.0: ID: 410620 Missing I/O FW in Upgrade >= 2.0.0.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(300), 1\45996_3.fw(300), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.0.0.1: ID: 390315 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 393320 / Support ID: 400138511 X2X communication revised A new firmware for hardware variant 3 (BC-Part) was released. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(211), 1\45996_3.fw(211) Version 2.0.0.0: ID: 390315 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(210), 1\45996_3.fw(210) Version 1.3.4.3: ID: 305060 / Support ID: 400091367 Suppression of measurement peaks Suppression of measurement peaks after a fast rising or falling of the input signal. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 305190 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontrollerwas interrupted. Restarting the boscontroller restored communication. Loss ofasynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 310885 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored afterPowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311050 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_3.fw(168), 1\46029_6.fw(818), 1\46029_7.fw(818) Version 1.3.3.0: ID: 299010 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_3.fw(165), 1\46029_6.fw(816), 1\46029_7.fw(816) Version 1.3.2.0: ID: 288295 Error correction gate time measurement on local I/O Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_3.fw(163), 1\46029_6.fw(816),1\46029_7.fw(816) Version 1.3.1.0: ID: 277200 Support of'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277770 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\45996_3.fw(161), 1\46029_6.fw(800) Version 1.2.1.0: Firmware: 1\45996_1.fw(152), 1\45996_3.fw(153), 1\46029_6.fw(800) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.11.0.0 | * | 20/02/2020 | 2 Mo | EXE | AS4_HW_X67BC8513.L12.exe | |
Description |
V4.0 HW Upgrade (X67BC8513.L12) Revision information X67BC8513.L12 Version 2.11.0.0: ID: 664425 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 664470 DNA: Hub of PLK BCactive until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665805 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665885 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666170 Module documentation revised Data sheet V2.05 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\45996_1.fw(430), 1\45996_3.fw(430), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.9.3.0: ID: 639735 / Support ID: 400268096 Alignment of AS output according to the FieldBusDesigner Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_1.fw(427), 1\45996_3.fw(427),1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.9.0.0: ID: 624520 L/A IF LED permanently green although Ethernet activity is taking place on the bus Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 625040 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629055 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629130 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629225 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(427), 1\45996_3.fw(427), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.8.0.0: ID: 619245 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619275 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619670 / Support ID: 400268920 Firmwareupdate of X2XLink module at POWERLINK Stations does not work since H4.34 Since H4.34 the firmware update ofX2XLink modules connected to X67BC8321-1 did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming. Problem occurs on BC and SL: X20BC0083 X20cBC0083 < HW-Upgrade 2.2.0.0 X20BC1083 X20cBC1083 < HW-Upgrade 2.5.0.0 X20BC8083 X20cBC8083 < HW-Upgrade 2.5.0.0 X20BC8084 X20cBC8084 < HW-Upgrade 2.5.0.0 X20SL8101X20cSL8101 X67BC81RT.L12 < HW-Upgrade 2.5.0.0 X67BC8321-1 X67BC8331 X67BC8513.L12 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 621725 / Support ID: 400264883 Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed:No Firmware: 1\45996_1.fw(426), 1\45996_3.fw(426), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.5.0: ID: 551160 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(421), 1\45996_3.fw(421), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.4.0: ID: 540360 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(419), 1\45996_3.fw(419), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.3.0: ID: 523595 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(417), 1\45996_3.fw(417), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.2.0: ID: 493925 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(415), 1\45996_3.fw(415), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.0.0: ID: 468225 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:468230 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 468235 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468585 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_1.fw(413), 1\45996_3.fw(413), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.3.0.0: ID: 460150 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 460270 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCyclewenn SLXhinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(411), 1\45996_3.fw(411), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.2.0.0: ID: 451510 / Support ID: 400167181 X67BC8513.L12 HW1 (RevA5) boots from FW 152 only from bank 0 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(401), 1\45996_3.fw(401), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.1.0.0: ID: 439145 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439250 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(400), 1\45996_3.fw(400), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.0.1.0: ID: 410620 Missing I/O FW in Upgrade >= 2.0.0.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(300), 1\45996_3.fw(300), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.0.0.1: ID: 390315 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 393320 / Support ID: 400138511 X2X communication revised A new firmware for hardware variant 3 (BC-Part) was released. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(211), 1\45996_3.fw(211) Version 2.0.0.0: ID: 390315 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 1\45996_1.fw(210), 1\45996_3.fw(210) Version 1.3.4.3: ID: 305060 / Support ID: 400091367 Suppression of measurementpeaks Suppression of measurement peaks after a fast rising or falling ofthe inputsignal. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 305190 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 310885 / Support ID: 400097674 POWERLINKV1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 311050 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware:1\45996_3.fw(168), 1\46029_6.fw(818), 1\46029_7.fw(818) Version 1.3.3.0: ID: 299010 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_3.fw(165), 1\46029_6.fw(816), 1\46029_7.fw(816) Version 1.3.2.0: ID: 288295 Error correction gate time measurement on local I/O Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_3.fw(163), 1\46029_6.fw(816), 1\46029_7.fw(816) Version 1.3.1.0: ID: 277200 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277770 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\45996_3.fw(161), 1\46029_6.fw(800) Version 1.2.1.0: Firmware: 1\45996_1.fw(152), 1\45996_3.fw(153),1\46029_6.fw(800) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.9.3.0 | * | 12/04/2019 | 2 Mo | EXE | AS4_HW_X67BC8513.L12.exe | |
Description |
V4.0 HW Upgrade (X67BC8513.L12) Revision information X67BC8513.L12 Version 2.9.3.0: ID: 639735 / Support ID: 400268096 Alignment of AS output according to the FieldBusDesigner Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_1.fw(427), 1\45996_3.fw(427), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.9.0.0: ID: 624520 L/A IF LED permanently green although Ethernet activity is taking place on the bus Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 625040 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629055 Ring redundancy: Cannot addressthe CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629130 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629225 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\45996_1.fw(427), 1\45996_3.fw(427), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.8.0.0: ID: 619245 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619275 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619670 / Support ID: 400268920 Firmwareupdate of X2XLink module at POWERLINK Stations does not worksince H4.34 Since H4.34 the firmware update of X2XLink modules connectedto X67BC8321-1 did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming. Problem occurs on BC and SL: X20BC0083 X20cBC0083 < HW-Upgrade 2.2.0.0 X20BC1083 X20cBC1083 < HW-Upgrade 2.5.0.0 X20BC8083 X20cBC8083 < HW-Upgrade 2.5.0.0 X20BC8084 X20cBC8084 < HW-Upgrade 2.5.0.0 X20SL8101 X20cSL8101 X67BC81RT.L12 < HW-Upgrade 2.5.0.0 X67BC8321-1 X67BC8331 X67BC8513.L12 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 621725 / Support ID: 400264883 Displayof further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\45996_1.fw(426), 1\45996_3.fw(426), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.5.0: ID: 551160 Startup time optimizations Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(421), 1\45996_3.fw(421), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.4.0: ID: 540360 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(419), 1\45996_3.fw(419), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.3.0: ID: 523595 / Support ID: 400205694 safety modules notswitching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(417), 1\45996_3.fw(417), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.2.0: ID: 493925 / SupportID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(415), 1\45996_3.fw(415), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.0.0: ID: 468225 optimization of X2X FW updates Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 468230 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 468235 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.bySL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468585 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_1.fw(413), 1\45996_3.fw(413), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.3.0.0: ID: 460150 /Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 460270 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(411), 1\45996_3.fw(411), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.2.0.0: ID: 451510/ Support ID: 400167181 X67BC8513.L12 HW1 (Rev A5) boots from FW 152 only from bank 0 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(401), 1\45996_3.fw(401), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.1.0.0: ID: 439145 / Support ID: 400150496 I/O modules behind POWERLINKbus controllers no longer achieving Operationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439250 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(400), 1\45996_3.fw(400), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.0.1.0: ID: 410620 Missing I/O FW in Upgrade >= 2.0.0.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(300), 1\45996_3.fw(300), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.0.0.1: ID: 390315 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 393320 / Support ID: 400138511 X2X communication revised A new firmware for hardware variant 3 (BC-Part) was released. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(211), 1\45996_3.fw(211) Version 2.0.0.0: ID: 390315 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(210), 1\45996_3.fw(210) Version 1.3.4.3: ID: 305060 / Support ID: 400091367 Suppression of measurement peaks Suppression ofmeasurement peaks after a fast rising or falling of the inputsignal. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 305190 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 310885 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:311050 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_3.fw(168), 1\46029_6.fw(818), 1\46029_7.fw(818) Version 1.3.3.0: ID: 299010 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_3.fw(165), 1\46029_6.fw(816), 1\46029_7.fw(816) Version 1.3.2.0: ID: 288295 Error correction gate time measurement on local I/O Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_3.fw(163), 1\46029_6.fw(816), 1\46029_7.fw(816) Version 1.3.1.0: ID: 277200 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277770 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\45996_3.fw(161), 1\46029_6.fw(800) Version 1.2.1.0: Firmware: 1\45996_1.fw(152), 1\45996_3.fw(153), 1\46029_6.fw(800) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.9.0.0 | * | 13/03/2019 | 2 Mo | EXE | AS4_HW_X67BC8513.L12.exe | |
Description |
V4.0 HW Upgrade (X67BC8513.L12) Revision information X67BC8513.L12 Version 2.9.0.0: ID: 624520 L/A IF LED permanently green although Ethernet activity is taking place on the bus Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 625040 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629055 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629130 DNA: BC ashead-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629225 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(427), 1\45996_3.fw(427), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.8.0.0: ID: 619245 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619275 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619670 / Support ID: 400268920 Firmwareupdate of X2XLink module at POWERLINK Stations does not work since H4.34 Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming. Problem occurs on BC and SL: X20BC0083 X20cBC0083 < HW-Upgrade 2.2.0.0 X20BC1083 X20cBC1083 < HW-Upgrade 2.5.0.0 X20BC8083 X20cBC8083 < HW-Upgrade 2.5.0.0 X20BC8084 X20cBC8084< HW-Upgrade 2.5.0.0 X20SL8101 X20cSL8101 X67BC81RT.L12 < HW-Upgrade 2.5.0.0 X67BC8321-1 X67BC8331 X67BC8513.L12 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 621725 / Support ID: 400264883 Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 buscontroller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\45996_1.fw(426), 1\45996_3.fw(426), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.5.0: ID: 551160 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(421), 1\45996_3.fw(421), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.4.0: ID: 540360 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems atstartup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(419), 1\45996_3.fw(419), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.3.0: ID: 523595 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(417), 1\45996_3.fw(417), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.2.0: ID: 493925 / Support ID: 400103115,400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(415), 1\45996_3.fw(415), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.0.0: ID: 468225 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468230 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468235 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468585 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_1.fw(413), 1\45996_3.fw(413), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.3.0.0: ID: 460150 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460270 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(411), 1\45996_3.fw(411), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.2.0.0: ID: 451510 / Support ID: 400167181 X67BC8513.L12 HW1 (Rev A5) boots from FW 152 only from bank 0 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(401), 1\45996_3.fw(401), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.1.0.0: ID: 439145 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439250 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(400), 1\45996_3.fw(400), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.0.1.0: ID: 410620 Missing I/O FW in Upgrade >= 2.0.0.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(300), 1\45996_3.fw(300), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.0.0.1: ID: 390315 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 393320 / Support ID: 400138511 X2X communication revised A new firmware for hardware variant 3 (BC-Part) was released. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(211), 1\45996_3.fw(211) Version 2.0.0.0: ID: 390315/ Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(210), 1\45996_3.fw(210) Version 1.3.4.3: ID: 305060 / Support ID: 400091367 Suppression of measurement peaks Suppression of measurement peaks after a fast rising or falling of the input signal. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 305190 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU,asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 310885 /Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311050 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_3.fw(168), 1\46029_6.fw(818), 1\46029_7.fw(818) Version 1.3.3.0: ID: 299010 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_3.fw(165), 1\46029_6.fw(816), 1\46029_7.fw(816) Version 1.3.2.0: ID: 288295 Error correction gate time measurement on local I/O Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_3.fw(163), 1\46029_6.fw(816), 1\46029_7.fw(816) Version 1.3.1.0: ID: 277200 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277770 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\45996_3.fw(161), 1\46029_6.fw(800) Version 1.2.1.0: Firmware: 1\45996_1.fw(152), 1\45996_3.fw(153), 1\46029_6.fw(800) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.8.0.0 | * | 12/12/2018 | 2 Mo | EXE | AS4_HW_X67BC8513.L12.exe | |
Description |
V4.0 HW Upgrade (X67BC8513.L12) Revision information X67BC8513.L12 Version 2.8.0.0: ID: 619245 / Support ID: 400257683 DNA: PLKhub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619275 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619670 / Support ID: 400268920 Firmwareupdate of X2XLink module at POWERLINK Stations does not work since H4.34 Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollersthat have no explicit enable for streaming. Problem occurs on BC and SL: X20BC0083 X20cBC0083 < HW-Upgrade 2.2.0.0 X20BC1083 X20cBC1083 < HW-Upgrade 2.5.0.0 X20BC8083 X20cBC8083 < HW-Upgrade 2.5.0.0 X20BC8084 X20cBC8084 < HW-Upgrade 2.5.0.0 X20SL8101 X20cSL8101 X67BC81RT.L12 < HW-Upgrade 2.5.0.0 X67BC8321-1 X67BC8331 X67BC8513.L12 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 621725 / Support ID: 400264883 Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\45996_1.fw(426), 1\45996_3.fw(426), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.5.0: ID: 551160 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(421), 1\45996_3.fw(421), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.4.0: ID: 540360 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(419), 1\45996_3.fw(419), 1\46029_6.fw(819), 1\46029_7.fw(819) Version2.5.3.0: ID: 523595 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(417), 1\45996_3.fw(417), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.2.0: ID: 493925 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(415), 1\45996_3.fw(415), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.0.0: ID: 468225 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468230 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468235 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468585 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_1.fw(413), 1\45996_3.fw(413), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.3.0.0: ID: 460150 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460270 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(411), 1\45996_3.fw(411), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.2.0.0: ID: 451510 / Support ID: 400167181 X67BC8513.L12 HW1 (Rev A5) boots from FW 152 onlyfrom bank 0 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(401), 1\45996_3.fw(401), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.1.0.0: ID: 439145 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439250 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(400), 1\45996_3.fw(400), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.0.1.0: ID: 410620 Missing I/O FW in Upgrade>= 2.0.0.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(300), 1\45996_3.fw(300), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.0.0.1: ID: 390315 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 393320 / Support ID: 400138511 X2X communication revised A new firmware for hardware variant 3 (BC-Part) was released. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(211), 1\45996_3.fw(211) Version 2.0.0.0: ID: 390315 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(210), 1\45996_3.fw(210) Version 1.3.4.3: ID: 305060 / Support ID: 400091367 Suppression of measurement peaks Suppression of measurement peaks after a fast rising or falling of the input signal. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 305190 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 310885 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311050 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_3.fw(168), 1\46029_6.fw(818), 1\46029_7.fw(818) Version 1.3.3.0: ID: 299010 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_3.fw(165), 1\46029_6.fw(816), 1\46029_7.fw(816) Version 1.3.2.0: ID: 288295 Error correction gate time measurement on local I/O Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_3.fw(163), 1\46029_6.fw(816), 1\46029_7.fw(816) Version 1.3.1.0: ID: 277200 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277770 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\45996_3.fw(161), 1\46029_6.fw(800) Version 1.2.1.0: Firmware: 1\45996_1.fw(152), 1\45996_3.fw(153), 1\46029_6.fw(800) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.5.5.0 | * | 08/09/2017 | 2 Mo | EXE | AS4_HW_X67BC8513.L12.exe | |
Description |
V4.0 HW Upgrade (X67BC8513.L12) Revision information X67BC8513.L12 Version 2.5.5.0: ID: 551160 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(421), 1\45996_3.fw(421), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.4.0: ID: 540360 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(419), 1\45996_3.fw(419), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.3.0: ID: 523595 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(417), 1\45996_3.fw(417), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.2.0: ID: 493925 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(415), 1\45996_3.fw(415), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.5.0.0: ID: 468225 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468230 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468235 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 468585 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_1.fw(413), 1\45996_3.fw(413), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.3.0.0: ID: 460150 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460270 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(411), 1\45996_3.fw(411), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.2.0.0: ID:451510 / Support ID: 400167181 X67BC8513.L12 HW1 (Rev A5) boots from FW 152 only from bank 0 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(401), 1\45996_3.fw(401), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.1.0.0: ID: 439145 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439250 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achievingOperationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(400), 1\45996_3.fw(400), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.0.1.0: ID: 410620 Missing I/O FW inUpgrade >= 2.0.0.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_1.fw(300), 1\45996_3.fw(300), 1\46029_6.fw(819), 1\46029_7.fw(819) Version 2.0.0.1: ID: 390315 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 393320 / Support ID: 400138511 X2X communication revised A new firmware for hardware variant 3 (BC-Part) was released. Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 1\45996_1.fw(211), 1\45996_3.fw(211) Version 2.0.0.0: ID: 390315 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\45996_1.fw(210), 1\45996_3.fw(210) Version 1.3.4.3: ID: 305060 / Support ID: 400091367 Suppression of measurement peaks Suppression of measurement peaks after a fast rising or falling of the input signal. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 305190 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was ahigh load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 310885 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOnbeginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311050 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\45996_3.fw(168),1\46029_6.fw(818), 1\46029_7.fw(818) Version 1.3.3.0: ID: 299010 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_3.fw(165), 1\46029_6.fw(816), 1\46029_7.fw(816) Version 1.3.2.0: ID: 288295 Error correction gate time measurement on local I/O Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45996_3.fw(163), 1\46029_6.fw(816), 1\46029_7.fw(816) Version 1.3.1.0: ID: 277200 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277770 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\45996_3.fw(161), 1\46029_6.fw(800) Version 1.2.1.0: Firmware: 1\45996_1.fw(152), 1\45996_3.fw(153), 1\46029_6.fw(800) |