DWL@DWL10000433715
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.10.13.0 | * | 20/03/2024 | 4 Mo | EXE | AS4_HW_X20SC0842.exe | |
Description |
V4.0 HW Upgrade (X20SC0842) Revision information X20SC0842 Version 1.10.13.0: ID: 780185 Correction of the input filter with set "Filter off". Correction of the input filter, if a "Filter off" is set and a channel error is detected. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59385_1.fw(340) Version 1.10.12.0: ID: 710620 Timing of module internal communication updated The timing of the module internal communication was updated. Sporadic errors 98818, 119317, 99348, 102914, 99350 no longer occur. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 710785 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59385_1.fw(333) Version 1.10.11.1: ID: 692805 Improvement of the feedback diagnosis. Improvement of the feedback diagnosis of the output. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 692680 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 692580 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 7\59385_1.fw(332) Version 1.10.10.0: ID: 670215 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 668670 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59385_1.fw(331) Version 1.10.9.1: ID: 643135 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59385_1.fw(330) Version 1.10.9.0: ID: 618210 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59385_1.fw(330) Version 1.10.1.0: ID: 516610 / Support ID: 400203957 add PhysicalStateChannels on X20SLX842 add PhysicalStateChannels on X20SLX842. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 539150 Adapt filter algorithm to eliminate dependencies between TON and TOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 541650 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 549925 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 570155 Increase the tolerance of the voltage monitor The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59385_1.fw(325) Version 1.10.0.6: ID: 532880 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532885 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532890 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59385_1.fw(322) Version 1.10.0.3: ID: 473000 Improved stability The stability of the module was improved Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59385_1.fw(322) Version 1.10.0.2: ID: 473375 first official release first official release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59385_1.fw(320) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.10.12.0 | * | 16/04/2021 | 4 Mo | EXE | AS4_HW_X20SC0842.exe | |
Description |
V4.0 HW Upgrade (X20SC0842) Revision information X20SC0842 Version 1.10.12.0: ID: 710620 Timing of module internal communication updated The timing of the module internal communication was updated. Sporadic errors 98818, 119317, 99348, 102914, 99350 no longer occur. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 710785 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59385_1.fw(333) Version 1.10.11.1: ID: 692805 Improvement of the feedback diagnosis. Improvement of the feedback diagnosis of the output. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 692680 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 692580 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 7\59385_1.fw(332) Version 1.10.10.0: ID: 670215 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 668670 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59385_1.fw(331) Version 1.10.9.1: ID: 643135 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59385_1.fw(330) Version 1.10.9.0: ID: 618210 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59385_1.fw(330) Version 1.10.1.0: ID: 516610 / Support ID: 400203957 add PhysicalStateChannels on X20SLX842 add PhysicalStateChannels on X20SLX842. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 539150 Adapt filter algorithm to eliminate dependencies between TON and TOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 541650 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 549925 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 570155 Increase the tolerance of the voltage monitor The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59385_1.fw(325) Version 1.10.0.6: ID: 532880 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532885 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532890 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59385_1.fw(322) Version 1.10.0.3: ID: 473000 Improved stability The stability of the module was improved Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59385_1.fw(322) Version 1.10.0.2: ID: 473375 first official release first official release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59385_1.fw(320) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.10.11.1 | * | 10/12/2020 | 3 Mo | EXE | AS4_HW_X20SC0842.exe | |
Description |
V4.0 HW Upgrade (X20SC0842) Revision information X20SC0842 Version 1.10.11.1: ID: 692805 Improvement of the feedback diagnosis. Improvement of the feedback diagnosis of the output. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 692680 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 692580 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 7\59385_1.fw(332) Version 1.10.10.0: ID: 670215 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 668670 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59385_1.fw(331) Version 1.10.9.1: ID: 643135 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59385_1.fw(330) Version 1.10.9.0: ID: 618210 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59385_1.fw(330) Version 1.10.1.0: ID: 516610 / Support ID: 400203957 add PhysicalStateChannels on X20SLX842 add PhysicalStateChannels on X20SLX842. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 539150 Adapt filter algorithm to eliminate dependencies between TON and TOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 541650 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 549925 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 570155 Increase the tolerance of the voltage monitor The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59385_1.fw(325) Version 1.10.0.6: ID: 532880 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532885 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532890 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59385_1.fw(322) Version 1.10.0.3: ID: 473000 Improved stability The stability of the module was improved Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59385_1.fw(322) Version 1.10.0.2: ID: 473375 first official release first official release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59385_1.fw(320) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.10.9.2 | * | 31/01/2020 | 3 Mo | EXE | AS4_HW_X20SC0842.exe | |
Description |
V4.0 HW Upgrade (X20SC0842) Revision information X20SC0842 Version 1.10.9.2: ID: 670215 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59385_1.fw(330) Version 1.10.9.1: ID: 643135 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59385_1.fw(330) Version 1.10.9.0: ID: 618210 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59385_1.fw(330) Version 1.10.1.0: ID: 516610 / Support ID: 400203957 add PhysicalStateChannels on X20SLX842 add PhysicalStateChannels on X20SLX842. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 539150 Adapt filter algorithm to eliminate dependencies between TON and TOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 541650 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 549925 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 570155 Increase the tolerance of the voltage monitor The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59385_1.fw(325) Version 1.10.0.6: ID: 532880 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532885 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532890 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59385_1.fw(322) Version 1.10.0.3: ID: 473000 Improved stability The stability of the module was improved Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59385_1.fw(322) Version 1.10.0.2: ID: 473375 first official release first official release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59385_1.fw(320) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.10.9.1 | * | 16/05/2019 | 3 Mo | EXE | AS4_HW_X20SC0842.exe | |
Description |
V4.0 HW Upgrade (X20SC0842) Revision information X20SC0402 Version 1.10.9.1: ID: 643135 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59384_1.fw(330) Version 1.10.9.0: ID: 618210 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59384_1.fw(330) Version 1.10.1.0: ID: 516610 / Support ID: 400203957 add PhysicalStateChannels on X20SLX842 add PhysicalStateChannels on X20SLX842. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 539150 Adapt filter algorithm to eliminate dependencies between TON and TOF-filter Filter algorithm was adapted toeliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 541650 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 549925 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID:570155 Increase the tolerance of the voltage monitor The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59384_1.fw(325) Version 1.10.0.6: ID: 532880 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532885 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532890 Update ECAD data Update ECAD data Channel descriptionchanged: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59384_1.fw(322) Version 1.10.0.3: ID: 473000 Improved stability The stability of the module was improved Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59384_1.fw(322) Version 1.10.0.2: ID: 473375 first official release first official release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59384_1.fw(320) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.10.9.0 | * | 08/11/2018 | 3 Mo | EXE | AS4_HW_X20SC0842.exe | |
Description |
V4.0 HW Upgrade (X20SC0842) Revision information X20SC0402 Version 1.10.9.0: ID: 618210 logger entry 112174, 108078 Loggerentry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59384_1.fw(330) Version 1.10.1.0: ID: 516610 / Support ID: 400203957 add PhysicalStateChannels on X20SLX842 add PhysicalStateChannels on X20SLX842. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 539150 Adapt filter algorithm to eliminate dependencies between TON and TOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 541650 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 549925 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 570155 Increase the tolerance of the voltage monitor The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59384_1.fw(325) Version 1.10.0.6: ID: 532880 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532885 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532890 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59384_1.fw(322) Version 1.10.0.3: ID: 473000 Improved stability The stability of the module was improved Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\59384_1.fw(322) Version 1.10.0.2: ID: 473375 first official release first official release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59384_1.fw(320) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.10.1.0 | * | 05/03/2018 | 3 Mo | EXE | AS4_HW_X20SC0842.exe | |
Description |
V4.0 HW Upgrade (X20SC0842) Revision information X20SC0402 Version 1.10.1.0: ID: 516610 / Support ID: 400203957 add PhysicalStateChannels on X20SLX842 add PhysicalStateChannels on X20SLX842. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 539150 Adapt filter algorithm to eliminate dependencies between TON and TOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 541650 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 549925 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 570155 Increase the tolerance of the voltage monitor The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59226_1.fw(325) Version 1.10.0.6: ID: 532880 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532885 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532890 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59384_1.fw(322) Version 1.10.0.3: ID: 473000 Improved stability The stability of the module was improved Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59384_1.fw(322) Version 1.10.0.2: ID: 473375 firstofficial release first official release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59384_1.fw(320) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.10.0.6 | * | 04/10/2017 | 3 Mo | EXE | AS4_HW_X20SC0842.exe | |
Description |
V4.0 HW Upgrade (X20SC0842) Revision information X20SC0402 Version 1.10.0.6: ID: 532880 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532885 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532890 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmwarechanged: No Firmware: 1\59384_1.fw(322) Version 1.10.0.3: ID: 473000 Improved stability The stability of the module was improved Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59384_1.fw(322) Version 1.10.0.2: ID: 473375 first official release first official release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59384_1.fw(320) |