DWL@DWL10000433715

Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
1.10.13.0 * 20/03/2024 4 Mo EXE AS4_HW_X20SC0842.exe
Description V4.0 HW Upgrade (X20SC0842)

Revision information X20SC0842

Version 1.10.13.0:

ID: 780185
Correction of the input filter with set "Filter off".
Correction of the input filter, if a "Filter off" is set and a channel error is detected.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59385_1.fw(340)

Version 1.10.12.0:

ID: 710620
Timing of module internal communication updated
The timing of the module internal communication was updated. Sporadic errors 98818, 119317, 99348, 102914, 99350 no longer occur.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 710785
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring of module cycle time and slot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59385_1.fw(333)

Version 1.10.11.1:

ID: 692805
Improvement of the feedback diagnosis.
Improvement of the feedback diagnosis of the output.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 692680
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 692580 / Support ID: 400299371
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 7\59385_1.fw(332)

Version 1.10.10.0:

ID: 670215
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 668670
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59385_1.fw(331)

Version 1.10.9.1:

ID: 643135
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59385_1.fw(330)

Version 1.10.9.0:

ID: 618210
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59385_1.fw(330)

Version 1.10.1.0:

ID: 516610 / Support ID: 400203957
add PhysicalStateChannels on X20SLX842
add PhysicalStateChannels on X20SLX842.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 539150
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 541650
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 549925
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 570155
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59385_1.fw(325)

Version 1.10.0.6:

ID: 532880
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532885
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532890
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59385_1.fw(322)

Version 1.10.0.3:

ID: 473000
Improved stability
The stability of the module was improved
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59385_1.fw(322)

Version 1.10.0.2:

ID: 473375
first official release
first official release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59385_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
1.10.12.0 * 16/04/2021 4 Mo EXE AS4_HW_X20SC0842.exe
Description V4.0 HW Upgrade (X20SC0842)

Revision information X20SC0842

Version 1.10.12.0:

ID: 710620
Timing of module internal communication updated
The timing of the module internal communication was updated. Sporadic errors 98818, 119317, 99348, 102914, 99350 no longer occur.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 710785
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring of module cycle time and slot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59385_1.fw(333)

Version 1.10.11.1:

ID: 692805
Improvement of the feedback diagnosis.
Improvement of the feedback diagnosis of the output.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 692680
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 692580 / Support ID: 400299371
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 7\59385_1.fw(332)

Version 1.10.10.0:

ID: 670215
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 668670
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59385_1.fw(331)

Version 1.10.9.1:

ID: 643135
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59385_1.fw(330)

Version 1.10.9.0:

ID: 618210
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59385_1.fw(330)

Version 1.10.1.0:

ID: 516610 / Support ID: 400203957
add PhysicalStateChannels on X20SLX842
add PhysicalStateChannels on X20SLX842.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 539150
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 541650
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 549925
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 570155
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59385_1.fw(325)

Version 1.10.0.6:

ID: 532880
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532885
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532890
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59385_1.fw(322)

Version 1.10.0.3:

ID: 473000
Improved stability
The stability of the module was improved
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59385_1.fw(322)

Version 1.10.0.2:

ID: 473375
first official release
first official release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59385_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
1.10.11.1 * 10/12/2020 3 Mo EXE AS4_HW_X20SC0842.exe
Description V4.0 HW Upgrade (X20SC0842)

Revision information X20SC0842

Version 1.10.11.1:

ID: 692805
Improvement of the feedback diagnosis.
Improvement of the feedback diagnosis of the output.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 692680
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 692580 / Support ID: 400299371
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 7\59385_1.fw(332)

Version 1.10.10.0:

ID: 670215
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 668670
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59385_1.fw(331)

Version 1.10.9.1:

ID: 643135
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59385_1.fw(330)

Version 1.10.9.0:

ID: 618210
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59385_1.fw(330)

Version 1.10.1.0:

ID: 516610 / Support ID: 400203957
add PhysicalStateChannels on X20SLX842
add PhysicalStateChannels on X20SLX842.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 539150
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 541650
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 549925
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 570155
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59385_1.fw(325)

Version 1.10.0.6:

ID: 532880
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532885
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532890
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59385_1.fw(322)

Version 1.10.0.3:

ID: 473000
Improved stability
The stability of the module was improved
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59385_1.fw(322)

Version 1.10.0.2:

ID: 473375
first official release
first official release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59385_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
1.10.9.2 * 31/01/2020 3 Mo EXE AS4_HW_X20SC0842.exe
Description V4.0 HW Upgrade (X20SC0842)

Revision information X20SC0842

Version 1.10.9.2:

ID: 670215
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59385_1.fw(330)

Version 1.10.9.1:

ID: 643135
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59385_1.fw(330)

Version 1.10.9.0:

ID: 618210
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59385_1.fw(330)

Version 1.10.1.0:

ID: 516610 / Support ID: 400203957
add PhysicalStateChannels on X20SLX842
add PhysicalStateChannels on X20SLX842.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 539150
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 541650
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 549925
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 570155
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59385_1.fw(325)

Version 1.10.0.6:

ID: 532880
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532885
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532890
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59385_1.fw(322)

Version 1.10.0.3:

ID: 473000
Improved stability
The stability of the module was improved
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59385_1.fw(322)

Version 1.10.0.2:

ID: 473375
first official release
first official release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59385_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
1.10.9.1 * 16/05/2019 3 Mo EXE AS4_HW_X20SC0842.exe
Description V4.0 HW Upgrade (X20SC0842)

Revision information X20SC0402

Version 1.10.9.1:

ID: 643135
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59384_1.fw(330)

Version 1.10.9.0:

ID: 618210
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59384_1.fw(330)

Version 1.10.1.0:

ID: 516610 / Support ID: 400203957
add PhysicalStateChannels on X20SLX842
add PhysicalStateChannels on X20SLX842.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 539150
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted toeliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed:No
Firmware changed: Yes

ID: 541650
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 549925
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID:570155
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59384_1.fw(325)

Version 1.10.0.6:

ID: 532880
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532885
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532890
Update ECAD data
Update ECAD data
Channel descriptionchanged: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59384_1.fw(322)

Version 1.10.0.3:

ID: 473000
Improved stability
The stability of the module was improved
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59384_1.fw(322)

Version 1.10.0.2:

ID: 473375
first official release
first official release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59384_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
1.10.9.0 * 08/11/2018 3 Mo EXE AS4_HW_X20SC0842.exe
Description V4.0 HW Upgrade (X20SC0842)

Revision information X20SC0402

Version 1.10.9.0:

ID: 618210
logger entry 112174, 108078
Loggerentry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59384_1.fw(330)

Version 1.10.1.0:

ID: 516610 / Support ID: 400203957
add PhysicalStateChannels on X20SLX842
add PhysicalStateChannels on X20SLX842.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 539150
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 541650
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 549925
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 570155
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59384_1.fw(325)

Version 1.10.0.6:

ID: 532880
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532885
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532890
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59384_1.fw(322)

Version 1.10.0.3:

ID: 473000
Improved stability
The stability of the module was improved
Channel description changed: No
Configuration description changed: No
Firmwarechanged: Yes
Firmware: 1\59384_1.fw(322)

Version 1.10.0.2:

ID: 473375
first official release
first official release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59384_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
1.10.1.0 * 05/03/2018 3 Mo EXE AS4_HW_X20SC0842.exe
Description V4.0 HW Upgrade (X20SC0842)

Revision information X20SC0402

Version 1.10.1.0:

ID: 516610 / Support ID: 400203957
add PhysicalStateChannels on X20SLX842
add PhysicalStateChannels on X20SLX842.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 539150
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 541650
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 549925
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 570155
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59226_1.fw(325)

Version 1.10.0.6:

ID: 532880
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532885
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532890
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59384_1.fw(322)

Version 1.10.0.3:

ID: 473000
Improved stability
The stability of the module was improved
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59384_1.fw(322)

Version 1.10.0.2:

ID: 473375
firstofficial release
first official release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59384_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
1.10.0.6 * 04/10/2017 3 Mo EXE AS4_HW_X20SC0842.exe
Description V4.0 HW Upgrade (X20SC0842)

Revision information X20SC0402

Version 1.10.0.6:

ID: 532880
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532885
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532890
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: Yes
Firmwarechanged: No
Firmware: 1\59384_1.fw(322)

Version 1.10.0.3:

ID: 473000
Improved stability
The stability of the module was improved
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59384_1.fw(322)

Version 1.10.0.2:

ID: 473375
first official release
first official release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59384_1.fw(320)
Loading