DWL@DWL10000240313
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.2.0.0 | * | 23/07/2021 | 2 MB | EXE | AS4_HW_X20CP3484.exe | |
Description |
V4.0 HW Upgrade (X20CP3484) Revision information X20CP3484 Version 1.2.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.5.0: ID: 429055 SupportBonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 429160 / Support ID: 400151182 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\9126a0.pci(18), 1\9126_0.pci(7), 1\9126b0.epl(66) Version 1.1.4.0: ID: 359010 POWERLINK MN mode: If "Multiplexing prescale" >= 9, then the input data of the multiplexed stations that were configured in the last "network cycle" were not transferred in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 359245 / Support ID: 400113446 POWERLINK V2 MN mode: Asynchronous connection losses may occur as a result of high asynchronous loads on the POWERLINK network and high loads on the CPU. This could maintain you to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Version 1.1.3.0: ID: 332375 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337515 / Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9126a0.pci(18), 1\9126_0.pci(7), 1\9126b0.epl(63) Version 1.1.2.0: ID: 296125 Compatibility to Atom CPU Allows the replacement ofa X20CPx48x through X20CPx58x in an existing AS configuration. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9126a0.pci(18), 1\9126_0.pci(7), 1\9126b0.epl(60) Version 1.1.1.0: ID: 285875 POWERLINK V2 CN mode: Asynchronous packets lost when there is a large asynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 286105 POWERLINK V2: Large fluctuations of IEEE 1588 Nettime (used for safety logbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9126a0.pci(18), 1\9126_0.pci(7), 1\9126b0.epl(60) Version 1.1.0.2: ID: 256750 / Support ID: 400057319 POWERLINK: In controlled node mode, the I/O mapping was not applied when the manager was restarted. Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 256880 POWERLINK: LinkOK data point added. Channeldescription changed: Yes Configuration description changed: No Firmware changed: No ID: 257030 POWERLINK: Support for 100 Mbit fullduplex in Ethernet operating mode. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID:260890 POWERLINK: L/A LED only shows Link and not Activity -> corrected. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265740 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265840 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with "Chaned Station" on the same network Error correction: When an iCN is used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning isthat the sync response frames that are used to measure the timing of the "Chained Station" are not recognized by the iCN. Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\9126a0.pci(18), 1\9126_0.pci(7), 1\9126b0.epl(58) Version 1.0.15.0: ID: 230800 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9126a0.pci(16), 1\9126_0.pci(7), 1\9126b0.epl(52) Version 1.0.14.0: ID: 220510 POWERLINK V2: Boot behavior improved Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9126a0.pci(16), 1\9126_0.pci(6), 1\9126b0.epl(51) Version 1.0.13.0: ID: 213055 CN mode: Various error corrections made. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9126a0.pci(16), 1\9126_0.pci(6), 1\9126b0.epl(47) Version 1.0.12.0: ID: 200955 / Support ID: 400020310 New POWERLINK firmware V45 and basis firmware V16 POWERLINK V2 CN mode: - Frequent MN failures result in CPU going into Service mode. - The PollResponse data from multiplexed stations are now updated in every POWERLINK cycle. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9126a0.pci(16), 1\9126_0.pci(6), 1\9126b0.epl(45) Version 1.0.11.0: ID: 199565 New POWERLINK V1/V2 firmware V44 CN mode: Various error corrections made. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9126a0.pci(15), 1\9126_0.pci(6), 1\9126b0.epl(44) Version 1.0.10.1: ID: 191795 New POWERLINK V1/V2 Firmware V42 and base firmware V15 - Error correction for POWERLINK V2: After network disturbances, failed stations were left out of cyclic traffic. - Error correction POWERLINK V2 CN mode: Failure of a SoC resulted immediately in incorrect failure detection by manager. - Error correction: Configuring too small values for PollResponse timeouts caused manager to fail. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9126a0.pci(15), 1\9126_0.pci(6), 1\9126b0.epl(42) Version 1.0.8.0: ID: 182100 New POWERLINK V1/V2 firmware V38 - Error correction for POWERLINK V2: Parameter "CycleIdleTime" was not calculated correctly. - Error correction: ModbusTCP on POWERLINK interfaces was not working. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9126a0.pci(14), 1\9126_0.pci(6), 1\9126b0.epl(38) Version 1.0.7.0: ID: 178055 New POWERLINK V1/V2 firmware V37 Error corrections: - POWERLINK V2 CN mode: Various error corrections made. - POWERLILNK V2: Asynchronous frames can now bereceived with the Powerlink library starting with channel >= 0x20 (previouslystarting with 0xA0). Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9126a0.pci(14), 1\9126_0.pci(6), 1\9126b0.epl(37) Version 1.0.6.0: ID: 171835 New Base Firmware V14 and POWERLINK Firmware V36 Error correction: - When using an I/O prescaler > 1, in certain circumstances the old input data for the station is provided to the application. - With the option 'Fast reaction' and multiplexed station the POWERLINK manager fails when there is a disturbance on the network. Changes with POWERLINK V2: - The poll response from the manager is now sent at the beginning of the POWERLINK cycle. - Stations are now addressed with poll requests starting inPreOperational 2status. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9126a0.pci(14), 1\9126_0.pci(6), 1\9126b0.epl(36) Version 1.0.5.0: ID: 165840 New POWERLINK V1/V2 Firmware V34 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9126a0.pci(13), 1\9126_0.pci(6), 1\9126b0.epl(34) Version1.0.4.0: ID: 165480 New POWERLINK V1/V2 Firmware V33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9126a0.pci(13), 1\9126_0.pci(6), 1\9126b0.epl(33) Version 1.0.3.0: ID: 164795 New POWERLINK V1/V2 Firmware V31 - Optimizations for EPL V2 startup carried out. - NettimeIEEE 1588 for EPL V2 implemented. - From now on, the asynchronous scheduler will handle asynchronous requestsbased on their priority. Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 1\9126a0.pci(13), 1\9126_0.pci(6), 1\9126b0.epl(31) Version 1.0.2.0: ID: 163820 New Base Firmware V13 Error correction: problems when booting Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9126a0.pci(13), 1\9126_0.pci(6), 1\9126b0.epl(30) Version 1.0.1.0: ID: 160785 New POWERLINK V1/V2 Firmware V30 In "Controlled Node" mode, the following errors may occur: - With heavy asynchronous loads, asynchronous TX packets may be lost. - Collisions on the network can cause the station to stop receiving Ethernet packets. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9126a0.pci(12), 1\9126_0.pci(6), 1\9126b0.epl(30) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.1.5.0 | * | 15/06/2015 | 2 MB | EXE | AS4_HW_X20CP3484.exe | |
Description |
V4.0 HW Upgrade (X20CP3484) Revision information X20CP3484 Version 1.1.5.0: ID: 429055 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 429160 / Support ID: 400151182 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9126a0.pci(18), 1\9126_0.pci(7), 1\9126b0.epl(66) Version 1.1.3.0: ID: 332375 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communicationoff" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337515 / Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 1\9126a0.pci(18), 1\9126_0.pci(7), 1\9126b0.epl(63) Version 1.1.2.0: ID: 296125 Compatibility to Atom CPU Allows the replacement of a X20CPx48x through X20CPx58x in an existing AS configuration. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9126a0.pci(18), 1\9126_0.pci(7), 1\9126b0.epl(60) Version 1.1.1.0: ID: 285875 POWERLINK V2 CN mode: Asynchronous packets lostwhen there is a large asynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 286105 POWERLINK V2: Large fluctuations of IEEE 1588 Nettime (used for safety logbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9126a0.pci(18), 1\9126_0.pci(7), 1\9126b0.epl(60) Version 1.1.0.2: ID: 256750 / Support ID: 400057319 POWERLINK: In controlled node mode, the I/O mapping was not applied when the manager was restarted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 256880 POWERLINK: LinkOK data point added. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 257030 POWERLINK: Support for 100 Mbit full duplex in Ethernet operating mode. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 260890 POWERLINK: L/A LED only shows Link and not Activity -> corrected. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265740 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:265840 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with "Chaned Station" on the same network Error correction: When an iCN is used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning is that the sync response frames that are used to measure the timing of the "Chained Station" are not recognized by the iCN. Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 1\9126a0.pci(18), 1\9126_0.pci(7), 1\9126b0.epl(58) Version 1.0.15.0: ID:230800 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9126a0.pci(16), 1\9126_0.pci(7), 1\9126b0.epl(52) Version 1.0.14.0: ID: 220510 POWERLINK V2: Boot behavior improved Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\9126a0.pci(16), 1\9126_0.pci(6), 1\9126b0.epl(51) Version 1.0.13.0: ID: 213055 CN mode: Various error corrections made. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9126a0.pci(16), 1\9126_0.pci(6), 1\9126b0.epl(47) Version 1.0.12.0: ID: 200955 / Support ID: 400020310 New POWERLINK firmware V45 and basis firmware V16 POWERLINK V2 CN mode: - Frequent MN failures result in CPU going into Service mode. - The PollResponse data from multiplexed stations are now updated in every POWERLINK cycle. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9126a0.pci(16), 1\9126_0.pci(6), 1\9126b0.epl(45) Version 1.0.11.0: ID: 199565 New POWERLINK V1/V2 firmware V44 CN mode: Various error corrections made. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9126a0.pci(15), 1\9126_0.pci(6), 1\9126b0.epl(44) Version 1.0.10.1: ID: 191795 New POWERLINK V1/V2 Firmware V42 and base firmware V15 - Error correctionfor POWERLINK V2: After network disturbances, failed stations were left out of cyclic traffic. - Error correction POWERLINK V2 CN mode: Failure of a SoC resulted immediately in incorrect failure detection by manager. - Error correction: Configuring too small values for PollResponse timeouts caused manager to fail. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9126a0.pci(15), 1\9126_0.pci(6), 1\9126b0.epl(42) Version 1.0.8.0: ID: 182100 New POWERLINK V1/V2 firmware V38 - Error correction for POWERLINK V2: Parameter "CycleIdleTime" was not calculated correctly. - Error correction: ModbusTCP on POWERLINK interfaces was not working. Channel descriptionchanged: No Configuration description changed: No Firmware changed:No Firmware: 1\9126a0.pci(14), 1\9126_0.pci(6), 1\9126b0.epl(38) Version 1.0.7.0: ID: 178055 New POWERLINK V1/V2 firmware V37 Error corrections: - POWERLINK V2 CN mode: Various error corrections made. - POWERLILNK V2: Asynchronous frames can now be received with the Powerlinklibrary starting with channel >= 0x20 (previously starting with 0xA0). Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9126a0.pci(14), 1\9126_0.pci(6), 1\9126b0.epl(37) Version 1.0.6.0: ID: 171835 New Base Firmware V14 and POWERLINK Firmware V36 Error correction: - When using an I/O prescaler > 1, in certain circumstances the old input data for the station is provided to the application. - With the option 'Fast reaction' andmultiplexed station the POWERLINK manager fails when there is a disturbance on the network. Changes with POWERLINK V2: - The poll response from the manager is now sent at the beginning of the POWERLINK cycle. - Stations are now addressed with poll requests starting in PreOperational 2 status. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9126a0.pci(14), 1\9126_0.pci(6), 1\9126b0.epl(36) Version 1.0.5.0: ID: 165840 New POWERLINK V1/V2 Firmware V34 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9126a0.pci(13), 1\9126_0.pci(6), 1\9126b0.epl(34) Version 1.0.4.0: ID:165480 New POWERLINK V1/V2 Firmware V33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9126a0.pci(13), 1\9126_0.pci(6), 1\9126b0.epl(33) Version 1.0.3.0: ID: 164795 New POWERLINK V1/V2 Firmware V31 - Optimizations for EPL V2 startup carried out. - Nettime IEEE 1588 for EPL V2 implemented. - From now on, the asynchronous scheduler will handle asynchronous requestsbased on their priority. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9126a0.pci(13), 1\9126_0.pci(6), 1\9126b0.epl(31) Version 1.0.2.0: ID: 163820 New Base Firmware V13 Error correction: problems when booting Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9126a0.pci(13),1\9126_0.pci(6), 1\9126b0.epl(30) Version 1.0.1.0: ID: 160785 New POWERLINK V1/V2 Firmware V30 In "Controlled Node" mode, the following errors may occur: - With heavy asynchronous loads, asynchronous TXpackets may be lost. - Collisions on the network can cause the station to stop receiving Ethernet packets. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9126a0.pci(12), 1\9126_0.pci(6), 1\9126b0.epl(30) |