DWL@DWL10000389072
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.3.1.0 | * | 24/05/2022 | 1,002 Ko | EXE | AS4_HW_X20AO4632.exe | |
Description |
V4.0 HW Upgrade (X20AO4632) Revision information X20AO4632 Version 1.3.1.0: ID: 751040 Support new HW variant 30 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7077_2.fw(1), 1\7077_3.fw(3), 1\7077_30.fw(110) Version 1.2.0.0: ID: Adaptations for Automation Studio4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.2.0: ID: 522490 Module documentation revised Data sheet V3.11 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 1\7077_2.fw(1), 1\7077_3.fw(3) Version 1.0.1.0: ID: 323825 Enhancement online-help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7077_2.fw(1), 1\7077_3.fw(3) Version 1.0.0.2: ID: 195930 Correction version limitation SGC Correction version limitation SGC Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7077_2.fw(1), 1\7077_3.fw(3) Version 1.0.0.1: ID: 195250 Correction datapoint channels for Fieldbusdesigner Correction datapoint channels for Fieldbusdesigner Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7077_2.fw(1), 1\7077_3.fw(3) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.2.0.0 | * | 23/07/2021 | 945 Ko | EXE | AS4_HW_X20AO4632.exe | |
Description |
V4.0 HW Upgrade (X20AO4632) Revision information X20AO4632 Version 1.2.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.2.0: ID: 522490 Module documentation revised Data sheet V3.11 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7077_2.fw(1), 1\7077_3.fw(3) Version 1.0.1.0: ID: 323825 Enhancement online-help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7077_2.fw(1), 1\7077_3.fw(3) Version1.0.0.2: ID: 195930 Correction version limitation SGC Correction version limitation SGC Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7077_2.fw(1), 1\7077_3.fw(3) Version 1.0.0.1: ID: 195250 Correction datapoint channels for Fieldbusdesigner Correction datapoint channels for Fieldbusdesigner Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7077_2.fw(1), 1\7077_3.fw(3) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.1.0.0 | * | 25/10/2019 | 942 Ko | EXE | AS4_HW_X20AO4632.exe | |
Description |
V4.0 HW Upgrade (X20AO4632) Revision information X20AO4632 Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.2.0: ID: 522490 Module documentation revised Data sheet V3.11 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7077_2.fw(1), 1\7077_3.fw(3) Version 1.0.1.0: ID: 323825 Enhancement online-help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7077_2.fw(1), 1\7077_3.fw(3) Version 1.0.0.2: ID: 195930 Correction version limitation SGC Correction version limitation SGC Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7077_2.fw(1), 1\7077_3.fw(3) Version 1.0.0.1: ID: 195250 Correction datapoint channels for Fieldbusdesigner Correction datapoint channels for Fieldbusdesigner Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7077_2.fw(1), 1\7077_3.fw(3) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.0.2.0 | * | 06/03/2017 | 887 Ko | EXE | AS4_HW_X20AO4632.exe | |
Description |
V4.0 HW Upgrade (X20AO4632) Revision information X20AO4632 Version 1.0.2.0: ID: 522490 Module documentation revised Data sheet V3.11 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 1\7077_2.fw(1), 1\7077_3.fw(3) Version 1.0.1.0: ID: 323825 Enhancement online-help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7077_2.fw(1), 1\7077_3.fw(3) Version 1.0.0.2: ID: 195930 Correction version limitation SGC Correction version limitation SGC Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7077_2.fw(1), 1\7077_3.fw(3) Version 1.0.0.1: ID: 195250 Correction datapoint channels for Fieldbusdesigner Correction datapoint channels for Fieldbusdesigner Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7077_2.fw(1), 1\7077_3.fw(3) |