DWL@DWL10000260272

Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.3.0.1 * 09/09/2020 290 Ko EXE AS4_HW_8BVI0110HWD0.000-1.exe
Description V4.0 HW Upgrade (8BVI0110HWD0.000-1)

Revision information 8BVI0014HCD0.000-1

Version 2.3.0.1:

ID: 682245
Parameter "SdcEnabled"initialized incorrectly
Data type of parameter was changed to STRING andinital value to "off".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 682440
Add-on for usage of automatic DNA configuration
Feature add-on "DNA Configuration automatic" from Automation Studio 4.9
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.3.0.0:

ID: 600390
Misconfiguration of mapp Motion axis assignment not detected in Automation Studio
mapp Motion axes can be assigned to a drive multiple times. This error is not recognized until runtime.
Corrected in combination with:
- mapp Motion V5.4.0
- Automation Studio V4.4.4
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 2.2.0.0:

ID: 549240
Support of motion system mapp Motion
HWX file extended forusage with motion system mapp Motion.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 1.0.0.2:

ID: 336130
HW upgrade for support of DNA from revivision N0
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.3.0.0 * 18/09/2018 246 Ko EXE AS4_HW_8BVI0110HWD0.000-1.exe
Description V4.0 HW Upgrade (8BVI0110HWD0.000-1)

Revision information 8BVI0014HCD0.000-1

Version 2.3.0.0:

ID: 600390
Misconfiguration of mapp Motion axis assignment not detected in Automation Studio
mapp Motion axes can be assigned to a drive multiple times. This error is not recognized until runtime.
Corrected in combination with:
- mapp Motion V5.4.0
- Automation Studio V4.4.4
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 2.2.0.0:

ID: 549240
Support of motion system mapp Motion
HWX file extended for usage with motion system mapp Motion.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 1.0.0.2:

ID: 336130
HW upgrade for support of DNA from revivision N0
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.2.0.0 * 01/09/2017 236 Ko EXE AS4_HW_8BVI0110HWD0.000-1.exe
Description V4.0 HW Upgrade (8BVI0110HWD0.000-1)

Revision information 8BVI0014HCD0.000-1

Version 2.2.0.0:

ID: 549240
Support of motion system mapp Motion
HWX file extended for usage with motion system mapp Motion.
Channel description changed: No
Configuration description changed:No
Firmware changed: No

Version 1.0.0.2:

ID: 336130
HW upgrade for support of DNA from revivision N0
Channel description changed: No
Configuration description changed: No
Firmware changed: No