DWL@DWL10000315594

Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.2.2.0 * 26/07/2021 297 KB EXE AS4_HW_5PP5IO.GNAC-00.exe
Description V4.0 HW Upgrade (5PP5IO.GNAC-00)

Revision information 5PP5IO.GNAC-00.GNAC-00

Version 2.2.2.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration descriptionchanged: yes
Firmware changed: no

Version 2.1.2.0:

ID: 425150
5PP5IO.GNAC-00 can be used in terminal configuration
Mandatoryversions:
- Automation Studio 4.1.6.x
- V2.0.5.0 von 5PC511.SX01-00
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\46301_0.fp(10)

Version 2.1.1.0:

ID: 401860
Corrections for 5PP5IO.GNAC-00
- The I/O mapping of module is now available in ARwin too.
- It is not longer necessary to disable the module to compile ARwin correctly.
- To eliminate warning entries in logger it is mandatory to use latest available hardware upgrades of modules 5PC511.SX01-00 or 5PP520.0573-01 and 5PP5IO.GNAC-00.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\46301_0.fp(10)

Version 2.1.0.0:

ID: 340520
New firmware version V00.10 and APROL support for AS4.x added
- LED for terminating resistor inverted,
Channel description changed:No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\46301_0.fp(10)

Version 2.0.1.1:

ID: 340520
New firmware version V00.10 and APROL support for AS4.x added
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\46301_0.fp(10)

Version 2.0.1.0:

ID: 279645
Support for 5PP5IO.GNAC-00
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\46301_0.fp(8)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.1.2.0 * 03/04/2015 314 KB EXE AS4_HW_5PP5IO.GNAC-00.exe
Description V4.0 HW Upgrade (5PP5IO.GNAC-00)

Revision information 5PP5IO.GNAC-00

Version 2.1.2.0:

ID: 425150
5PP5IO.GNAC-00 can be used in terminal configuration
Mandatory versions:
- Automation Studio 4.1.6.x
- V2.0.5.0 von 5PC511.SX01-00
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\46301_0.fp(10)

Version 2.1.1.0:

ID: 401860
Corrections for 5PP5IO.GNAC-00
- The I/O mapping of module is now available in ARwin too.
- It is not longer necessary to disable the module to compile ARwin correctly.
- To eliminate warning entries in logger it is mandatory to use latest available hardware upgrades of modules 5PC511.SX01-00 or 5PP520.0573-01 and 5PP5IO.GNAC-00.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\46301_0.fp(10)

Version 2.1.0.0:

ID: 340520
New firmware version V00.10 and APROL support for AS4.x added
- LED for terminating resistor inverted,
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\46301_0.fp(10)

Version 2.0.1.1:

ID: 340520
New firmware version V00.10 and APROL support for AS4.x added
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\46301_0.fp(10)

Version 2.0.1.0:

ID: 279645
Support for 5PP5IO.GNAC-00
Channel description changed: Yes
Configuration description changed:Yes
Firmware changed: Yes
Firmware: 1\46301_0.fp(8)
Loading
Retour à la liste

Veuillez sélectionner un pays et une langue

B&R Logo