DWL@DWL10000310347
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.8.0.0 | * | 18/04/2024 | 3 Mo | EXE | AS4_HW_5LS187.6-1.exe | |
Description |
V4.0 HW Upgrade (5LS187.6-1) Revision information 5LS187.6-1 Version 1.8.0.0: ID: 782940 / Support ID: 400413350 Fix bug in hardware revision emulation Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(18195), 1\7669_1.pci(18184), 1\7669_2.pci(18184), 1\7669b0.can(130), 1\7669b1.can(0), 1\7669b2.can(0), 1\7669b0.epl(71), 1\7669b1.epl(71), 1\7669b2.epl(71) Version 1.7.0.0: ID: 771965 Support HW variant 2 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(18195), 1\7669_1.pci(18182), 1\7669_2.pci(18183), 1\7669b0.can(130), 1\7669b1.can(0), 1\7669b2.can(0), 1\7669b0.epl(71), 1\7669b1.epl(71), 1\7669b2.epl(71) Version 1.6.0.0: ID: 735735 Update problem If the firmware update of the interface card was interrupted (e.g. by a power failure), it was possible that theinterface was no longer booted by Automation Runtime. This problem can only occur with interfaces with revisions smaller than H0 and when the hardware upgrade is changed. To correct this problem, it is necessary to switch to another hardware upgrade. This will force an update or use this current hardwareupgrade. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 770535 Resolve potential loss of remanent data Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(18195), 1\7669_1.pci(18182), 1\7669b0.can(130), 1\7669b1.can(0), 1\7669b0.epl(71), 1\7669b1.epl(71) Version 1.5.0.0: ID: 730435 Support HW variant 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(17938), 1\7669_1.pci(17923), 1\7669b0.can(130), 1\7669b1.can(0), 1\7669b0.epl(70), 1\7669b1.epl(70) Version 1.4.1.0: ID: 699115 Support for automatic DNA configuration from AS 4.9.1 Channel description changed:No Configuration description changed: Yes Firmware changed: No ID: 699220 Module documentation revised Data sheet V 1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(17682), 1\7669b0.can(130), 1\7669b0.epl(69) Version 1.4.0.0: ID: 686305 Corrected handling of RTR objects Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(17682), 1\7669b0.can(130), 1\7669b0.epl(69) Version 1.3.0.0: ID: 442030 / Support ID: 0 POWERLINK V2 operating mode: managing node An error is causing higher transfer times on the PCI bus that are resultingin POWERLINK and I/O cycle time violations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(17170), 1\7669b0.can(122), 1\7669b0.epl(67) Version 1.2.7.0: ID: 429220 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 429240 / Support ID: 400151182 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16914), 1\7669b0.can(122), 1\7669b0.epl(66) Version 1.2.6.0: ID: 391580 Possibly incorrect display of the Powerlink status LEDs Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16402), 1\7669b0.can(122), 1\7669b0.epl(64) Version 1.2.5.0: ID: 376441 / Support ID: 400120997 Module sporadically not recognized in APC910 when booting Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16401), 1\7669b0.can(122), 1\7669b0.epl(64) Version 1.2.4.0: ID: 358935 POWERLINK MN mode: If "Multiplexing prescale" >= 9, then the input data of the multiplexed stations that were configured in the last "network cycle" were not transferred incertain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 359160 / Support ID: 400113446 POWERLINK V2 MN mode: Asynchronous connection losses may occur as a result of high asynchronous loads on the POWERLINK networkand high loads on the CPU. This could maintain you to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.2.3.0: ID: 332305 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 336710 POWERLINK V2 MN mode: It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337445/ Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16143), 1\7669b0.can(122), 1\7669b0.epl(63) Version 1.2.2.0: ID: 294795 / Support ID: 400070288 Update problem by plc restart Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(15375), 1\7669b0.can(122), 1\7669b0.epl(60) Version 1.2.1.0: ID: 285945 POWERLINK V2 CN mode: Asynchronous packets lost when there is a large asynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 286025 POWERLINK V2: Largefluctuations of IEEE 1588 Nettime (used for safety logbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(15374), 1\7669b0.can(122), 1\7669b0.epl(60) Version 1.2.0.2: ID: 256805 / Support ID: 400057319 POWERLINK: In controlled node mode, the I/O mapping was not applied when the manager was restarted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 256915 POWERLINK: LinkOK data point added. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 256960 POWERLINK: The net time is not always transferred correctly to the application. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:257050 POWERLINK: Support for 100 Mbit full duplex in Ethernet operatingmode. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 265695 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 265900 POWERLINK V2: If the the Ready-Flag was canceled on the network, the ModuleOK was not cleared. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265795 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with "Chaned Station" on the same network Error correction: When an iCN is used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning isthat the sync response frames that are used to measure the timing of the "Chained Station" are not recognized by the iCN. Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(14861), 1\7669b0.can(122), 1\7669b0.epl(58) Version 1.1.13.0: ID: 226710 / Support ID: 400041497 Problems starting CAN-FW corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13324), 1\7669b0.can(122), 1\7669b0.epl(52) Version 1.1.12.0: ID: 230840 POWERLINK V2 CN mode: Frequent MN failures result in CPU goinginto Service mode. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13323), 1\7669b0.can(122), 1\7669b0.epl(52) Version 1.1.11.0: ID: 229065 CAN transmitter blockade after cable un-/plugged corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13067), 1\7669b0.can(122), 1\7669b0.epl(51) Version 1.1.10.0: ID: 224445 CAN TransmitQueue Reset command corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13067), 1\7669b0.can(120), 1\7669b0.epl(51) Version 1.1.9.0: ID: 220435 POWERLINK V2: Boot behavior improved Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13067), 1\7669b0.can(117), 1\7669b0.epl(51) Version 1.1.8.0: ID: 213030 CN mode: Various error corrections made. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(12043), 1\7669b0.can(117), 1\7669b0.epl(47) Version 1.1.7.0: ID: 206910 New POWERLINK firmware V45 and basis firmware V11 POWERLINK V2 CN mode: - Frequent MN failures result in CPU going into Service mode. - The PollResponse data from multiplexed stations are now updated in every POWERLINK cycle. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(11531), 1\7669b0.can(117), 1\7669b0.epl(45) Version 1.1.6.0: ID: 199525 New POWERLINK V1/V2 firmware V44 CN mode: Various error corrections made. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(11274), 1\7669b0.can(117), 1\7669b0.epl(44) Version 1.1.5.1: ID: 191750 New POWERLINK V1/V2 Firmware V42 and basis firmware V10 - Error correction for POWERLINK V2: After network disturbances, failed stations were left out of cyclic traffic. - Error correction POWERLINK V2 CN mode: Failure of a SoC resulted immediately in incorrect failure detection by manager. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(10762), 1\7669b0.can(117), 1\7669b0.epl(42) Version 1.1.4.0: ID: 185600 New POWERLINK V1/V2 firmware V39 and basis firmware V9 - Error correction for POWERLINK V2: Certain configurations may cause multiplexed stations to fail. - Error correction for POWERLINK V2: An error while switching the alternating buffer caused old input data to be resent. (This error only occurred with upgrade 1.1.3.0.) - Error correction: In configurations with a large amount of I/O data, incorrect input data was sent. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9993), 1\7669b0.can(117), 1\7669b0.epl(39) Version 1.1.3.0: ID: 183640 New POWERLINK V1/V2 firmware V38 and basis firmware V8 - Error correction for POWERLINK V2: Parameter "CycleIdleTime" was not calculated correctly. - Error correction: ModbusTCP on POWERLINK interfaces was not working. - Improved stability for network disturbances. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9736), 1\7669b0.can(117), 1\7669b0.epl(38) Version 1.1.2.0: ID: 178025 New POWERLINK V1/V2 firmware V37 and base firmware V6 Error corrections: - POWERLINK V2 CN mode: Various error corrections made. - Asynchronous scheduler: The host has only sent an asynchronous frame in max. every secondcycle. - POWERLILNK V2: Asynchronous frames can now be received with thePowerlink library starting with channel >= 0x20 (previously starting with 0xA0). Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9478), 1\7669b0.can(117), 1\7669b0.epl(37) Version 1.1.1.0: ID: 173335 New POWERLINK firmware V36 Error correction: - When using an I/O prescaler > 1, in certain circumstances the old input data for the station is provided to the application. - ISSI-RAMs are supported. Changes - POWERLINK V2: - The poll response from the manager is now sent at the beginning of the POWERLINK cycle. - From now on, stations are addressed with poll requests starting in status"PreOperational 2". Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9221), 1\7669b0.can(117), 1\7669b0.epl(36) Version 1.1.0.0: ID: 171125 Performance improvement - POWERLINKmanager Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8964), 1\7669b0.can(117), 1\7669b0.epl(35) Version 1.0.6.0: ID: 167027 5LS187.6-1 doesn't works with Automation Runtime >= 2.92 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 167200 New base firmware V3 Collisions resultedin transmission of invalid frames. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware:1\7669_0.pci(8707), 1\7669b0.can(117), 1\7669b0.epl(34) Version 1.0.5.0: ID: 165815 New POWERLINK V1/V2 Firmware V34 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8706), 1\7669b0.can(117), 1\7669b0.epl(34) Version 1.0.4.0: ID: 165455 New POWERLINK V1/V2 Firmware V33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8450), 1\7669b0.epl(33) Version 1.0.3.0: ID: 164770 New POWERLINK V1/V2Firmware V31 - Optimizations for EPL V2 startup carried out. - Nettime IEEE 1588 for EPL V2 implemented. - From now on, the asynchronous scheduler will handle asynchronous requestsbased on their priority. Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(7938), 1\7669b0.epl(31) Version 1.0.1.0: ID: 160755 New Firmware V30 In "Controlled Node" mode, the following errors may occur: - With heavy asynchronous loads, asynchronous TX packets may be lost. - Collisions on the network can cause the station to stop receiving Ethernet packets. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(7682), 1\7669b0.epl(30) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.7.0.0 | * | 23/06/2023 | 3 Mo | EXE | AS4_HW_5LS187.6-1.exe | |
Description |
V4.0 HW Upgrade (5LS187.6-1) Revision information 5LS187.6-1 Version 1.7.0.0: ID: 771965 Support HW variant 2 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(18195), 1\7669_1.pci(18182), 1\7669_2.pci(18183), 1\7669b0.can(130), 1\7669b1.can(0), 1\7669b2.can(0), 1\7669b0.epl(71), 1\7669b1.epl(71), 1\7669b2.epl(71) Version 1.6.0.0: ID: 735735 Update problem If the firmware update of the interface card was interrupted (e.g. by a power failure), it was possible that the interface was no longer booted by Automation Runtime. This problem can only occur with interfaces with revisions smaller than H0 and when the hardware upgrade is changed. To correct this problem, it is necessary to switch to another hardware upgrade. This will force an update or use this current hardware upgrade. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 770535 Resolve potential loss of remanent data Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(18195), 1\7669_1.pci(18182), 1\7669b0.can(130), 1\7669b1.can(0), 1\7669b0.epl(71), 1\7669b1.epl(71) Version 1.5.0.0: ID: 730435 Support HW variant 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(17938), 1\7669_1.pci(17923), 1\7669b0.can(130), 1\7669b1.can(0), 1\7669b0.epl(70), 1\7669b1.epl(70) Version 1.4.1.0: ID: 699115 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 699220 Module documentation revised Data sheet V 1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(17682), 1\7669b0.can(130), 1\7669b0.epl(69) Version 1.4.0.0: ID: 686305 Corrected handling of RTRobjects Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(17682), 1\7669b0.can(130), 1\7669b0.epl(69) Version 1.3.0.0: ID: 442030 / Support ID: 0 POWERLINK V2 operating mode: managing node An error iscausing higher transfer times on the PCI bus that are resulting in POWERLINK and I/O cycle time violations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(17170), 1\7669b0.can(122), 1\7669b0.epl(67) Version 1.2.7.0: ID: 429220 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 429240 / Support ID: 400151182 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16914), 1\7669b0.can(122), 1\7669b0.epl(66) Version 1.2.6.0: ID: 391580 Possibly incorrect display of the Powerlink status LEDs Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16402), 1\7669b0.can(122), 1\7669b0.epl(64) Version 1.2.5.0: ID: 376441 / Support ID: 400120997 Module sporadically not recognized in APC910 when booting Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16401), 1\7669b0.can(122), 1\7669b0.epl(64) Version 1.2.4.0: ID: 358935 POWERLINK MN mode: If "Multiplexing prescale" >= 9, then the input data of the multiplexed stations that were configured in the last "network cycle" were not transferred in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 359160 / Support ID: 400113446 POWERLINK V2 MN mode: Asynchronous connection losses may occur as a result of high asynchronous loads on the POWERLINK network and high loads on the CPU. This could maintain you to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.2.3.0: ID: 332305 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration maycause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem.It is also possible to set "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 336710 POWERLINK V2 MN mode: It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337445 / Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16143), 1\7669b0.can(122), 1\7669b0.epl(63) Version 1.2.2.0: ID: 294795 / Support ID: 400070288 Update problem by plc restart Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(15375), 1\7669b0.can(122), 1\7669b0.epl(60) Version 1.2.1.0: ID: 285945 POWERLINK V2 CN mode: Asynchronous packets lost when there is a large asynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 286025 POWERLINK V2: Large fluctuationsof IEEE 1588 Nettime (used for safety logbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(15374), 1\7669b0.can(122), 1\7669b0.epl(60) Version 1.2.0.2: ID: 256805 / Support ID: 400057319 POWERLINK: In controlled node mode, the I/O mapping was not applied when the manager was restarted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 256915 POWERLINK: LinkOK data point added. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 256960 POWERLINK: The net time is not always transferred correctly to the application. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 257050 POWERLINK: Support for 100 Mbit full duplex in Ethernet operating mode. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 265695 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265900 POWERLINK V2: If the the Ready-Flag was canceled on the network, the ModuleOK was not cleared. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265795 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with "Chaned Station" on the same network Error correction: When an iCNis used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning is that the sync response frames that are used to measure the timing of the "Chained Station"are not recognized by the iCN. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(14861), 1\7669b0.can(122), 1\7669b0.epl(58) Version 1.1.13.0: ID: 226710 / Support ID: 400041497 Problems starting CAN-FW corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13324), 1\7669b0.can(122), 1\7669b0.epl(52) Version 1.1.12.0: ID: 230840 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13323), 1\7669b0.can(122), 1\7669b0.epl(52) Version 1.1.11.0: ID: 229065 CAN transmitter blockade after cable un-/plugged corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13067), 1\7669b0.can(122), 1\7669b0.epl(51) Version 1.1.10.0: ID: 224445 CAN TransmitQueue Reset command corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13067), 1\7669b0.can(120), 1\7669b0.epl(51) Version 1.1.9.0: ID: 220435 POWERLINK V2: Boot behavior improved Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13067), 1\7669b0.can(117), 1\7669b0.epl(51) Version 1.1.8.0: ID: 213030 CN mode: Various error corrections made. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(12043), 1\7669b0.can(117), 1\7669b0.epl(47) Version 1.1.7.0: ID: 206910 New POWERLINK firmware V45 and basis firmware V11 POWERLINK V2 CN mode: - Frequent MN failures result in CPU going into Service mode. - ThePollResponse data from multiplexed stations are now updated in every POWERLINK cycle. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(11531), 1\7669b0.can(117), 1\7669b0.epl(45) Version 1.1.6.0: ID: 199525 New POWERLINK V1/V2 firmware V44 CN mode: Various error corrections made. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(11274), 1\7669b0.can(117), 1\7669b0.epl(44) Version 1.1.5.1: ID: 191750 New POWERLINK V1/V2 Firmware V42 and basis firmware V10 - Error correction for POWERLINK V2: After network disturbances, failed stations were left out ofcyclic traffic. - Error correction POWERLINK V2 CN mode: Failure of a SoC resulted immediately in incorrect failure detection by manager. Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(10762), 1\7669b0.can(117), 1\7669b0.epl(42) Version 1.1.4.0: ID: 185600 New POWERLINK V1/V2firmware V39 and basis firmware V9 - Error correction for POWERLINK V2: Certain configurations may cause multiplexed stations to fail. - Error correction for POWERLINK V2: An error while switching the alternating buffer caused old input data to be resent. (This error only occurred with upgrade 1.1.3.0.) - Error correction: In configurations with a large amount of I/O data, incorrect input data was sent. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9993), 1\7669b0.can(117), 1\7669b0.epl(39) Version 1.1.3.0: ID: 183640 New POWERLINK V1/V2 firmware V38 and basis firmware V8 - Error correction for POWERLINK V2: Parameter "CycleIdleTime" was not calculated correctly. - Error correction: ModbusTCP on POWERLINK interfaces was not working. - Improved stability for network disturbances. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9736), 1\7669b0.can(117), 1\7669b0.epl(38) Version 1.1.2.0: ID: 178025 New POWERLINK V1/V2 firmware V37 and base firmware V6 Error corrections: - POWERLINK V2 CN mode: Various error corrections made. - Asynchronous scheduler: The host has only sent an asynchronous frame in max. every second cycle. - POWERLILNK V2: Asynchronous frames can now be received with the Powerlinklibrary starting with channel >= 0x20 (previously starting with 0xA0). Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9478), 1\7669b0.can(117), 1\7669b0.epl(37) Version 1.1.1.0: ID: 173335 New POWERLINK firmware V36 Error correction: - When using an I/O prescaler > 1, in certain circumstances the old input data for the station is provided to the application. - ISSI-RAMs are supported. Changes - POWERLINK V2: - The poll response from the manager is now sent at the beginning of the POWERLINK cycle. - From now on, stations are addressed with poll requests starting in status"PreOperational 2". Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9221), 1\7669b0.can(117), 1\7669b0.epl(36) Version 1.1.0.0: ID: 171125 Performance improvement - POWERLINK manager Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8964), 1\7669b0.can(117), 1\7669b0.epl(35) Version 1.0.6.0: ID: 167027 5LS187.6-1 doesn't works with Automation Runtime >= 2.92 Channel description changed:No Configuration description changed: No Firmware changed: No ID: 167200 New base firmware V3 Collisions resulted in transmission of invalid frames. Channel description changed: No Configurationdescription changed: No Firmware changed: No Firmware: 1\7669_0.pci(8707), 1\7669b0.can(117), 1\7669b0.epl(34) Version 1.0.5.0: ID: 165815 New POWERLINK V1/V2 Firmware V34 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8706), 1\7669b0.can(117), 1\7669b0.epl(34) Version 1.0.4.0: ID: 165455 New POWERLINK V1/V2 Firmware V33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8450), 1\7669b0.epl(33) Version 1.0.3.0: ID: 164770 New POWERLINK V1/V2 Firmware V31 - Optimizations for EPL V2 startup carried out. - Nettime IEEE 1588for EPL V2 implemented. - From now on, the asynchronous scheduler will handle asynchronous requestsbased on their priority. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(7938), 1\7669b0.epl(31) Version 1.0.1.0: ID: 160755 New Firmware V30 In "Controlled Node" mode, thefollowing errors may occur: - With heavy asynchronous loads, asynchronous TX packets may be lost. - Collisions on the network can cause the station to stop receiving Ethernet packets. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(7682), 1\7669b0.epl(30) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.6.0.0 | * | 16/06/2023 | 2 Mo | EXE | AS4_HW_5LS187.6-1.exe | |
Description |
V4.0 HW Upgrade (5LS187.6-1) Revision information 5LS187.6-1 Version 1.6.0.0: ID: 735735 Update problem If the firmware update of the interface card was interrupted (e.g. by a power failure), it was possible that the interface was no longer booted by Automation Runtime. Thisproblem can only occur with interfaces with revisions smaller than H0 andwhen the hardware upgrade is changed. To correct this problem, it is necessaryto switch to another hardware upgrade. This will force an update or use this current hardware upgrade. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 770535 Resolve potential loss of remanent data Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(18195), 1\7669_1.pci(18182), 1\7669b0.can(130), 1\7669b1.can(0), 1\7669b0.epl(71), 1\7669b1.epl(71) Version 1.5.0.0: ID: 730435 Support HW variant 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\7669_0.pci(17938), 1\7669_1.pci(17923), 1\7669b0.can(130), 1\7669b1.can(0),1\7669b0.epl(70), 1\7669b1.epl(70) Version 1.4.1.0: ID: 699115 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 699220 Module documentation revised Data sheet V 1.20 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 1\7669_0.pci(17682), 1\7669b0.can(130), 1\7669b0.epl(69) Version 1.4.0.0: ID: 686305 Corrected handling of RTR objects Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(17682), 1\7669b0.can(130), 1\7669b0.epl(69) Version 1.3.0.0: ID: 442030 / Support ID: 0 POWERLINK V2 operating mode: managing node An error is causing higher transfer times on the PCI bus that are resultingin POWERLINK and I/O cycle time violations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(17170), 1\7669b0.can(122), 1\7669b0.epl(67) Version 1.2.7.0: ID: 429220 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 429240 / Support ID: 400151182 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16914), 1\7669b0.can(122), 1\7669b0.epl(66) Version 1.2.6.0: ID: 391580 Possibly incorrect display of the Powerlink status LEDs Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16402), 1\7669b0.can(122), 1\7669b0.epl(64) Version 1.2.5.0: ID: 376441 / Support ID: 400120997 Module sporadically not recognized in APC910 when booting Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16401), 1\7669b0.can(122), 1\7669b0.epl(64) Version 1.2.4.0: ID: 358935 POWERLINK MN mode: If "Multiplexing prescale" >= 9, then the input data of themultiplexed stations that were configured in the last "network cycle" were not transferred in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 359160 / Support ID: 400113446 POWERLINK V2 MN mode: Asynchronous connection losses may occur as a result of high asynchronous loads on the POWERLINK network and high loads on the CPU. This could maintain you to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.2.3.0: ID: 332305 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 336710 POWERLINK V2 MN mode: It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337445 / Support ID: 400108118 POWERLINK V2 CN mode It waspossible that an undefined state occurred during booting that caused the interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16143), 1\7669b0.can(122), 1\7669b0.epl(63) Version 1.2.2.0: ID: 294795 / Support ID: 400070288 Update problem by plc restart Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\7669_0.pci(15375), 1\7669b0.can(122), 1\7669b0.epl(60) Version 1.2.1.0: ID: 285945 POWERLINK V2 CN mode:Asynchronous packets lost when there is a large asynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 286025 POWERLINK V2: Large fluctuations of IEEE 1588 Nettime (used for safety logbook entries) during startup. Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(15374), 1\7669b0.can(122), 1\7669b0.epl(60) Version 1.2.0.2: ID: 256805 / Support ID: 400057319 POWERLINK: In controlled node mode, the I/O mapping was not applied when the manager was restarted. Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 256915 POWERLINK: LinkOK data point added. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 256960 POWERLINK: The net time is not always transferred correctly to the application. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 257050 POWERLINK: Support for 100 Mbit full duplex in Ethernet operating mode. Channel description changed: No Configurationdescription changed: Yes Firmware changed: Yes ID: 265695 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265900 POWERLINK V2: If thethe Ready-Flag was canceled on the network, the ModuleOK was not cleared. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265795 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with "Chaned Station" on the same network Error correction: When an iCN is used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason forthis warning is that the sync response frames that are used to measure the timing of the "Chained Station" are not recognized by the iCN. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(14861), 1\7669b0.can(122), 1\7669b0.epl(58) Version 1.1.13.0: ID: 226710 / Support ID: 400041497 Problems starting CAN-FW corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13324), 1\7669b0.can(122), 1\7669b0.epl(52) Version 1.1.12.0: ID: 230840 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13323), 1\7669b0.can(122), 1\7669b0.epl(52) Version 1.1.11.0: ID: 229065 CAN transmitter blockade after cable un-/plugged corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13067), 1\7669b0.can(122), 1\7669b0.epl(51) Version 1.1.10.0: ID: 224445 CAN TransmitQueue Reset command corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13067), 1\7669b0.can(120), 1\7669b0.epl(51) Version 1.1.9.0: ID: 220435 POWERLINK V2: Boot behavior improved Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\7669_0.pci(13067), 1\7669b0.can(117), 1\7669b0.epl(51) Version 1.1.8.0: ID: 213030 CN mode: Various error corrections made. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(12043), 1\7669b0.can(117), 1\7669b0.epl(47) Version 1.1.7.0: ID: 206910 New POWERLINK firmware V45 and basis firmware V11 POWERLINK V2 CN mode: - Frequent MN failures result in CPU going into Service mode. - The PollResponse data from multiplexed stations are now updated in every POWERLINK cycle. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(11531), 1\7669b0.can(117), 1\7669b0.epl(45) Version 1.1.6.0: ID: 199525 New POWERLINK V1/V2 firmware V44 CN mode:Various error corrections made. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(11274), 1\7669b0.can(117), 1\7669b0.epl(44) Version 1.1.5.1: ID: 191750 New POWERLINK V1/V2 Firmware V42 and basis firmwareV10 - Error correction for POWERLINK V2: After network disturbances, failed stations were left out of cyclic traffic. - Error correction POWERLINK V2 CN mode: Failure of a SoC resulted immediately in incorrect failure detection by manager. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(10762), 1\7669b0.can(117), 1\7669b0.epl(42) Version 1.1.4.0: ID: 185600 New POWERLINK V1/V2 firmware V39 and basis firmware V9 - Error correction for POWERLINK V2: Certain configurations may cause multiplexed stations to fail. - Error correction for POWERLINK V2: An error while switching the alternating buffer caused old input data to be resent. (This error onlyoccurred with upgrade 1.1.3.0.) - Error correction: In configurations with a large amount of I/O data, incorrect input data was sent. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9993), 1\7669b0.can(117), 1\7669b0.epl(39) Version 1.1.3.0: ID: 183640 New POWERLINK V1/V2 firmware V38 and basis firmware V8 - Error correction for POWERLINK V2: Parameter "CycleIdleTime" was not calculated correctly. - Error correction: ModbusTCP on POWERLINK interfaces was not working. - Improved stability fornetwork disturbances. Channel description changed: No Configurationdescription changed: No Firmware changed: No Firmware: 1\7669_0.pci(9736), 1\7669b0.can(117), 1\7669b0.epl(38) Version 1.1.2.0: ID: 178025 New POWERLINK V1/V2 firmware V37 and base firmware V6 Error corrections: - POWERLINK V2 CN mode: Various error corrections made. - Asynchronous scheduler: The host has only sent an asynchronous frame in max. every second cycle. - POWERLILNK V2: Asynchronous frames can now be received with the Powerlinklibrary starting with channel >= 0x20 (previously starting with 0xA0). Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9478), 1\7669b0.can(117), 1\7669b0.epl(37) Version 1.1.1.0: ID: 173335 New POWERLINK firmware V36 Error correction: - When using an I/O prescaler > 1, in certain circumstances the old input data for the station is provided to the application. - ISSI-RAMs are supported. Changes - POWERLINK V2: - The poll response from the manager is now sent at the beginning of the POWERLINK cycle. - From now on, stations are addressed with poll requests starting in status"PreOperational 2". Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9221), 1\7669b0.can(117), 1\7669b0.epl(36) Version 1.1.0.0: ID: 171125 Performance improvement - POWERLINK manager Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8964), 1\7669b0.can(117), 1\7669b0.epl(35) Version 1.0.6.0: ID: 167027 5LS187.6-1 doesn't works with Automation Runtime >= 2.92 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 167200 New base firmware V3 Collisions resulted in transmission of invalid frames. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8707), 1\7669b0.can(117), 1\7669b0.epl(34) Version 1.0.5.0: ID: 165815 New POWERLINK V1/V2 Firmware V34 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8706), 1\7669b0.can(117), 1\7669b0.epl(34) Version 1.0.4.0: ID: 165455 New POWERLINK V1/V2 Firmware V33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8450), 1\7669b0.epl(33) Version 1.0.3.0: ID: 164770 NewPOWERLINK V1/V2 Firmware V31 - Optimizations for EPL V2 startup carried out. - Nettime IEEE 1588 for EPL V2 implemented. - From now on, the asynchronous scheduler will handle asynchronous requestsbased on their priority. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(7938), 1\7669b0.epl(31) Version 1.0.1.0: ID: 160755 New Firmware V30 In "Controlled Node" mode, the following errors may occur: - With heavy asynchronous loads, asynchronous TX packets may be lost. - Collisions on the network can cause the station to stop receiving Ethernet packets. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(7682), 1\7669b0.epl(30) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.5.0.0 | * | 23/07/2021 | 2 Mo | EXE | AS4_HW_5LS187.6-1.exe | |
Description |
V4.0 HW Upgrade (5LS187.6-1) Revision information 5LS187.6-1.6-1 Version 1.5.0.0: ID: 730435 Support HW variant 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(17938), 1\7669_1.pci(17923), 1\7669b0.can(130), 1\7669b1.can(0), 1\7669b0.epl(70), 1\7669b1.epl(70) Version 1.4.1.0: ID: 699115 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 699220 Module documentation revised Data sheet V 1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(17682), 1\7669b0.can(130), 1\7669b0.epl(69) Version 1.4.0.0: ID: 686305 Corrected handling of RTR objects Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(17682), 1\7669b0.can(130), 1\7669b0.epl(69) Version 1.3.0.0: ID: 442030 / Support ID: 0 POWERLINK V2 operating mode: managing node An error is causing higher transfer times on the PCI bus that are resultingin POWERLINK and I/O cycle time violations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(17170), 1\7669b0.can(122), 1\7669b0.epl(67) Version 1.2.7.0: ID: 429220 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 429240/ Support ID: 400151182 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16914), 1\7669b0.can(122), 1\7669b0.epl(66) Version 1.2.6.0: ID: 391580 Possibly incorrect displayof the Powerlink status LEDs Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16402), 1\7669b0.can(122), 1\7669b0.epl(64) Version 1.2.5.0: ID: 376441 / Support ID: 400120997 Module sporadically not recognized in APC910 when booting Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16401), 1\7669b0.can(122), 1\7669b0.epl(64) Version 1.2.4.0: ID: 358935 POWERLINK MN mode: If "Multiplexing prescale" >=9, then the input data of the multiplexed stations that were configured in the last "network cycle" were not transferred in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 359160 / Support ID: 400113446 POWERLINK V2 MN mode: Asynchronous connection losses may occur as a result of high asynchronous loads on the POWERLINK network and high loads on the CPU. This could maintain you to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Version 1.2.3.0: ID: 332305 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronouscommunication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 336710 POWERLINK V2 MN mode: It was possible that anundefined state occurred during booting that caused the interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337445 / Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16143), 1\7669b0.can(122), 1\7669b0.epl(63) Version 1.2.2.0: ID: 294795 / Support ID: 400070288 Update problem by plc restart Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(15375), 1\7669b0.can(122), 1\7669b0.epl(60) Version 1.2.1.0: ID: 285945 POWERLINK V2 CN mode: Asynchronous packets lost when there is a largeasynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 286025 POWERLINK V2: Large fluctuations of IEEE 1588 Nettime (used for safety logbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(15374), 1\7669b0.can(122), 1\7669b0.epl(60) Version 1.2.0.2: ID: 256805 / Support ID: 400057319 POWERLINK: In controlled node mode, the I/O mapping was not applied when the manager was restarted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 256915 POWERLINK: LinkOK data point added. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 256960 POWERLINK: The net time is not always transferred correctly to the application. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 257050 POWERLINK: Support for 100 Mbit full duplex in Ethernet operating mode. Channel description changed: No Configuration description changed: Yes Firmware changed:Yes ID: 265695 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265900 POWERLINK V2: If the the Ready-Flag was canceled on the network, theModuleOK was not cleared. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265795 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with "Chaned Station" on the same network Error correction: When an iCN is used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning is that the sync response frames that are used to measure the timing of the "Chained Station" are not recognizedby the iCN. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(14861), 1\7669b0.can(122), 1\7669b0.epl(58) Version 1.1.13.0: ID: 226710 / Support ID: 400041497 Problems starting CAN-FW corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13324), 1\7669b0.can(122), 1\7669b0.epl(52) Version 1.1.12.0: ID: 230840 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13323), 1\7669b0.can(122), 1\7669b0.epl(52) Version 1.1.11.0: ID: 229065 CAN transmitter blockade after cable un-/plugged corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13067), 1\7669b0.can(122), 1\7669b0.epl(51) Version 1.1.10.0: ID: 224445 CAN TransmitQueue Reset command corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13067), 1\7669b0.can(120), 1\7669b0.epl(51) Version 1.1.9.0: ID: 220435 POWERLINK V2: Boot behavior improved Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13067), 1\7669b0.can(117), 1\7669b0.epl(51) Version 1.1.8.0: ID: 213030 CN mode: Various error corrections made. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(12043), 1\7669b0.can(117), 1\7669b0.epl(47) Version 1.1.7.0: ID: 206910 New POWERLINK firmware V45 and basis firmware V11 POWERLINK V2 CN mode: - Frequent MNfailures result in CPU going into Service mode. - The PollResponse data from multiplexed stations are now updated in every POWERLINK cycle. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(11531), 1\7669b0.can(117), 1\7669b0.epl(45) Version 1.1.6.0: ID: 199525 New POWERLINK V1/V2 firmware V44 CN mode: Various error corrections made. Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\7669_0.pci(11274), 1\7669b0.can(117), 1\7669b0.epl(44) Version 1.1.5.1: ID: 191750 New POWERLINK V1/V2 Firmware V42 and basis firmware V10 - Error correction for POWERLINK V2: After network disturbances, failed stations were left out of cyclic traffic. - Error correction POWERLINK V2 CN mode: Failure of a SoC resulted immediately in incorrect failure detection by manager. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(10762), 1\7669b0.can(117), 1\7669b0.epl(42) Version 1.1.4.0: ID: 185600 New POWERLINK V1/V2 firmware V39 and basis firmware V9 - Error correction for POWERLINK V2: Certain configurations may cause multiplexed stations to fail. - Error correction for POWERLINK V2: An error while switching the alternating buffer caused old input data to be resent. (This error only occurred with upgrade 1.1.3.0.) - Error correction: In configurations with a large amount of I/O data, incorrect input data was sent. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9993), 1\7669b0.can(117), 1\7669b0.epl(39) Version 1.1.3.0: ID: 183640 New POWERLINK V1/V2 firmware V38 and basis firmware V8 - Error correction for POWERLINK V2: Parameter "CycleIdleTime" was not calculated correctly. - Error correction: ModbusTCP on POWERLINK interfaces was not working. - Improved stability for network disturbances. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9736), 1\7669b0.can(117), 1\7669b0.epl(38) Version 1.1.2.0: ID: 178025 New POWERLINK V1/V2 firmware V37 and base firmware V6 Error corrections: - POWERLINK V2 CN mode: Various error corrections made. - Asynchronous scheduler: The host has only sent an asynchronous frame in max. every second cycle. - POWERLILNK V2: Asynchronous frames can now be received with the Powerlinklibrary starting withchannel >= 0x20 (previously starting with 0xA0). Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9478), 1\7669b0.can(117), 1\7669b0.epl(37) Version 1.1.1.0: ID: 173335 New POWERLINK firmware V36 Error correction: - When using an I/O prescaler > 1, in certain circumstancesthe old input data for the station is provided to the application. - ISSI-RAMs are supported. Changes - POWERLINK V2: - The poll response from the manager is now sent at the beginning of the POWERLINK cycle. - From now on, stations are addressed with poll requests starting in status"PreOperational 2". Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9221), 1\7669b0.can(117), 1\7669b0.epl(36) Version 1.1.0.0: ID: 171125 Performance improvement - POWERLINK manager Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8964), 1\7669b0.can(117), 1\7669b0.epl(35) Version 1.0.6.0: ID: 167027 5LS187.6-1 doesn't works with Automation Runtime >= 2.92 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 167200 New base firmware V3 Collisions resulted in transmission of invalid frames. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8707), 1\7669b0.can(117), 1\7669b0.epl(34) Version 1.0.5.0: ID: 165815 New POWERLINK V1/V2 Firmware V34 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8706), 1\7669b0.can(117), 1\7669b0.epl(34) Version 1.0.4.0: ID: 165455 New POWERLINK V1/V2 Firmware V33 Channel descriptionchanged: No Configuration description changed: No Firmware changed:No Firmware: 1\7669_0.pci(8450), 1\7669b0.epl(33) Version 1.0.3.0: ID: 164770 New POWERLINK V1/V2 Firmware V31 - Optimizations for EPL V2 startup carried out. - Nettime IEEE 1588 for EPL V2 implemented. - From now on, the asynchronous scheduler will handle asynchronous requestsbased on their priority. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(7938), 1\7669b0.epl(31) Version 1.0.1.0: ID: 160755 New Firmware V30 In "Controlled Node" mode, the following errors may occur: - With heavy asynchronous loads, asynchronous TX packets may belost. - Collisions on the network can cause the station to stop receiving Ethernet packets. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(7682), 1\7669b0.epl(30) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.4.1.0 | * | 04/09/2020 | 2 Mo | EXE | AS4_HW_5LS187.6-1.exe | |
Description |
V4.0 HW Upgrade (5LS187.6-1) Revision information 5LS187.6-1 Version 1.4.1.0: ID: 699115 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 699220 Module documentation revised Data sheet V 1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(17682), 1\7669b0.can(130), 1\7669b0.epl(69) Version 1.4.0.0: ID: 686305 Corrected handling of RTR objects Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(17682), 1\7669b0.can(130), 1\7669b0.epl(69) Version 1.3.0.0: ID: 442030 / Support ID: 0 POWERLINK V2 operating mode: managing node An error is causing higher transfer times on the PCI bus that are resultingin POWERLINK and I/O cycle time violations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(17170), 1\7669b0.can(122), 1\7669b0.epl(67) Version 1.2.7.0: ID: 429220 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 429240 / Support ID: 400151182 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16914), 1\7669b0.can(122), 1\7669b0.epl(66) Version 1.2.6.0: ID: 391580 Possibly incorrect display of the Powerlink status LEDs Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16402), 1\7669b0.can(122), 1\7669b0.epl(64) Version 1.2.5.0: ID: 376441 / Support ID: 400120997 Module sporadically not recognized in APC910 when booting Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16401), 1\7669b0.can(122), 1\7669b0.epl(64) Version 1.2.4.0: ID: 358935 POWERLINK MN mode: If "Multiplexing prescale" >= 9, then the input data of the multiplexed stations that were configured inthe last "network cycle" were not transferred in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 359160 / Support ID: 400113446 POWERLINK V2 MN mode: Asynchronous connection losses may occur as a result ofhigh asynchronous loads on the POWERLINK network and high loads on the CPU. This could maintain you to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.2.3.0: ID: 332305 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 336710 POWERLINK V2 MN mode: It was possible thatan undefined state occurred during booting that caused the interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337445 / Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16143), 1\7669b0.can(122), 1\7669b0.epl(63) Version 1.2.2.0: ID: 294795 / Support ID: 400070288 Update problem by plc restart Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(15375), 1\7669b0.can(122), 1\7669b0.epl(60) Version 1.2.1.0: ID: 285945 POWERLINK V2 CN mode: Asynchronous packets lost when there is a large asynchronous load with large asynchronous frames. Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 286025 POWERLINK V2: Large fluctuations of IEEE 1588 Nettime (used for safety logbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(15374), 1\7669b0.can(122), 1\7669b0.epl(60) Version 1.2.0.2: ID: 256805 / Support ID: 400057319 POWERLINK: In controlled node mode, the I/O mapping was not applied when the manager was restarted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 256915 POWERLINK: LinkOK data point added. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 256960 POWERLINK: The net time is not always transferred correctly to the application. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 257050 POWERLINK: Support for 100 Mbit full duplex in Ethernet operating mode. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 265695 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:265900 POWERLINK V2: If the the Ready-Flag was canceled on the network, the ModuleOK was not cleared. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265795 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with "Chaned Station" on the same network Error correction: When an iCN is used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning is that the sync response frames that are used to measure the timing of the "Chained Station" are not recognized by the iCN. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(14861), 1\7669b0.can(122), 1\7669b0.epl(58) Version 1.1.13.0: ID: 226710 / Support ID: 400041497 Problems starting CAN-FW corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13324), 1\7669b0.can(122), 1\7669b0.epl(52) Version 1.1.12.0: ID: 230840 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13323), 1\7669b0.can(122), 1\7669b0.epl(52) Version 1.1.11.0: ID: 229065 CAN transmitter blockade after cable un-/plugged corrected Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13067), 1\7669b0.can(122), 1\7669b0.epl(51) Version 1.1.10.0: ID: 224445 CAN TransmitQueue Reset command corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13067), 1\7669b0.can(120), 1\7669b0.epl(51) Version 1.1.9.0: ID: 220435 POWERLINK V2: Boot behavior improved Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\7669_0.pci(13067), 1\7669b0.can(117), 1\7669b0.epl(51) Version 1.1.8.0: ID: 213030 CN mode: Various error corrections made. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(12043), 1\7669b0.can(117), 1\7669b0.epl(47) Version 1.1.7.0: ID: 206910 New POWERLINK firmware V45 and basis firmware V11 POWERLINK V2 CN mode: - FrequentMN failures result in CPU going into Service mode. - The PollResponse data from multiplexed stations are now updated in every POWERLINK cycle. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(11531), 1\7669b0.can(117), 1\7669b0.epl(45) Version 1.1.6.0: ID: 199525 New POWERLINKV1/V2 firmware V44 CN mode: Various error corrections made. Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(11274), 1\7669b0.can(117), 1\7669b0.epl(44) Version 1.1.5.1: ID: 191750 New POWERLINK V1/V2 Firmware V42 and basis firmware V10 - Error correction for POWERLINK V2: After network disturbances, failed stations were left out of cyclic traffic. - Error correction POWERLINK V2 CN mode: Failure of a SoC resulted immediately in incorrect failure detection by manager. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(10762), 1\7669b0.can(117), 1\7669b0.epl(42) Version 1.1.4.0: ID: 185600 New POWERLINK V1/V2 firmware V39 and basis firmware V9 - Error correction for POWERLINK V2: Certain configurations may cause multiplexed stations to fail. - Error correction for POWERLINK V2: An error while switching the alternating buffer caused old input data to be resent. (This error only occurred with upgrade 1.1.3.0.) - Errorcorrection: In configurations with a large amount of I/O data, incorrect input data was sent. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9993), 1\7669b0.can(117), 1\7669b0.epl(39) Version 1.1.3.0: ID: 183640 New POWERLINK V1/V2 firmware V38 and basis firmware V8 - Error correction for POWERLINK V2: Parameter "CycleIdleTime" was not calculated correctly. - Error correction: ModbusTCP on POWERLINK interfaces was not working. - Improved stability for network disturbances. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9736), 1\7669b0.can(117), 1\7669b0.epl(38) Version 1.1.2.0: ID: 178025 New POWERLINK V1/V2 firmware V37 and base firmware V6 Error corrections: - POWERLINK V2 CN mode: Various error corrections made. - Asynchronous scheduler: The host has only sent an asynchronous frame in max. every second cycle. - POWERLILNK V2:Asynchronous frames can now be received with the Powerlink library starting with channel >= 0x20 (previously starting with 0xA0). Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9478), 1\7669b0.can(117), 1\7669b0.epl(37) Version 1.1.1.0: ID: 173335 New POWERLINK firmware V36 Error correction: - When using an I/O prescaler > 1, in certain circumstances the old input data for the station is provided to the application. - ISSI-RAMs are supported. Changes - POWERLINK V2: - The poll response from the manager is now sent at the beginning of the POWERLINK cycle. - From now on, stations are addressed with poll requests starting in status"PreOperational 2". Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9221), 1\7669b0.can(117), 1\7669b0.epl(36) Version 1.1.0.0: ID: 171125 Performance improvement - POWERLINK manager Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8964), 1\7669b0.can(117), 1\7669b0.epl(35) Version 1.0.6.0: ID: 167027 5LS187.6-1 doesn't works with Automation Runtime >= 2.92 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 167200 New base firmware V3 Collisions resulted in transmission of invalid frames. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8707), 1\7669b0.can(117), 1\7669b0.epl(34) Version 1.0.5.0: ID: 165815 New POWERLINK V1/V2 Firmware V34 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8706), 1\7669b0.can(117), 1\7669b0.epl(34) Version 1.0.4.0: ID: 165455 New POWERLINK V1/V2 Firmware V33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8450), 1\7669b0.epl(33) Version 1.0.3.0: ID: 164770 New POWERLINK V1/V2 Firmware V31 - Optimizations for EPL V2 startup carried out. - Nettime IEEE 1588 for EPL V2 implemented. - From now on, the asynchronous scheduler will handle asynchronous requestsbased on their priority. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(7938), 1\7669b0.epl(31) Version 1.0.1.0: ID: 160755 New Firmware V30 In "Controlled Node" mode, the following errors may occur: - With heavy asynchronous loads, asynchronous TX packets maybe lost. - Collisions on the network can cause the station to stop receiving Ethernet packets. Channel description changed: No Configurationdescription changed: No Firmware changed: No Firmware: 1\7669_0.pci(7682), 1\7669b0.epl(30) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.4.0.0 | * | 09/06/2020 | 510 Ko | EXE | AS4_HW_5LS187.6-1.exe | |
Description |
V4.0 HW Upgrade (5LS187.6-1) Revision information 5LS187.6-1 Version 1.4.0.0: ID: 686305 Corrected handling of RTR objects Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(17682), 1\7669b0.can(130), 1\7669b0.epl(69) Version 1.3.0.0: ID: 442030 / Support ID: 0 POWERLINK V2 operating mode: managing node An error is causing higher transfer times on the PCI bus that are resultingin POWERLINK and I/O cycletime violations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(17170), 1\7669b0.can(122), 1\7669b0.epl(67) Version 1.2.7.0: ID: 429220 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 429240 / Support ID: 400151182 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes causeda permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16914), 1\7669b0.can(122), 1\7669b0.epl(66) Version 1.2.6.0: ID: 391580 Possibly incorrect display of the Powerlink status LEDs Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16402), 1\7669b0.can(122), 1\7669b0.epl(64) Version 1.2.5.0: ID: 376441 / Support ID: 400120997 Module sporadically not recognized in APC910 when booting Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16401), 1\7669b0.can(122), 1\7669b0.epl(64) Version 1.2.4.0: ID: 358935 POWERLINK MN mode: If "Multiplexing prescale">= 9, then the input data of the multiplexed stations that were configuredin the last "network cycle" were not transferred in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 359160 / Support ID: 400113446 POWERLINK V2 MN mode: Asynchronous connection losses may occur as a resultof high asynchronous loads on the POWERLINK network and high loads on the CPU. This could maintain you to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.2.3.0: ID: 332305 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINKV2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 336710 POWERLINK V2 MN mode: It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337445 / Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurredduring booting that caused the interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16143), 1\7669b0.can(122), 1\7669b0.epl(63) Version 1.2.2.0: ID: 294795 / Support ID: 400070288 Update problem by plc restart Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(15375), 1\7669b0.can(122), 1\7669b0.epl(60) Version 1.2.1.0: ID: 285945 POWERLINK V2 CN mode: Asynchronous packets lost when there is alarge asynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 286025 POWERLINK V2: Large fluctuations of IEEE 1588Nettime (used for safety logbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(15374), 1\7669b0.can(122), 1\7669b0.epl(60) Version 1.2.0.2: ID: 256805 / Support ID: 400057319 POWERLINK: In controlled node mode, the I/O mapping was not applied when the manager was restarted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 256915 POWERLINK: LinkOK data point added. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 256960 POWERLINK: The net time is not always transferred correctly to the application. Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 257050 POWERLINK: Support for 100 Mbit full duplex in Ethernet operating mode. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 265695 POWERLINK V2 CN mode: Frequent MN failuresresult in CPU going into Service mode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265900 POWERLINK V2: If the the Ready-Flag was canceled on the network, the ModuleOK was not cleared. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265795 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with "Chaned Station" on the same network Error correction: When an iCN is used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning is that the sync response frames that are used to measure the timing of the "Chained Station" are not recognized by the iCN. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(14861), 1\7669b0.can(122), 1\7669b0.epl(58) Version 1.1.13.0: ID: 226710 / Support ID: 400041497 Problems starting CAN-FW corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13324), 1\7669b0.can(122),1\7669b0.epl(52) Version 1.1.12.0: ID: 230840 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13323), 1\7669b0.can(122), 1\7669b0.epl(52) Version 1.1.11.0: ID: 229065 CAN transmitter blockade after cable un-/plugged corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13067), 1\7669b0.can(122), 1\7669b0.epl(51) Version 1.1.10.0: ID: 224445 CAN TransmitQueue Reset command corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13067), 1\7669b0.can(120), 1\7669b0.epl(51) Version 1.1.9.0: ID: 220435 POWERLINK V2: Boot behavior improved Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13067), 1\7669b0.can(117), 1\7669b0.epl(51) Version 1.1.8.0: ID: 213030 CN mode: Various error corrections made. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(12043), 1\7669b0.can(117),1\7669b0.epl(47) Version 1.1.7.0: ID: 206910 New POWERLINK firmware V45 and basis firmware V11 POWERLINK V2 CN mode: - Frequent MN failures result in CPU going into Service mode. - The PollResponsedata from multiplexed stations are now updated in every POWERLINK cycle. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(11531), 1\7669b0.can(117), 1\7669b0.epl(45) Version 1.1.6.0: ID: 199525 New POWERLINK V1/V2 firmware V44 CN mode: Various error corrections made. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(11274), 1\7669b0.can(117), 1\7669b0.epl(44) Version 1.1.5.1: ID: 191750 New POWERLINK V1/V2 Firmware V42 and basis firmware V10 - Error correction for POWERLINKV2: After network disturbances, failed stations were left out of cyclic traffic. - Error correction POWERLINK V2 CN mode: Failure of a SoC resulted immediately in incorrect failure detection by manager. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(10762), 1\7669b0.can(117), 1\7669b0.epl(42) Version 1.1.4.0: ID: 185600 New POWERLINK V1/V2 firmware V39and basis firmware V9 - Error correction for POWERLINK V2: Certain configurations may cause multiplexed stations to fail. - Error correction for POWERLINK V2: An error while switching the alternating buffer caused old inputdata to be resent. (This error only occurred with upgrade 1.1.3.0.) - Error correction: In configurations with a large amount of I/O data, incorrect input data was sent. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9993), 1\7669b0.can(117), 1\7669b0.epl(39) Version 1.1.3.0: ID: 183640 New POWERLINK V1/V2 firmware V38 and basis firmware V8 - Error correction for POWERLINK V2: Parameter "CycleIdleTime" was not calculated correctly. - Error correction: ModbusTCP on POWERLINK interfaces was not working. - Improved stability for network disturbances. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9736), 1\7669b0.can(117), 1\7669b0.epl(38) Version 1.1.2.0: ID: 178025 New POWERLINK V1/V2 firmware V37 and base firmware V6 Error corrections: - POWERLINK V2 CN mode: Various error corrections made. - Asynchronous scheduler: The host has only sent an asynchronous frame in max. every second cycle. - POWERLILNK V2: Asynchronous frames can now be received with the Powerlinklibrary starting with channel >= 0x20 (previously starting with 0xA0). Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9478), 1\7669b0.can(117), 1\7669b0.epl(37) Version 1.1.1.0: ID: 173335 New POWERLINK firmware V36 Error correction: - When using an I/O prescaler > 1, in certain circumstances the old input data for the station is provided to the application. - ISSI-RAMs are supported. Changes - POWERLINK V2: - The pollresponse from the manager is now sent at the beginning of the POWERLINK cycle. - From now on, stations are addressed with poll requests starting in status"PreOperational 2". Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9221), 1\7669b0.can(117), 1\7669b0.epl(36) Version 1.1.0.0: ID: 171125 Performance improvement - POWERLINK manager Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8964), 1\7669b0.can(117), 1\7669b0.epl(35) Version 1.0.6.0: ID: 167027 5LS187.6-1 doesn't works with Automation Runtime >= 2.92 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 167200 New base firmware V3 Collisions resulted in transmission of invalid frames. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8707), 1\7669b0.can(117), 1\7669b0.epl(34) Version 1.0.5.0: ID: 165815 New POWERLINK V1/V2 Firmware V34 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8706), 1\7669b0.can(117), 1\7669b0.epl(34) Version 1.0.4.0: ID: 165455 New POWERLINK V1/V2 Firmware V33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8450), 1\7669b0.epl(33) Version 1.0.3.0: ID: 164770 New POWERLINK V1/V2 Firmware V31 - Optimizations for EPL V2 startup carried out. - Nettime IEEE 1588 for EPL V2 implemented. - From now on, the asynchronous scheduler will handle asynchronous requestsbased on their priority. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(7938), 1\7669b0.epl(31) Version 1.0.1.0: ID:160755 New Firmware V30 In "Controlled Node" mode, the following errors may occur: - With heavy asynchronous loads, asynchronous TX packets may be lost. - Collisions on the network can cause the station to stop receiving Ethernet packets. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(7682), 1\7669b0.epl(30) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.3.0.0 | * | 10/09/2015 | 529 Ko | EXE | AS4_HW_5LS187.6-1.exe | |
Description |
V4.0 HW Upgrade (5LS187.6-1) Revision information 5LS187.6-1 Version 1.3.0.0: ID: 442030 / Support ID: 0 POWERLINK V2 operatingmode: managing node An error is causing higher transfer times on the PCIbus that are resulting in POWERLINK and I/O cycle time violations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(17170), 1\7669b0.can(122), 1\7669b0.epl(67) Version 1.2.7.0: ID: 429220 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 429240 / Support ID: 400151182 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of theinput data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16914), 1\7669b0.can(122), 1\7669b0.epl(66) Version 1.2.6.0: ID: 391580 Possibly incorrect display of the Powerlink status LEDs Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16402), 1\7669b0.can(122), 1\7669b0.epl(64) Version 1.2.5.0: ID: 376441 / Support ID: 400120997 Module sporadically not recognized in APC910 when booting Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16401), 1\7669b0.can(122), 1\7669b0.epl(64) Version 1.2.3.0: ID: 332305 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 336710 POWERLINK V2 MN mode: It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337445 / Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(16143), 1\7669b0.can(122), 1\7669b0.epl(63) Version 1.2.2.0: ID: 294795 / Support ID: 400070288 Update problem by plc restart Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(15375), 1\7669b0.can(122), 1\7669b0.epl(60) Version 1.2.1.0: ID: 285945 POWERLINK V2 CN mode: Asynchronous packets lost when there is a large asynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 286025 POWERLINK V2: Large fluctuations of IEEE 1588 Nettime (used for safety logbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(15374), 1\7669b0.can(122), 1\7669b0.epl(60) Version 1.2.0.2: ID: 256805 / Support ID: 400057319 POWERLINK: In controlled node mode, the I/O mapping was not applied when the manager was restarted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 256915 POWERLINK: LinkOK data point added. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 256960 POWERLINK: The net time is not always transferred correctly to the application. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 257050 POWERLINK: Support for 100 Mbit full duplex in Ethernet operating mode. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 265695 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 265900 POWERLINK V2: If the the Ready-Flag was canceled on the network, the ModuleOK was not cleared. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265795 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with "Chaned Station" on thesame network Error correction: When an iCN is used in the same POWERLINKnetwork with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning is that the sync response frames that are used to measure the timing of the "Chained Station" are not recognized by the iCN. Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\7669_0.pci(14861), 1\7669b0.can(122), 1\7669b0.epl(58) Version 1.1.13.0: ID: 226710 / Support ID: 400041497 Problems starting CAN-FW corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13324), 1\7669b0.can(122), 1\7669b0.epl(52) Version 1.1.12.0: ID: 230840 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13323), 1\7669b0.can(122), 1\7669b0.epl(52) Version 1.1.11.0: ID: 229065 CAN transmitter blockade after cable un-/plugged corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13067), 1\7669b0.can(122), 1\7669b0.epl(51) Version 1.1.10.0: ID: 224445 CAN TransmitQueue Reset command corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13067), 1\7669b0.can(120), 1\7669b0.epl(51) Version 1.1.9.0: ID: 220435 POWERLINK V2: Boot behavior improved Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(13067), 1\7669b0.can(117), 1\7669b0.epl(51) Version 1.1.8.0: ID: 213030 CN mode: Various error corrections made. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(12043), 1\7669b0.can(117), 1\7669b0.epl(47) Version 1.1.7.0: ID: 206910 New POWERLINK firmware V45 and basis firmware V11 POWERLINK V2 CN mode: - Frequent MN failures result in CPU going into Service mode. - The PollResponse data from multiplexed stations are now updated in every POWERLINK cycle. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(11531), 1\7669b0.can(117), 1\7669b0.epl(45) Version 1.1.6.0: ID: 199525 New POWERLINK V1/V2 firmware V44 CN mode: Various error corrections made. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7669_0.pci(11274), 1\7669b0.can(117), 1\7669b0.epl(44) Version 1.1.5.1: ID: 191750 New POWERLINK V1/V2 Firmware V42and basis firmware V10 - Error correction for POWERLINK V2: After network disturbances, failed stations were left out of cyclic traffic. - Error correction POWERLINK V2 CN mode: Failure of a SoC resulted immediately in incorrect failure detection by manager. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware:1\7669_0.pci(10762), 1\7669b0.can(117), 1\7669b0.epl(42) Version 1.1.4.0: ID: 185600 New POWERLINK V1/V2 firmware V39 and basis firmware V9 - Error correction for POWERLINK V2: Certain configurations may cause multiplexed stations to fail. - Error correction for POWERLINK V2: An error while switching the alternating buffer caused old input data to be resent. (This error only occurred with upgrade 1.1.3.0.) - Error correction: In configurations with a large amount of I/O data, incorrect input data was sent. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9993), 1\7669b0.can(117), 1\7669b0.epl(39) Version 1.1.3.0: ID: 183640 New POWERLINK V1/V2 firmware V38 and basis firmware V8 - Error correction for POWERLINK V2: Parameter "CycleIdleTime" was not calculated correctly. - Error correction: ModbusTCP on POWERLINK interfaces was not working. - Improved stability for network disturbances. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9736), 1\7669b0.can(117), 1\7669b0.epl(38) Version 1.1.2.0: ID: 178025 New POWERLINK V1/V2 firmware V37 and base firmware V6 Error corrections: - POWERLINK V2 CN mode: Various error corrections made. - Asynchronous scheduler: The host has only sent an asynchronous frame in max. every second cycle. - POWERLILNK V2: Asynchronous frames can now be received with the Powerlinklibrary starting with channel >=0x20 (previously starting with 0xA0). Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9478), 1\7669b0.can(117), 1\7669b0.epl(37) Version 1.1.1.0: ID: 173335 New POWERLINK firmware V36 Error correction: - When using an I/O prescaler > 1, in certain circumstances the old input data for the station is provided to the application. - ISSI-RAMs are supported. Changes - POWERLINK V2: - The poll response from the manager is now sent at the beginning of the POWERLINK cycle. - From nowon, stations are addressed with poll requests starting in status "PreOperational 2". Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(9221), 1\7669b0.can(117), 1\7669b0.epl(36) Version 1.1.0.0: ID: 171125 Performance improvement - POWERLINK manager Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8964), 1\7669b0.can(117), 1\7669b0.epl(35) Version 1.0.6.0: ID: 167027 5LS187.6-1 doesn't works with Automation Runtime >= 2.92 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 167200 New base firmware V3 Collisions resulted in transmission of invalid frames. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8707), 1\7669b0.can(117), 1\7669b0.epl(34) Version 1.0.5.0: ID: 165815 New POWERLINK V1/V2 Firmware V34 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8706), 1\7669b0.can(117), 1\7669b0.epl(34) Version 1.0.4.0: ID: 165455 New POWERLINK V1/V2 Firmware V33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(8450), 1\7669b0.epl(33) Version 1.0.3.0: ID: 164770 New POWERLINK V1/V2 Firmware V31 - Optimizations for EPL V2 startup carried out. - Nettime IEEE 1588 for EPL V2 implemented. - From now on, the asynchronous scheduler will handle asynchronous requestsbased on their priority. Channel description changed: No Configurationdescription changed: No Firmware changed: No Firmware: 1\7669_0.pci(7938), 1\7669b0.epl(31) Version 1.0.1.0: ID: 160755 New Firmware V30 In "Controlled Node" mode, the following errors may occur: - With heavy asynchronous loads, asynchronous TX packets may be lost. - Collisions on the network can cause the station to stop receiving Ethernet packets. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7669_0.pci(7682), 1\7669b0.epl(30) |