DWL@DWL10000305619
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.4.0.0 | * | 06/11/2018 | 4 MB | EXE | AS3.0_HW_X20CS2770.exe | |
Description |
V3.0 HW Upgrade (X20CS2770) Revision information X20CS2770 Version 1.4.0.0: ID: 585570 CAN passive error In some rare cases the CAN controller in the BC detects erroneous bit errors in CAN frames if the incoming frame starts during a short period of time before the BC itself starts the transmission of a CAN frame. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 593255 Module documentation revised Data sheet V 3.26 Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(100) Version 1.3.5.0: ID: 525835 Module documentation revised Data sheet V3.24 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.3.4.0: ID: 493120 Module documentationrevised Data sheet V3.23 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.3.3.0: ID: 459910 Module documentation revised Datasheet V 3.22 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 463075 Syntaxerror in hwx corrected Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.3.2.0: ID: 440200 Corrected documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.3.1.2: ID: 427595 Documentation Correction Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.3.1.0: ID: 395055 / Support ID: 400123608 Adaption for Feldbus Designer Pro Customer specific offset values can be provided in Feldbus Designer Pro. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.3.0.5: ID: 368670 Correction of internal Rx/Tx registers for usage with function model "cyclic stream" "Extended error statusinformation" can be switched on, when function model "cyclic stream" is chosen. Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.3.0.4: ID: 332945 Optimization of MTU (cyclic stream) Both interfaces transport 13Byte per bus cycle. 8Byte user data(CAN), 4Byteoverhead (CAN), 1Byte overhead (Cyclicstream) Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.3.0.1: ID: 315540 Additional data point for IO mapping (cyclic stream) Data point "QuitCANIF1warning" is shown in IO-Mapping Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.3.0.0: ID: 290395 Support cyclic stream Additional function model "cyclic stream" implemented (AR J4.02) Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.2.4.1: ID: 272345 / Support ID: 400076453 Length check of I/O data in flatmode corrected Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.2.4.0: ID: 268695 / Support ID: 400055350 Enhancement length check of I/O block size during Build Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.2.3.0: ID: 221150 New configuration data point : BlockForwardDelay Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.2.2.0: ID: 188145 Error in Message FIFO and BC mode corrected Error in Message FIFO and BC mode corrected, new FWV12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.2.1.2: ID: 182955 Text corrections in HWC Text corrections in HWC Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(11) Version 1.2.1.1: ID: 182555 Enhancement mode SGC and correction of internal communication Enhancement mode SGC and correction of internal communication; new FW V11, upgrade 1.2.1.0 caused exception on some PC's Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(11) Version 1.2.1.0: ID: 175095 Enhancement mode SGC and correction of internal communication Enhancementmode SGC and correction of internal communication; new FW V11 Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(11) Version 1.2.0.0: ID: 169830 Enhancement flat stream function model and Buscontroller mode Enhancement flat stream function model and Buscontrollermode Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(10) Version 1.1.0.0: ID: 165540 New Firmware V3 and HWC V1.1.0.0 Support Streamer and Powerlink BC Supervision channel Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(3) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.3.5.0 | * | 07/06/2017 | 4 MB | EXE | AS3.0_HW_X20CS2770.exe | |
Description |
V3.0 HW Upgrade (X20CS2770) Revision information X20CS2770 Version 1.3.5.0: ID: 525835 Module documentation revised Data sheet V3.24 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.3.4.0: ID: 493120 Module documentation revised Data sheet V3.23 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.3.3.0: ID: 459910 Module documentation revised Datasheet V 3.22 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 463075 Syntaxerror in hwx corrected Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.3.2.0: ID: 440200 Corrected documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.3.1.2: ID: 427595 Documentation Correction Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.3.1.0: ID: 395055 / Support ID: 400123608 Adaption for Feldbus Designer Pro Customer specific offset values can be provided in Feldbus Designer Pro. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.3.0.5: ID: 368670 Correction of internal Rx/Tx registers for usage with function model "cyclic stream" "Extended error status information" can be switched on, when function model"cyclic stream" is chosen. Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.3.0.4: ID: 332945 Optimization of MTU (cyclic stream) Both interfaces transport 13Byte per bus cycle. 8Byte user data (CAN), 4Byte overhead (CAN), 1Byte overhead (Cyclicstream) Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.3.0.1: ID: 315540 Additional data point for IO mapping (cyclic stream) Data point "QuitCANIF1warning" is shown in IO-Mapping Channeldescription changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.3.0.0: ID: 290395 Support cyclic stream Additional function model "cyclic stream" implemented (AR J4.02) Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.2.4.1: ID: 272345 / Support ID: 400076453 Length check of I/O data in flat mode corrected Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.2.4.0: ID: 268695 / Support ID: 400055350 Enhancement length check of I/O block size during Build Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.2.3.0: ID: 221150 New configuration data point : BlockForwardDelay Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.2.2.0: ID: 188145 Error in Message FIFOand BC mode corrected Error in Message FIFO and BC mode corrected, new FW V12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(12) Version 1.2.1.2: ID: 182955 Text corrections in HWC Text corrections in HWC Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(11) Version 1.2.1.1: ID: 182555 Enhancement mode SGC and correction of internal communication Enhancement mode SGC and correction of internal communication; new FW V11, upgrade 1.2.1.0caused exception on some PC's Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(11) Version 1.2.1.0: ID: 175095 Enhancement mode SGC and correction of internal communication Enhancement mode SGC and correction of internal communication; new FW V11 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(11) Version 1.2.0.0: ID: 169830 Enhancement flat stream function model and Buscontroller mode Enhancement flat stream function model and Buscontroller mode Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(10) Version 1.1.0.0: ID: 165540 New Firmware V3 and HWCV1.1.0.0 Support Streamer and Powerlink BC Supervision channel Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\40969_1.fw(2), 2\40969_1.fw(3) |