DWL@DWL10000344418
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.4.3.0 | * | 12/06/2017 | 2 MB | EXE | AS3.0_HW_X20CP1584.exe | |
Description |
V3.0 HW Upgrade (X20CP1584) Revision information X20CP1584 Version 1.4.3.0: ID: 538525 / Support ID: 400204420 POWERLINK V2: noasynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\50032_0.pci(17), 1\50032a0.epl(131) Version 1.4.0.0: ID: 497865 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed:No ID: 520790 Module documentation revised Data sheet V 1.37 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 521655 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware:1\50032_0.pci(17), 1\50032a0.epl(129) Version 1.3.2.0: ID: 490210 Additional info data points FirmwareVersion and HardwareVariant Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\50032_0.pci(17), 1\50032a0.epl(129) Version 1.3.0.0: ID: 462585 IP packets with multicast addresses not received by POWERLINK interface (problem only occurs with Automation Runtime versions <A4.23) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462680 Update online help Channel description changed: No Configurationdescription changed: No Firmware changed: No ID: 462755 / Support ID: 400134699 Reduced X2X susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462845 / Support ID: 400164226 Corrected DRAM sizes in documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\50032_0.pci(17), 1\50032a0.epl(129) Version 1.2.0.0: ID: 443680 / Support ID: 400154848 IP packets with multicast addresses not received by thePOWERLINK interface Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 444260 Documentation changed Channel description changed: No Configuration description changed: No Firmware changed: No ID: 445110 Documentation changed Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\50032_0.pci(15), 1\50032a0.epl(128) Version 1.1.0.0: ID: 417200 Enhancement ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 417275 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 417340 Documentation: enhancements and corrections Channel description changed: No Configuration description changed: No Firmware changed: No ID: 417465 Optimized EMC characteristics for GL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 419470 / Support ID: 400149136 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 423965 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 424070 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controllednode sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\50032_0.pci(15), 1\50032a0.epl(127) Version 1.0.3.1: ID: 359005 POWERLINK MN mode: If "Multiplexing prescale" >= 9, then the input data of the multiplexed stations that were configured in the last "network cycle" were not transferred incertain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 359230 / Support ID: 400113446 POWERLINK V2 MN mode: Asynchronous connection losses may occur as a result of high asynchronous loads on the POWERLINK networkand high loads on the CPU. This could maintain you to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360210 POWERLINK V1 MN mode Error correction: Cyclic input data and net time toggle between the last two received values when CNs drop out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360265 / Support ID: - POWERLINK V1 MN mode: "Nettime SoC" is not increased. Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.0.2.0: ID: 332350 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINKV1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication"to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 336725 POWERLINK V2 MN mode: It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337490 / Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting that causedthe interface to fail.^ Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\50032_0.pci(11), 1\50032a0.epl(120) Version 1.0.1.4: ID: 307265 Enhancement English online-help and error corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\50032_0.pci(11), 1\50032a0.epl(117) Version 1.0.1.3: ID: 285190 Support X20CP1584 First Version Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\50032_0.pci(11), 1\50032a0.epl(117) |