DWL@DWL10000304725
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
2.11.0.0 | * | 31/01/2020 | 2 Mo | EXE | AS3.0_HW_X20cBC8083.exe | |
Description |
V3.0 HW Upgrade (X20cBC8083) Revision information X20cBC8083 Version 2.11.0.0: ID: 664350 DNA: Hub of PLK BC active until firstIDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 664390 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665770 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665850 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666205 Module documentation revised Data sheet V2.38 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57880_4.fw(430), 1\57880_5.fw(430), 1\57880_6.fw(430), 1\57880_7.fw(430) Version 2.10.0.0: ID: 647955 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(428), 1\57880_5.fw(428), 1\57880_6.fw(428), 1\57880_7.fw(428) Version 2.9.0.0: ID: 628945 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629025 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629090 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629175 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(427), 1\57880_5.fw(427), 1\57880_6.fw(427) Version 2.8.0.0: ID: 619160 / Support ID: 400257683 DNA: PLK hub forwardingfor the next node not enabled in rare cases Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 619195 / Support ID: 400262159 Outputs of I/O modules behind thebus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(426), 1\57880_5.fw(426), 1\57880_6.fw(426) Version 2.7.0.0: ID: 586735 / Support ID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(424), 1\57880_5.fw(424), 1\57880_6.fw(424) Version 2.6.0.0: ID: 574945 Optimizationof boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(423), 1\57880_5.fw(423), 1\57880_6.fw(423) Version 2.5.6.0: ID: 565110 Optimization the boot up for hardwarevariant 5 Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 1\57880_4.fw(422), 1\57880_5.fw(422) Version 2.5.5.0: ID: 551135 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(421), 1\57880_5.fw(421) Version 2.5.4.0: ID: 540330 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(419) Version 2.5.3.0: ID: 523500 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(417) Version 2.5.2.0: ID: 493900 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(415) Version 2.5.0.0: ID: 468120 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468125 / Support ID: 400177243 X2X FWupdate of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468130 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468555 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57880_4.fw(413) Version 1.3.0.0: ID: 460120 / SupportID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460240 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 466685 Module documentation revised Datasheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57880_4.fw(411) Version 1.2.1.0: ID: 449605 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(401) Version 1.2.0.0: ID: 439115 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 439220 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(400) Version 1.1.0.0: ID: 404505 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel descriptionchanged: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(300) Version 1.0.0.1: ID: 343255 Support X20cBC8083 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57880_4.fw(210) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.10.0.0 | * | 10/07/2019 | 2 Mo | EXE | AS3.0_HW_X20cBC8083.exe | |
Description |
V3.0 HW Upgrade (X20cBC8083) Revision information X20cBC8083 Version 2.10.0.0: ID: 647955 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(428), 1\57880_5.fw(428), 1\57880_6.fw(428), 1\57880_7.fw(428) Version 2.9.0.0: ID: 628945 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629025 Ring redundancy: Cannot address the CN that closes thering Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629090 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629175 Shortened preamble of Ethernet frame leading to incorrectly detectedCRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(427), 1\57880_5.fw(427), 1\57880_6.fw(427) Version 2.8.0.0: ID: 619160 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619195 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(426), 1\57880_5.fw(426), 1\57880_6.fw(426) Version 2.7.0.0: ID: 586735 / Support ID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(424), 1\57880_5.fw(424), 1\57880_6.fw(424) Version 2.6.0.0: ID: 574945 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(423), 1\57880_5.fw(423), 1\57880_6.fw(423) Version 2.5.6.0: ID: 565110 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\57880_4.fw(422), 1\57880_5.fw(422) Version 2.5.5.0: ID: 551135 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(421), 1\57880_5.fw(421) Version 2.5.4.0: ID: 540330 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(419) Version 2.5.3.0: ID: 523500 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(417) Version 2.5.2.0: ID: 493900 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(415) Version 2.5.0.0: ID: 468120 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468125 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468130 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468555 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57880_4.fw(413) Version 1.3.0.0: ID: 460120 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460240 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 466685 Module documentation revised Data sheet V 2.32 Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57880_4.fw(411) Version 1.2.1.0: ID: 449605 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(401) Version 1.2.0.0: ID: 439115 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 439220 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 1\57880_4.fw(400) Version 1.1.0.0: ID: 404505 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problemalso occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(300) Version 1.0.0.1: ID: 343255 Support X20cBC8083 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57880_4.fw(210) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.9.0.0 | * | 01/03/2019 | 2 Mo | EXE | AS3.0_HW_X20cBC8083.exe | |
Description |
V3.0 HW Upgrade (X20cBC8083) Revision information X20cBC8083 Version 2.9.0.0: ID: 628945 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629025 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629090 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629175 Shortened preamble of Ethernet frame leading toincorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(427), 1\57880_5.fw(427), 1\57880_6.fw(427) Version 2.8.0.0: ID: 619160 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619195 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(426), 1\57880_5.fw(426), 1\57880_6.fw(426) Version 2.7.0.0: ID: 586735 / Support ID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(424), 1\57880_5.fw(424), 1\57880_6.fw(424) Version 2.6.0.0: ID: 574945 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(423), 1\57880_5.fw(423), 1\57880_6.fw(423) Version 2.5.6.0: ID: 565110 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(422), 1\57880_5.fw(422) Version 2.5.5.0: ID: 551135 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(421), 1\57880_5.fw(421) Version 2.5.4.0: ID: 540330 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(419) Version 2.5.3.0: ID: 523500 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is notalways established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(417) Version 2.5.2.0: ID: 493900 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(415) Version 2.5.0.0: ID: 468120 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468125 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468130 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468555 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57880_4.fw(413) Version 1.3.0.0: ID: 460120 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460240 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 466685 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57880_4.fw(411) Version 1.2.1.0: ID: 449605 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(401) Version 1.2.0.0: ID: 439115 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439220 / Support ID: 400128436 I/Omodules behind POWERLINK bus controllers no longer achieving Operationalmodeafter multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(400) Version 1.1.0.0: ID: 404505 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(300) Version 1.0.0.1: ID: 343255 Support X20cBC8083 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57880_4.fw(210) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.8.0.0 | * | 05/12/2018 | 2 Mo | EXE | AS3.0_HW_X20cBC8083.exe | |
Description |
V3.0 HW Upgrade (X20cBC8083) Revision information X20cBC8083 Version 2.8.0.0: ID: 619160 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 619195 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(426), 1\57880_5.fw(426), 1\57880_6.fw(426) Version 2.7.0.0: ID: 586735 / SupportID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(424), 1\57880_5.fw(424), 1\57880_6.fw(424) Version 2.6.0.0: ID: 574945 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(423), 1\57880_5.fw(423), 1\57880_6.fw(423) Version 2.5.6.0: ID: 565110 Optimization the boot up forhardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(422), 1\57880_5.fw(422) Version 2.5.5.0: ID: 551135 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(421), 1\57880_5.fw(421) Version 2.5.4.0: ID: 540330 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(419) Version 2.5.3.0: ID: 523500 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(417) Version 2.5.2.0: ID: 493900 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(415) Version 2.5.0.0: ID: 468120 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468125 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468130 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468555 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57880_4.fw(413) Version 1.3.0.0: ID: 460120 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460240 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 466685 Module documentation revised Data sheet V 2.32 Channel description changed: No Configurationdescription changed: No Firmware changed: No Firmware: 1\57880_4.fw(411) Version 1.2.1.0: ID: 449605 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(401) Version 1.2.0.0: ID: 439115 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 439220 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(400) Version 1.1.0.0: ID: 404505 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshakebetween Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLinkis supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(300) Version 1.0.0.1: ID: 343255 Support X20cBC8083 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57880_4.fw(210) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.7.0.0 | * | 17/04/2018 | 2 Mo | EXE | AS3.0_HW_X20cBC8083.exe | |
Description |
V3.0 HW Upgrade (X20cBC8083) Revision information X20cBC8083 Version 2.7.0.0: ID: 586735 / Support ID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(424), 1\57880_5.fw(424), 1\57880_6.fw(424) Version 2.6.0.0: ID: 574945 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(423), 1\57880_5.fw(423), 1\57880_6.fw(423) Version 2.5.6.0: ID: 565110 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(422), 1\57880_5.fw(422) Version 2.5.5.0: ID: 551135 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(421), 1\57880_5.fw(421) Version 2.5.4.0: ID: 540330 / Support ID: 400202320 BC sporadicallynot going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\57880_4.fw(419) Version 2.5.3.0: ID: 523500 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(417) Version 2.5.2.0: ID: 493900 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(415) Version 2.5.0.0: ID: 468120 /Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468125 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468130 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468555 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57880_4.fw(413) Version 1.3.0.0: ID: 460120 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460240/ Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal"bei CPU PowerCycle wenn SLXhinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 466685 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57880_4.fw(411) Version 1.2.1.0: ID: 449605 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(401) Version 1.2.0.0: ID: 439115 / SupportID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439220 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(400) Version 1.1.0.0: ID: 404505 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(300) Version 1.0.0.1: ID: 343255 Support X20cBC8083 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57880_4.fw(210) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.6.0.0 | * | 02/02/2018 | 2 Mo | EXE | AS3.0_HW_X20cBC8083.exe | |
Description |
V3.0 HW Upgrade (X20cBC8083) Revision information X20cBC8083 Version 2.6.0.0: ID: 574945 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(423), 1\57880_5.fw(423), 1\57880_6.fw(423) Version 2.5.6.0: ID: 565110 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\57880_4.fw(422), 1\57880_5.fw(422) Version 2.5.5.0: ID: 551135 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(421), 1\57880_5.fw(421) Version 2.5.4.0: ID: 540330 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(419) Version 2.5.3.0: ID: 523500 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(417) Version 2.5.2.0: ID: 493900 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(415) Version 2.5.0.0: ID: 468120 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468125 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468130 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468555 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57880_4.fw(413) Version 1.3.0.0: ID: 460120 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460240 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 466685 Module documentation revised Data sheet V 2.32 Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57880_4.fw(411) Version 1.2.1.0: ID: 449605 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(401) Version 1.2.0.0: ID: 439115 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 439220 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 1\57880_4.fw(400) Version 1.1.0.0: ID: 404505 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problemalso occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\57880_4.fw(300) Version 1.0.0.1: ID: 343255 Support X20cBC8083 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57880_4.fw(210) |