DWL@DWL10000241102

Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.0.1.1 * 28/06/2013 472 KB EXE AS3.0_HW_5PP5IF.FX2X-00.exe
Description V3.0 HW Upgrade (5PP5IF.FX2X-00)

Revision information 5PP5IF.FX2X-00

Version 2.0.1.1:

ID: 340505
APROL support added for AS4.x
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\46297_0.pci(3)

Version 2.0.1.0:

ID: 278380
Increasing the available storage area for remanent data + Important information!
In conjunction with this upgrade - fromthe Automation Runtime version B4.01on a storage area of 256kB can be used to save remanent datas in the SRAM.

Attention, important information: If this upgrade will be installed in conjunction with Automation Runtime >= A4.01,
it is absolutely necassery because of a conceptual change in the hardware representation,
that all of the components of used PP500/APC5xxhave a version >= V2.0.0.0,
otherwise it may be compatibility problems with the used Automation Runtime.
Affected are the following components: 5PP5##* (system units), 5PP5CP* (CPUboards), 5PP5IF* (interface boards), 5PP5IO* (I / O boards).
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\46297_0.pci(3)

Version 1.0.1.0:

ID: 271780
Problem with UserRAM
The problem, that the Power Panel 500 reboots cyclic when using the UserRAMarea, has been fixed.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\46297_0.pci(3)

Version 1.0.0.1:

ID: 266260
Problem with the SRAM
Problem with SRAM is solved.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\46297_0.pci(2)

Version 1.0.0.0:

ID: 265945
Support for 5PPIF.FX2X-00
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\46297_0.pci(1)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.0.1.0 * 01/03/2012 472 KB EXE AS3.0_HW_5PP5IF.FX2X-00.exe
Description V3.0 HW Upgrade (5PP5IF.FX2X-00)

Revision information 5PP5IF.FX2X-00

Version 2.0.1.0:

ID: 278380
Increasing the available storage area for remanent data + Important information!
In conjunction with this upgrade - from the Automation Runtime version B4.01 on a storage area of 256kB can be used to save remanent datas in the SRAM.

Attention, important information: If this upgrade will be installed in conjunction with Automation Runtime >= A4.01,
it is absolutely necassery because of a conceptual change in the hardware representation,
that all of the components of used PP500/APC5xx have a version >= V2.0.0.0,
otherwise it may be compatibility problems with the used Automation Runtime.
Affected are the following components: 5PP5##* (system units), 5PP5CP* (CPU boards), 5PP5IF* (interface boards),5PP5IO* (I / O boards).
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\46297_0.pci(3)

Version 1.0.1.0:

ID: 271780
Problem with UserRAM
The problem, that the Power Panel 500 reboots cyclic when using the UserRAMarea, has been fixed.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\46297_0.pci(3)

Version 1.0.0.1:

ID: 266260
Problem with the SRAM
Problem with SRAM is solved.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\46297_0.pci(2)

Version 1.0.0.0:

ID: 265945
Support for 5PPIF.FX2X-00
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\46297_0.pci(1)
Loading