DWL@DWL10000074582

Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.0.0.0 * 31/03/2016 1 MB EXE AS2.6_HW_80SD100XS.C0XX-01.exe
Description V2.7 HW Upgrade (80SD100XS.C0XX-01)

Revision information 80SD100XS.C0XX-01

Version 2.0.0.0:

ID: 472780
Error correction in order to guard motor outputs against short to ground
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42414_1.fw(106), 1\42414_2.fw(106), 1\42414_3.fw(106), 1\42414_4.fw(106), 1\42414_5.fw(106)

Version 1.9.0.0:

ID: 439735
Drive is running in the function model motion in full-step mode
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42414_1.fw(104), 1\42414_2.fw(104), 1\42414_3.fw(104), 1\42414_4.fw(104)

Version 1.8.0.0:

ID: 400850
Cycle time of MPGen edjustable
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 400905
Function model Ramp: new mode
Mode -120: Set home position
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 401005
Corrected a problem in HWX file
Channel description changed: No
Configuration description changed:No
Firmware changed: No

ID: 438080
Support for HW-Variant 4
Channel description changed: No
Configuration description changed:No
Firmware changed: Yes

ID: 438090
Corrected HWC entry
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42414_1.fw(101), 1\42414_2.fw(101),1\42414_3.fw(101), 1\42414_4.fw(101)

Version 1.6.4.0:

ID: 319030
Module bootup timeout configured
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 320795
Accelerated firmware update.
Allows reliable firmware update behind CANIO bus controllers.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42414_1.fw(14), 1\42414_2.fw(14), 1\42414_3.fw(14)

Version 1.6.3.0:

ID: 301450
Support for HW-Variant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42414_1.fw(13), 1\42414_2.fw(13), 1\42414_3.fw(13)

Version 1.6.2.0:

ID: 296355 / Support ID: 400087355
80SD100XS.C0XX-01: Erroneous Detection of Short Circuit between Motor-Phaseand Ground
Due to a Firmware-Error the activation of the Controller could be blocked under certain circumstances because of a wrongly assumed Short Circuit to Ground
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42414_1.fw(13), 1\42414_2.fw(13)

Version 1.6.1.0:

ID: 290020 / Support ID: 400082483
In rare cases ACOPOSmicro generated an erroneous status indication (UZKStatus = not OK).
Also high motor currents in conjunction with tolerances of electronic components could lead to module internal disturbances which in consequencecould generate error messages.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42414_1.fw(12), 1\42414_2.fw(12)

Version 1.6.0.0:

ID: 281905 /Support ID: 400081681
SG3 support
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\42414_1.fw(11), 1\42414_2.fw(11)

Version 1.5.1.0:

ID: 272475 / Support ID: 400049998
Module in undefined state, if no trigger happens in mode -121 (Remaining distance mode)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 272480 / Support ID: 400051695
The ACOPOSMicro doesn't switch in switched on with a customer motor at rampmode
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 272485
Ramp mode: Wrong configuratin for referencing speed is possible
Channel description changed: No
Configuration descriptionchanged: Yes
Firmware changed: No
Firmware: 1\42414_1.fw(11), 1\42414_2.fw(11)

Version 1.4.1.2:

ID: 245885
Customer-specificexpansion of hardware description file
This upgrade has no impact on theAutomation Studio and the standard versionof the FieldbusDESIGNER
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42414_1.fw(10), 1\42414_2.fw(10)

Version 1.4.1.1:

ID: 243385
Customer-specific expansion of hardwaredescription file
This upgrade has no impact on the Automation Studio andthe standard versionof the FieldbusDESIGNER
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42414_1.fw(10), 1\42414_2.fw(10)

Version 1.1.0.0:

ID: 205090
Support for the module 80SD100XS.C0XX-01 behind a buscontroller
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\42414_1.fw(5), 1\42414_2.fw(5)