DWL@DWL10000062754

Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.1.0.0 * 29/03/2016 1 Mo EXE AS2.6_HW_80SD100XD.C0XX-01.exe
Description V2.7 HW Upgrade (80SD100XD.C0XX-01)

Revision information 80SD100XD.C0XX-01

Version 2.1.0.0:

ID: 472295
Error correction in order to guard motor outputs against short to ground
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42148_1.fw(106), 1\42148_2.fw(106), 1\42148_3.fw(106), 1\42148_4.fw(106), 1\42148_5.fw(106)

Version 2.0.0.1:

ID: 400955
Corrected a problem in HWX file
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 439730
Drive is running in the function model motion in full-step mode
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42148_1.fw(104), 1\42148_2.fw(104), 1\42148_3.fw(104), 1\42148_4.fw(104)

Version 1.9.0.0:

ID: 382405 / Support ID: 400133806
Corrected HWC entry
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 400810
Cycle time of MPGen edjustable
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 400870
Function model Ramp: new mode
Mode -120: Set home position
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 400955
Corrected a problem in HWX file
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 437825
Support for HW-Variant 4
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42148_1.fw(101), 1\42148_2.fw(101), 1\42148_3.fw(101), 1\42148_4.fw(101)

Version 1.7.3.0:

ID: 319010
Module bootup timeout configured
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 319035
Accelerated firmware update.
Allows reliable firmware update behind CANIO bus controllers.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42148_1.fw(20), 1\42148_2.fw(20), 1\42148_3.fw(20)

Version 1.7.2.0:

ID: 296350 / Support ID: 400087355
80SD100XD.C0XX-01: Erroneous Detection of Short Circuit between Motor-Phaseand Ground
Due to a Firmware-Error the activation of the Controller could be blocked under certain circumstances because of a wrongly assumed Short Circuit to Ground
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 298085
Support for HW-Variant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42148_1.fw(19),1\42148_2.fw(19), 1\42148_3.fw(19)

Version 1.7.1.0:

ID: 290015 / Support ID: 400082483
In rare cases ACOPOSmicro generated an erroneous status indication (UZKStatus = not OK).
Also high motor currents in conjunction with tolerances of electronic components could lead to module internal disturbances which in consequence could generate error messages.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42148_1.fw(18), 1\42148_2.fw(18)

Version 1.7.0.0:

ID: 280535 / Support ID: 400081681
SG3 support
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\42148_1.fw(17), 1\42148_2.fw(17)

Version 1.6.1.0:

ID: 272405 / Support ID: 400049998
Module in undefined state, if no trigger happens in mode -121 (Remaining distance mode)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 272410 / Support ID: 400051695
The ACOPOSMicro doesn't switch in switched on with a customer motor at rampmode
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 272415
Ramp mode: Wrong configuratin for referencing speed is possible
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\42148_1.fw(17), 1\42148_2.fw(17)

Version 1.5.1.1:

ID: 243235
Customer-specific expansion of hardware description file
This upgrade has no impact on the Automation Studio and the standard versionof the FieldbusDESIGNER
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42148_1.fw(16), 1\42148_2.fw(16)

Version 1.5.0.0:

ID: 227695
Fully support for SDC
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\42148_1.fw(15), 1\42148_2.fw(15)

Version 1.4.1.0:

ID: 219220 / Support ID:400033889
Error when inserting the module on SGC CPU
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\42148_1.fw(13), 1\42148_2.fw(13)

Version 1.1.3.0:

ID: 199685 / Support ID: 400019148
Brake output will be reset when X2X bus is not present
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42148_1.fw(8), 1\42148_2.fw(8)

Version 1.1.2.0:

ID: 182205
Error resetting works now without problems
Channel description changed:No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42148_1.fw(7), 1\42148_2.fw(7)

Version 1.1.1.0:

ID: 195015 / Support ID: 400015253
From the version 1.1.1.0 the Ramp-functionmodell works on SGC CPU's
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\42148_1.fw(6), 1\42148_2.fw(6)

Version 1.1.0.0:

ID: 193010
New function model: ramp function modell
Extension of firmware and HWC-File: Support of ramp function model for operation of the module behind bus couplers and SGC-CPUs.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\42148_1.fw(6), 1\42148_2.fw(6)
Loading
Retour à la liste

Veuillez sélectionner un pays et une langue