DWL@DWL10000053709
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.03 | * | DOS | 08/07/2009 | 250 Ko | ZIP | PPC300_BIOS_Upgrade_Disk_V0103.zip |
Description |
BIOS Upgrade ------------------------------------------------------------------ UPDATE PROCEDURE ------------------------------------------------------------------ 1. Copy all files to a bootable disk. (Alternatively, a bootable Compact Flash or a USB stick can be used. Detailed information can be found in the Panel PC 310 User Manual.) 2. Insert the disk in a (USB) floppy drive connected to the Panel PC 310 and re-boot the device. 3. A boot menu with following options is shown after booting: 1. Update BIOS => default after 5 sec The BIOS will be updated automatically. *********************************************** Write down your BIOS settings before upgrading! *********************************************** After a BIOS update the BIOS uses automatically the CMOS default settings. If you have changed settings in the BIOS Setup you must change these settings again after update! *************************** Do not abort a BIOS update! *************************** Otherwise the Panel PC 310 cannot be rebooted afterwards and must be sent to B&R for repair. Retry the aborted update process WITHOUT rebooting the Panel PC 310, for example by directly calling batch file UPDBIOS.BAT. 2. Save BIOS (into directory SAVED) The BIOS will be saved automatically in the directory SAVED. *********************************************************** There must be about 256 kbytes free space left on the disk. *********************************************************** 3. Exit Exit to the Shell (MS-DOS). 4. Select the desired action. 5. Remove disk and reboot device (after successful update only!). ---------------------------------------------------------------- Version 1.03 / 2009-06-22 ---------------------------------------------------------------- Contents: 0023#0.bio 1.06 NEW LIESMICH.TXT 1.03 NEW README.TXT 1.03 NEW LXFLASH.EXE 3.02 AUTOEXEC.BAT CONFIG.SYS SavBIOS.BAT UPDBIOS.BAT Fixes: - BIOS: Bugfix regarding network problems on PPC310 devices: At high network load and BIOS versions smaller V1.06 it can theoretically be possible, that on PPC310 devices the network connection is lost. At the moment we have no known failure or reported problem. |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.02 | * | DOS | 10/09/2008 | 250 Ko | ZIP | PPC300_BIOS_Upgrade_Disk_V0102.zip |
Description |
BIOS Upgrade ----------------------------------------------------------------UPDATE PROCEDURE ---------------------------------------------------------------- 1. Copy all files to a bootable disk. 2. Insert the disk in a (USB) floppy drive connected to the Panel PC 310 and re-boot the device. 3. A boot menu with following options is shown after booting: *1. Update BIOS => default after 5 sec The BIOS will be updated automatically. *********************************************** Write down your BIOS settings before upgrading! *********************************************** After a BIOS update the BIOS uses automatically the CMOS default settings. If you have changed settings in the BIOS Setup you must change these settings again after update! *************************** Do not abort a BIOS update! *************************** Otherwise the Panel PC 310 cannot be rebooted afterwards and must be sent to B&R for repair. Retry the aborted update process WITHOUT rebooting the Panel PC 310, for example by directly calling batch file UPDBIOS.BAT. *2. Save BIOS (into directory SAVED) The BIOS will be saved automatically in the directory SAVED. *********************************************************** There must be about 256 kbytes free space left on the disk. *********************************************************** *3. Exit Exit to the Shell (MS-DOS). 4. Select the desired action. 5. Remove disk and reboot device (after successful update only!). ---------------------------------------------------------------- Version 1.02 / 2008-09-09 ---------------------------------------------------------------- Contents: 0023#0.bio 1.05 NEW LIESMICH.TXT 1.02 NEW README.TXT 1.02 NEW LXFLASH.EXE 3.02 NEW AUTOEXEC.BAT CONFIG.SYS SavBIOS.BAT UPDBIOS.BAT Fixes: - BIOS Setup: - Incorrect assignment of following settings for the serial COM ports Setup Allocation 3E8/IRQ4 -> 2E8/IRQ4 2E8/IRQ4 -> 2F8/IRQ3 3E8/IRQ12-> 2E8/IRQ12 - Problem with "Wheel Mouse Optical USB" from Microsoft fixed. Sporadically this USB mouse was not detected during bootup. Changes: - BIOS: Facilitating the entry into the BIOS setup pages, waiting time for [DEL] entries increased to 500ms. - BIOS: Optimizations for detecting several bootable USB devices in combination with USB Media Drive (timeouts increased). - BIOS: If the new BIOS detects differences in the CMOS structure between former and new BIOS version, the BIOS will automatically load the BIOS Setup defaults. - LXFLASH.EXE: Newest version. |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.01 | * | DOS | 18/09/2007 | 249 Ko | ZIP | PPC300_BIOS_Upgrade_Disk_V0101.zip |
Description |
BIOS Upgrade ----------------------------------------------------------------UPDATE PROCEDURE ---------------------------------------------------------------- 1. Copy all files to a bootable disk. 2. Insert the disk in a (USB) floppy drive connected to the Panel PC 310 and re-boot the device. 3. A boot menu with following options is shown after booting: 1. Update BIOS => default after 5 sec The BIOS will be updated automatically. *********************************************** Write down your BIOS settings before upgrading! *********************************************** After a BIOS update the BIOS uses automatically the CMOS default settings. If you have changed settings in the BIOS Setup you must change these settings again after update! *************************** Do not abort a BIOS update! *************************** Otherwise the Panel PC 310 cannot be rebooted afterwards and must be sent to B&R for repair. Retry the aborted update process WITHOUT rebooting the Panel PC 310, for example by directly calling batch file UPDBIOS.BAT. 2. Save BIOS (into directory SAVED) The BIOS will be saved automatically in the directory SAVED. *********************************************************** There must be about 256 kbytes free space left on the disk. *********************************************************** 3. Exit Exit to the Shell (MS-DOS). 4. Select the desired action. 5. Remove disk and reboot device (after successful update only!). ----------------------------------------------------------------Version 1.01 / 2007-07-12 ---------------------------------------------------------------- Contents: 0023#0.bio 1.03 NEW AUTOEXEC.BAT CONFIG.SYS LIESMICH.TXT NEW LXFLASH.EXE README.TXT NEW SavBIOS.BAT UPDBIOS.BAT Fixes: - Only MSDOS: Fixed the USB keyboard emulation for the right Ctrl and ALT keys. Fixed fail ALT-GR emulation with Keyb GR (16 bit MSDOS driver). |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.00 | * | DOS | 19/06/2007 | 248 Ko | ZIP | PPC300_BIOS_Upgrade_Disk_v0100.zip |
Description |
BIOS Upgrade ----------------------------------------------------------------UPDATE PROCEDURE ---------------------------------------------------------------- 1. Copy all files to a bootable disk. 2. Insert the disk in a (USB) floppy drive connected to the Panel PC 310 and re-boot the device. 3. A boot menu with following options is shown after booting: 1. Update BIOS => default after 5 sec The BIOS will be updated automatically. *********************************************** Write down your BIOS settings before upgrading! *********************************************** After a BIOS update the BIOS uses automatically the CMOS default settings. If you have changed settings in the BIOS Setup you must change these settings again after update! *************************** Do not abort a BIOS update! *************************** Otherwise the Panel PC 310 cannot be rebooted afterwards and must be sent to B&R for repair. Retry the aborted update process WITHOUT rebooting the Panel PC 310, for example by directly calling batch file UPDBIOS.BAT. 2. Save BIOS (into directory SAVED) The BIOS will be saved automatically in the directory SAVED. *********************************************************** There must be about 256 kbytes free space left on the disk. *********************************************************** 3. Exit Exit to the Shell (MS-DOS). 4. Select the desired action. 5. Remove disk and reboot device (after successful update only!). ---------------------------------------------------------------- Version 1.00 / 2007-03-23 ---------------------------------------------------------------- Contents: 0023#0.bio 1.02 NEW AUTOEXEC.BAT CONFIG.SYS LIESMICH.TXT NEW LXFLASH.EXE 3.00 NEW README.TXT NEW SavBIOS.BAT UPDBIOS.BAT |