DWL@DWL10000791404
| 版本 | 语言 | 操作系统 | 日期 | 尺寸 | 类型 | 下载 |
|---|---|---|---|---|---|---|
| 3.0.2.0 | * | 12/15/2025 | 477 KB | EXE | AS6_HW_X20SO6300.exe | |
| 描述 |
V6.0 HW Upgrade (X20SO6300) Revision information X20SO6300 Version 3.0.2.0: ID: FUVI-12000 Improved bootup behavior Fixed stability issues; faster bootup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\56708_1.fw(652) Version 3.0.0.0: ID: FUVI-11178 Control of the outputs reworked Control of the outputs reworked Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: FUVI-11177 New data sheet V3.0.0 New data sheet V3.0.0 Channel description changed: No Configuration description changed: No Firmware changed: No ID: FUVI-11176 First official release for Safety+ First official release for Safety+ Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56708_1.fw(650) Version 2.3.0.1: ID: 783540 Configuration for Power Calculation available The Configuration for Power Calculation is now available in Automation Studio Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\56708_1.fw(573) Version 2.3.0.0: ID: 715260 Failsafe at every boot It could happen underrare conditions that the module is stuck in failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data" Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 726625 The power calculation of the modules is supported The data for the power calculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 727170 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56708_1.fw(573) Version 2.2.1.0: ID: 706355 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 706425 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56708_1.fw(572) Version 2.2.0.1: ID: 688750 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 688885 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 688945 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 688960 Improvement of the feedback diagnosis. Improvement of the feedback diagnosis of the output. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\56708_1.fw(571) Version 2.1.0.0: ID: 644165 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\56708_1.fw(570) Version 1.10.10.0: ID: 622780 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(331) Version 1.10.9.1: ID: 643150 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300),6\56708_1.fw(330) Version 1.10.9.0: ID: 618270 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(330) Version 1.10.1.1: ID: 422790 Correction for FBK_Status_1 Correction for FBK_Status_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 532525 Improve the description section in the OSDD files Improve the description section in the OSDD files Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 532690 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 552490 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: Yes Configuration description changed: No Firmware changed:Yes ID: 552520 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(325) Version 1.10.0.6: ID: 532680 Addblackout mode Add blackout mode Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 532685 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(320) Version 1.10.0.2: ID: 507370 Added information about internal cycletime Added information about internal cycletime Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(320) Version 1.10.0.1: ID: 473225 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 473235 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(320) Version 1.9.0.1: ID: 413905 SafeModuleID >300 Now it is possibleto set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414075 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414260 parameter max. Switching Frequency removed Parameter max. Switching Frequency has no meaning any more. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 414400 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300) Version 1.6.0.9: ID: 393950 first officialrelease first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 3\56708_1.fw(281) |
|||||
| 版本 | 语言 | 操作系统 | 日期 | 尺寸 | 类型 | 下载 |
| 3.0.1.0 | * | 10/09/2025 | 776 KB | EXE | AS6_HW_X20SO6300.exe | |
| 描述 |
V6.0 HW Upgrade (X20SO6300) Revision information X20SO6300 Version 3.0.1.0: ID: FUVI-11882 10µs test pulse for HS/HS outputs corrected 10µs test pulse for HS/HS outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\56712_1.fw(651) Version 3.0.0.0: ID:FUVI-11178 Control of the outputs reworked Control of the outputs reworked Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: FUVI-11177 New data sheet V3.0.0 New data sheet V3.0.0 Channel description changed: No Configuration description changed: No Firmware changed: No ID: FUVI-11176 First official release for Safety+ First official releasefor Safety+ Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56712_1.fw(650) Version 2.3.0.1: ID: 783530 Configuration for Power Calculation available The Configuration for Power Calculation is now available in Automation Studio Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\56712_1.fw(573) Version 2.3.0.0: ID: 719705 Failsafe at every boot It could happen under rare conditions that the module is stuck in failsafestate at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data" Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 726590 The power calculation of the modules is supported The datafor the power calculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 727160 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56712_1.fw(573) Version 2.2.1.0: ID: 706305 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 706415 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56712_1.fw(572) Version 2.2.0.0: ID: 688695 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 688875 Propagation delaystatistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 688890 Increased delay of external feedback error detection Increased delay of external feedback error detection Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 688935 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 688950 Improvement of the feedback diagnosis. Improvement of the feedback diagnosis of the output. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\56712_1.fw(571) Version 2.1.0.0: ID: 644320 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications mustbe adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\56712_1.fw(570) Version 1.10.10.0: ID: 622770 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 5\56712_1.fw(331) Version 1.10.9.1: ID: 643445 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\56712_1.fw(330) Version 1.10.9.0: ID: 618195 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 5\56712_1.fw(330) Version 1.10.1.0: ID:552500 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 552530 Loggerentry on negativ edgeof SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 577790 Improve the description section in the OSDD files Improve the descriptionsection in the OSDD files Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 5\56712_1.fw(325) Version 1.10.0.6: ID: 543065 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 543070 Add blackout mode Add blackout mode Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 5\56712_1.fw(320) Version 1.10.0.1: ID: 486415 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 5\56712_1.fw(320) |
|||||
| 版本 | 语言 | 操作系统 | 日期 | 尺寸 | 类型 | 下载 |
| 3.0.0.0 | * | 07/25/2025 | 776 KB | EXE | AS6_HW_X20SO6300.exe | |
| 描述 |
V6.0 HW Upgrade (X20SO6300) Revision information X20SO6300 Version 3.0.0.0: ID: FUVI-11178 Control of the outputs reworked Control of the outputs reworked Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: FUVI-11177 New data sheet V3.0.0 New data sheet V3.0.0 Channel description changed: No Configuration description changed: No Firmware changed: No ID: FUVI-11176 First official release for Safety+ First official release for Safety+ Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56710_1.fw(650) Version 2.6.0.0: ID: 783560 Configuration for Power Calculation available The Configuration for Power Calculation is now available in Automation Studio Channel description changed:No Configuration description changed: Yes Firmware changed: No ID: 784570 New data sheet V2.20 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56710_1.fw(580) Version 2.5.0.0: ID: 719785 Failsafe at every boot It could happen under rare conditions that the module is stuck infailsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data" Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 726650 The power calculation of the modules is supported The data for the power calculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 727180 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56710_1.fw(575) Version 2.4.1.0: ID: 706300 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot timeadjusted. Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 706430 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56710_1.fw(574) Version 2.3.0.0: ID: 670530 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688690 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689735 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689970 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690125 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56710_1.fw(572) Version 2.1.0.0: ID: 644200 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\56710_1.fw(570) Version 1.10.10.1: ID: 643455 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 7\56710_1.fw(331) Version1.10.10.0: ID: 622750 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 7\56710_1.fw(331) Version 1.10.9.0: ID: 618190 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 7\56710_1.fw(330) Version 1.10.1.0: ID: 543030 Improve the description section in the OSDD files Improvethe description section in the OSDD files Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 570635 set SafeOutputOKs even when channel is not mapped SafeOutputOKs are set now even when channel is not mapped Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 582220 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 7\56710_1.fw(325) Version 1.10.0.6: ID: 543025 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 543035 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed:No ID: 543040 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 7\56710_1.fw(320) Version 1.10.0.2: ID: 482610 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 7\56710_1.fw(320) Version 1.10.0.0: ID: 482610 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 7\56710_1.fw(320) |
|||||
| 版本 | 语言 | 操作系统 | 日期 | 尺寸 | 类型 | 下载 |
| 2.3.0.1 | * | 06/24/2024 | 1 MB | EXE | AS6_HW_X20SO6300.exe | |
| 描述 |
V6.0 HW Upgrade (X20SO6300) Revision information X20SO6300 Version 2.3.0.1: ID: 783535 / Support ID: 400412437 Configuration for Power Calculation available The Configuration for Power Calculation isnow available in Automation Studio Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\47125_1.fw(573) Version 2.3.0.0: ID: 719710 Failsafeat every boot It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data" Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 726620 The power calculation of the modules is supported The data for the power calculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 727165 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\47125_1.fw(573) Version 2.2.1.0: ID: 706345 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 706420 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\47125_1.fw(572) Version 2.2.0.0: ID: 688740 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 688880 Propagation delay statistics The Propagation delaystatistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 688895 Increased delay of external feedback error detection Increased delay of external feedback error detection Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 688940 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 688955 Improvement of the feedback diagnosis. Improvement of the feedback diagnosis of the output. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\47125_1.fw(571) Version 2.1.0.0: ID: 644325 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\47125_1.fw(570) Version 1.10.10.0: ID: 622775 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\47125_1.fw(295), 4\47125_1.fw(300), 5\47125_1.fw(331) Version 1.10.9.1: ID: 643450 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47125_1.fw(295), 4\47125_1.fw(300), 5\47125_1.fw(330) Version 1.10.9.0: ID: 618260 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically withlarge projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\47125_1.fw(295), 4\47125_1.fw(300), 5\47125_1.fw(330) Version 1.10.1.0: ID: 532535 Improve the description section in the OSDD files Improve the description section in the OSDD files Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 552495 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 552525 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a loggerentry will be generated Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\47125_1.fw(295), 4\47125_1.fw(300), 5\47125_1.fw(325) Version 1.10.0.6: ID: 532980 Add blackout mode Add blackout mode Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 532985 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 3\47125_1.fw(295), 4\47125_1.fw(300), 5\47125_1.fw(320) Version 1.10.0.1: ID: 488640 Added coated type of module in help Added coated type of module in help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47125_1.fw(295), 4\47125_1.fw(300), 5\47125_1.fw(320) Version 1.10.0.0: ID:470630 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed:No Firmware changed: No ID: 470635 Support of release 1.10including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\47125_1.fw(295), 4\47125_1.fw(300), 5\47125_1.fw(320) Version 1.9.0.0: ID: 413865 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 413975 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channeldescription changed: No Configuration description changed: Yes Firmware changed: No ID: 414245 parameter max. Switching Frequency removed Parameter max. Switching Frequency has no meaning any more. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 414360 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47125_1.fw(295), 4\47125_1.fw(300) Version 1.6.0.8: ID: 388455 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47125_1.fw(295) Version 1.6.0.7: ID: 339285 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47125_1.fw(295) Version 1.6.0.5: ID: 335485 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335490 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47125_1.fw(295) Version 1.6.0.0: ID: 314035 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration descriptionchanged: Yes Firmware changed: No Firmware: 3\47125_1.fw(295) Version 1.5.0.4: ID: 303400 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47125_1.fw(295) Version 1.5.0.0: ID: 294215 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47125_1.fw(295) |
|||||