V4.0 HW Upgrade (5PC901.TS77-09)

DWL@DWL10000307257

版本 语言
操作系统
日期
尺寸
类型 下载
2.0.6.0 * 11/15/2022 579 KB EXE AS4_HW_5PC901.TS77-09.exe
描述 V4.0 HW Upgrade (5PC901.TS77-09)

Revision information 5PC901.TS77-09

Version 2.0.6.0:

ID: 759345
New MTCX FW V01.32 for PPC900
New MTCX FW V01.32 for PPC900 with following changes:
- Optimized internal power supply.
- Bugfix: 5AC901.ICAN-01 (SJA1000 CAN).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(132)

Version 2.0.5.0:

ID: 675950
Wear level of storage medium from AR A4.90
Additional data point to display the wear level in %.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 695785
New MTCX FW V01.31 for PPC900
New MTCX FW V01.31 for PPC900 with following changes:
- Optimization of the SDL interface in combination with DVI panels.
- Bugfix: 5AC901.ISIO-00 did not work in IF-Slot1. The5AC901.ISIO-00 worked without any problems in IF-Slot2.
This problem only affects MTCX version V01.27.
- Bugfix: internal UPS is now also loaded instandby.
This problem only affects MTCX version V01.27.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(131)

Version 2.0.4.0:

ID: 674215
New MTCX FW V01.27 for PPC900
New MTCX FW V01.27 for PPC900 with following changes:
- Optimized internal keyboard syncronization.
- Optimized internal power supply syncronization.
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes

ID: 674225
EPLAN Daten implemented
Channel descriptionchanged: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\57226_0.fw(127)

Version 2.0.3.0:

ID: 644990
Soft reset support for hypervisor target systems.
From version AR 4.71 an independent reboot of AR and GPOS is possible.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\57226_0.fw(126)

Version 2.0.2.0:

ID: 621255
Bugfix for the ETHinternal interface
ModbusTCP and OPC UA areworking now for the ETHinternal.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57226_0.fw(126)

Version 2.0.1.0:

ID: 607155
New MTCX FW V01.26 for PPC900
New MTCX FW V01.26 for PPC900 with following changes:
- Support for IF option 5AC901.I232-00 implemented.
- Enhancements for B&R Hypervisor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(126)

Version 2.0.0.0:

ID: 566580
Preperation to support the B&R Hypervisor
The B&R Hypervisor is supported with Automation Studio versionV4.4.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.1.9.0:

ID: 567905
New MTCX FW V01.25 for PPC900
New MTCX FW V01.25 for PPC900 with following changes:
- Support for B&R Hypervisor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(125)

Version 1.1.8.0:

ID: 552050
Bugfix for VC4 internal datapoints
The internal data points of VC4and illuminated ring keys are working again from Automation Runtime embedded A4.33 on.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57226_0.fw(124)

Version 1.1.7.0:

ID: 507825
Serial number for 5PPC2100 and 5PC901 read incorrectly by function block and SDM
Channel description changed:No
Configuration description changed: No
Firmware changed: No

ID: 533575
New MTCX FW V01.24 for PPC900
New MTCX FW V01.24 for PPC900 with following changes:
- Support for IF option 5AC901.ICAN-01.
- Support syncronization byte for BRADI interface over several OS systems.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(124)

Version 1.1.6.0:

ID: 487380
New MTCX FW V01.23 for PPC900
New MTCX FW V01.23 for PPC900 with following changes:
- Bugfix: sporadical verify problems during a FW upgrade on a Automation Panel connected with SDL. The problemis actually only seen with long SDL cables starting with 20m.
- Optimization of the Suspend/Resume function for USB devices connected withSDL-Link.
- Support for AP5000 Key Extensions.
- Optimization of the maximum inrush current at minimum input voltage of thePPC900 system.
- Bugfix: "Thermal Runaway" effect of the 5AC901.BUPS-xx battery units.
- Optimized SDL equalizer settings.
- Bugfix: with operating temperatures under 5°C, there are sporadic problemsduring the SDL connection establishment using the SDL cable with extender (5CASDL.0xx0-13).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(123)

Version 1.1.5.0:

ID: 438285
New MTCX FW V01.19 for PPC900
New MTCX FW V01.19 for PPC900 with following changes:
- Optimized internal memory handling for the MTCX processor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(119)

Version 1.1.4.0:

ID: 434800
New MTCX FW V01.18 for PPC900
New MTCX FW V01.18 for PPC900 with following changes:
- Support for Panels with external backlight LED driver (e.g.: AP1000).
- Bugfix: if a 5AC901.IUPS-xx (internal UPS) is used without a 5AC901.BUPS-xx (battery unit) under AR, no NMI was generated in a PowerFail case.
With normal UPS operation (with connected battery unit) this problem does not occur.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 436080
Bugfix for Modbus TCP with ARwin
From Automation Studio version 4.1 and ARwin version G4.10 on the PPC900 can be used as Modbus TCP slave.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57226_0.fw(118)

Version1.1.2.0:

ID: 415650
MTCX Upgrade to version V01.17
New MTCX FW V01.17 with following changes:
- Bugfix: sporadic problem with jumping cursor on Intelli touchscreens (customized systems).
- Support: FW upgrade for the external SDL3 converter box (5COSD3.1000-00).
- Optimized measurement interval for the internal temperature sensors.
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes
Firmware: 1\57226_0.fw(117)

Version 1.1.1.0:

ID: 397025
MTCX Upgrade to version V01.15
MTCX V01.14 to V01.15
- Support for IF option 5AC901.ISIO-00.
- Bugfix: negative CPU temperature.
MTCX V01.13 to V01.14
- Support for bus unit 5AC902.BX02-02.
- Optimization PS in standby mode.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(115)

Version 1.1.0.1:

ID: 375195
AS4.x: Ethernet I/O Mapping added

New MTCX version V1.13
AS4.x: When Modbus is activated, the corresponding data points are available in Automation Studio.
MTCX:
-Power supply change because of Clampdiods.
-Power supply change for Ready Relay Module (5V, 3V3 OFF in standby).
-Improved error handling when displayaddressing.
-Workaraund for batteries, which become too hot.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(113)

Version 1.1.0.0:

ID: 373165
Support for 5PC901.TS77-00
The CPU board for Panel PC 900 is supported with Automation Studio V4.0.17.x.
In addition, the minimum version H4.06 or F4.08 of Automation Runtime must beused.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\57226_0.fw(109)
版本 语言
操作系统
日期
尺寸
类型 下载
2.0.5.0 * 11/20/2020 581 KB EXE AS4_HW_5PC901.TS77-09.exe
描述 V4.0 HW Upgrade (5PC901.TS77-09)

Revision information 5PC901.TS77-00

Version 2.0.5.0:

ID: 675950
Wear level of storage medium from AR A4.90
Additional data point to display the wear level in %.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 695785
New MTCX FW V01.31 for PPC900
New MTCX FW V01.31 for PPC900 with following changes:
- Optimization of the SDL interface in combination with DVI panels.
- Bugfix: 5AC901.ISIO-00 did not work in IF-Slot1. The 5AC901.ISIO-00 worked without any problems in IF-Slot2.
This problem only affects MTCX version V01.27.
- Bugfix: internal UPS is now also loaded in standby.
This problem only affects MTCX version V01.27.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(131)

Version 2.0.4.0:

ID: 674215
New MTCX FW V01.27 for PPC900
New MTCX FW V01.27 for PPC900 with following changes:
- Optimized internal keyboard syncronization.
- Optimized internal power supply syncronization.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 674225
EPLAN Daten implemented
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\57226_0.fw(127)

Version 2.0.3.0:

ID: 644990
Soft reset support for hypervisor target systems.
From version AR 4.71 an independent reboot of AR and GPOS is possible.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\57226_0.fw(126)

Version 2.0.2.0:

ID: 621255
Bugfix for the ETHinternal interface
ModbusTCP and OPC UA are working now for the ETHinternal.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57226_0.fw(126)

Version 2.0.1.0:

ID: 607155
New MTCX FW V01.26 for PPC900
New MTCX FW V01.26 for PPC900 with following changes:
- Support for IF option 5AC901.I232-00 implemented.
- Enhancements for B&R Hypervisor.
Channel description changed:No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(126)

Version 2.0.0.0:

ID: 566580
Preperation to support the B&R Hypervisor
The B&R Hypervisor is supportedwith Automation Studio version V4.4.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.1.9.0:

ID: 567905
New MTCX FW V01.25 for PPC900
New MTCX FW V01.25 for PPC900 with following changes:
- Support for B&R Hypervisor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(125)

Version 1.1.8.0:

ID: 552050
Bugfix for VC4 internal datapoints
The internal data points of VC4 and illuminated ring keys are working againfrom Automation Runtime embedded A4.33 on.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57226_0.fw(124)

Version 1.1.7.0:

ID: 507825
Serial number for 5PPC2100 and 5PC901 read incorrectly by function block and SDM
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 533575
New MTCX FW V01.24 for PPC900
New MTCX FW V01.24 for PPC900 with following changes:
- Support for IF option 5AC901.ICAN-01.
- Support syncronization byte for BRADI interface over several OS systems.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(124)

Version 1.1.6.0:

ID: 487380
New MTCX FW V01.23 for PPC900
New MTCX FW V01.23 for PPC900 with following changes:
-Bugfix: sporadical verify problems during a FW upgrade on a Automation Panel connected with SDL. The problem is actually only seen with long SDL cables starting with 20m.
- Optimization of the Suspend/Resume function for USB devices connected withSDL-Link.
- Support for AP5000 Key Extensions.
- Optimization of the maximum inrush current at minimum input voltage of thePPC900 system.
- Bugfix: "Thermal Runaway" effect of the 5AC901.BUPS-xx battery units.
- Optimized SDL equalizer settings.
- Bugfix: with operatingtemperatures under 5°C, there are sporadic problems during the SDL connectionestablishment using the SDL cable with extender (5CASDL.0xx0-13).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(123)

Version 1.1.5.0:

ID: 438285
New MTCX FW V01.19 for PPC900
New MTCX FW V01.19 for PPC900 with following changes:
- Optimized internal memory handling for the MTCX processor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(119)

Version 1.1.4.0:

ID: 434800
New MTCX FW V01.18 for PPC900
New MTCX FW V01.18 for PPC900 with following changes:
- Support for Panels with external backlight LED driver (e.g.: AP1000).
- Bugfix: ifa 5AC901.IUPS-xx (internal UPS) is used without a 5AC901.BUPS-xx(battery unit) under AR, no NMI was generated in a PowerFail case.
With normal UPS operation (with connected battery unit) this problem does not occur.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 436080
Bugfix for Modbus TCP with ARwin
From Automation Studio version 4.1 and ARwin version G4.10 on the PPC900can be used as Modbus TCP slave.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57226_0.fw(118)

Version 1.1.2.0:

ID: 415650
MTCX Upgradeto version V01.17
New MTCX FW V01.17 with following changes:
- Bugfix: sporadic problem with jumping cursor on Intelli touchscreens (customized systems).
- Support: FW upgrade for the external SDL3 converter box (5COSD3.1000-00).
- Optimized measurement interval for the internal temperature sensors.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(117)

Version 1.1.1.0:

ID: 397025
MTCX Upgrade to version V01.15
MTCX V01.14 to V01.15
- Support for IF option 5AC901.ISIO-00.
- Bugfix: negative CPU temperature.
MTCX V01.13 to V01.14
- Support for bus unit 5AC902.BX02-02.
- Optimization PS in standby mode.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(115)

Version 1.1.0.1:

ID: 375195
AS4.x: Ethernet I/O Mapping added

New MTCX version V1.13
AS4.x: When Modbus is activated, the corresponding data points are available in Automation Studio.
MTCX:
-Power supply change because of Clampdiods.
-Power supply change for Ready Relay Module (5V, 3V3 OFF in standby).
-Improved error handling when display addressing.
-Workaraund for batteries, which become too hot.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(113)

Version 1.1.0.0:

ID: 373165
Support for 5PC901.TS77-00
The CPU board for Panel PC 900 is supported with Automation Studio V4.0.17.x.
In addition, the minimum version H4.06 or F4.08 of Automation Runtimemust be used.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\57226_0.fw(109)
版本 语言
操作系统
日期
尺寸
类型 下载
2.0.4.0 * 02/07/2020 573 KB EXE AS4_HW_5PC901.TS77-09.exe
描述 V4.0 HW Upgrade (5PC901.TS77-09)

Revision information 5PC901.TS77-00

Version 2.0.4.0:

ID: 674215
New MTCX FW V01.27 for PPC900
New MTCX FW V01.27 for PPC900 with following changes:
- Optimized internal keyboard syncronization.
- Optimized internal power supply syncronization.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 674225
EPLAN Daten implemented
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\57226_0.fw(127)

Version 2.0.3.0:

ID: 644990
Soft reset support for hypervisor target systems.
From version AR 4.71 an independent reboot of AR and GPOS is possible.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\57226_0.fw(126)

Version 2.0.2.0:

ID: 621255
Bugfix for the ETHinternal interface
ModbusTCP and OPC UA are working now for the ETHinternal.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57226_0.fw(126)

Version 2.0.1.0:

ID: 607155
New MTCX FW V01.26 for PPC900
New MTCX FW V01.26 for PPC900 with following changes:
- Support for IF option 5AC901.I232-00 implemented.
- Enhancements for B&R Hypervisor.
Channel description changed:No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(126)

Version 2.0.0.0:

ID: 566580
Preperation to support the B&R Hypervisor
The B&R Hypervisor is supportedwith Automation Studio version V4.4.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.1.9.0:

ID: 567905
New MTCX FW V01.25 for PPC900
New MTCX FW V01.25 for PPC900 with following changes:
- Support for B&R Hypervisor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(125)

Version 1.1.8.0:

ID: 552050
Bugfix for VC4 internal datapoints
The internal data points of VC4 and illuminated ring keys are working againfrom Automation Runtime embedded A4.33 on.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57226_0.fw(124)

Version 1.1.7.0:

ID: 507825
Serial number for 5PPC2100 and 5PC901 read incorrectly by function block and SDM
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 533575
New MTCX FW V01.24 for PPC900
New MTCX FW V01.24 for PPC900 with following changes:
- Support for IF option 5AC901.ICAN-01.
- Support syncronization byte for BRADI interface over several OS systems.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(124)

Version 1.1.6.0:

ID: 487380
New MTCX FW V01.23 for PPC900
New MTCX FW V01.23 for PPC900 with following changes:
-Bugfix: sporadical verify problems during a FW upgrade on a Automation Panel connected with SDL. The problem is actually only seen with long SDL cables starting with 20m.
- Optimization of the Suspend/Resume function for USB devices connected withSDL-Link.
- Support for AP5000 Key Extensions.
- Optimization of the maximum inrush current at minimum input voltage of thePPC900 system.
- Bugfix: "Thermal Runaway" effect of the 5AC901.BUPS-xx battery units.
- Optimized SDL equalizer settings.
- Bugfix: with operatingtemperatures under 5°C, there are sporadic problems during the SDL connectionestablishment using the SDL cable with extender (5CASDL.0xx0-13).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(123)

Version 1.1.5.0:

ID: 438285
New MTCX FW V01.19 for PPC900
New MTCX FW V01.19 for PPC900 with following changes:
- Optimized internal memory handling for the MTCX processor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(119)

Version 1.1.4.0:

ID: 434800
New MTCX FW V01.18 for PPC900
New MTCX FW V01.18 for PPC900 with following changes:
- Support for Panels with external backlight LED driver (e.g.: AP1000).
- Bugfix: ifa 5AC901.IUPS-xx (internal UPS) is used without a 5AC901.BUPS-xx(battery unit) under AR, no NMI was generated in a PowerFail case.
With normal UPS operation (with connected battery unit) this problem does not occur.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 436080
Bugfix for Modbus TCP with ARwin
From Automation Studio version 4.1 and ARwin version G4.10 on the PPC900can be used as Modbus TCP slave.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57226_0.fw(118)

Version 1.1.2.0:

ID: 415650
MTCX Upgradeto version V01.17
New MTCX FW V01.17 with following changes:
- Bugfix: sporadic problem with jumping cursor on Intelli touchscreens (customized systems).
- Support: FW upgrade for the external SDL3 converter box (5COSD3.1000-00).
- Optimized measurement interval for the internal temperature sensors.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(117)

Version 1.1.1.0:

ID: 397025
MTCX Upgrade to version V01.15
MTCX V01.14 to V01.15
- Support for IF option 5AC901.ISIO-00.
- Bugfix: negative CPU temperature.
MTCX V01.13 to V01.14
- Support for bus unit 5AC902.BX02-02.
- Optimization PS in standby mode.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(115)

Version 1.1.0.1:

ID: 375195
AS4.x: Ethernet I/O Mapping added

New MTCX version V1.13
AS4.x: When Modbus is activated, the corresponding data points are available in Automation Studio.
MTCX:
-Power supply change because of Clampdiods.
-Power supply change for Ready Relay Module (5V, 3V3 OFF in standby).
-Improved error handling when display addressing.
-Workaraund for batteries, which become too hot.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(113)

Version 1.1.0.0:

ID: 373165
Support for 5PC901.TS77-00
The CPU board for Panel PC 900 is supported with Automation Studio V4.0.17.x.
In addition, the minimum version H4.06 or F4.08 of Automation Runtimemust be used.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\57226_0.fw(109)
版本 语言
操作系统
日期
尺寸
类型 下载
2.0.3.0 * 05/17/2019 522 KB EXE AS4_HW_5PC901.TS77-09.exe
描述 V4.0 HW Upgrade (5PC901.TS77-09)

Revision information 5PC901.TS77-00

Version 2.0.3.0:

ID: 644990
Soft reset support for hypervisor target systems.
From version AR 4.71 an independent reboot of AR and GPOS is possible.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\57226_0.fw(126)

Version 2.0.2.0:

ID: 621255
Bugfix for the ETHinternal interface
ModbusTCP and OPC UA are working now for the ETHinternal.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57226_0.fw(126)

Version 2.0.1.0:

ID: 607155
New MTCX FW V01.26 for PPC900
New MTCX FW V01.26 for PPC900 with following changes:
- Support for IF option 5AC901.I232-00 implemented.
- Enhancements for B&R Hypervisor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(126)

Version 2.0.0.0:

ID: 566580
Preperation to support the B&R Hypervisor
The B&R Hypervisor is supported with Automation Studio version V4.4.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.1.9.0:

ID: 567905
New MTCX FW V01.25 for PPC900
New MTCX FW V01.25 for PPC900 with following changes:
- Support for B&RHypervisor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(125)

Version 1.1.8.0:

ID: 552050
Bugfix for VC4 internal datapoints
The internal data points of VC4 and illuminated ring keys are working againfrom Automation Runtime embedded A4.33 on.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57226_0.fw(124)

Version 1.1.7.0:

ID: 507825
Serial number for 5PPC2100 and 5PC901 read incorrectly by function block and SDM
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 533575
New MTCX FW V01.24 for PPC900
New MTCX FW V01.24 for PPC900 with following changes:
- Support for IF option 5AC901.ICAN-01.
- Support syncronization byte for BRADI interface over several OS systems.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(124)

Version 1.1.6.0:

ID: 487380
New MTCXFW V01.23 for PPC900
New MTCX FW V01.23 for PPC900 with following changes:
- Bugfix: sporadical verify problems during a FW upgrade on a Automation Panel connected with SDL. The problem is actually only seen with long SDL cables starting with 20m.
- Optimization of the Suspend/Resume function for USB devices connected withSDL-Link.
- Support for AP5000 Key Extensions.
- Optimization of the maximum inrush current at minimum input voltage ofthe PPC900 system.
- Bugfix: "Thermal Runaway" effect of the 5AC901.BUPS-xx battery units.
- Optimized SDL equalizer settings.
- Bugfix: with operating temperatures under 5°C, there are sporadic problemsduring the SDL connection establishment using the SDL cable with extender (5CASDL.0xx0-13).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(123)

Version 1.1.5.0:

ID: 438285
New MTCX FW V01.19 for PPC900
New MTCX FW V01.19 for PPC900 with following changes:
- Optimized internal memory handling for the MTCX processor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(119)

Version 1.1.4.0:

ID: 434800
New MTCX FW V01.18 for PPC900
New MTCX FW V01.18 for PPC900 with following changes:
- Support for Panels with external backlight LED driver (e.g.: AP1000).
- Bugfix: if a 5AC901.IUPS-xx (internal UPS) is used without a 5AC901.BUPS-xx (battery unit) under AR, no NMI was generated in a PowerFail case.
With normal UPS operation (with connected battery unit) this problem does not occur.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 436080
Bugfix for Modbus TCP with ARwin
From Automation Studio version 4.1 and ARwin version G4.10 on the PPC900 can be used as Modbus TCP slave.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57226_0.fw(118)

Version 1.1.2.0:

ID: 415650
MTCXUpgrade to version V01.17
New MTCX FW V01.17 with following changes:
- Bugfix: sporadic problem with jumping cursor on Intelli touchscreens (customized systems).
- Support: FW upgrade for the external SDL3 converter box (5COSD3.1000-00).
- Optimized measurement interval for the internal temperature sensors.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(117)

Version 1.1.1.0:

ID: 397025
MTCX Upgrade to version V01.15
MTCX V01.14 to V01.15
- Support for IF option 5AC901.ISIO-00.
- Bugfix: negative CPU temperature.
MTCX V01.13 to V01.14
- Support for bus unit 5AC902.BX02-02.
- Optimization PS in standby mode.
Channel description changed: No
Configuration description changed: No
Firmwarechanged: Yes
Firmware: 1\57226_0.fw(115)

Version 1.1.0.1:

ID: 375195
AS4.x: Ethernet I/O Mapping added

New MTCX version V1.13
AS4.x: When Modbus is activated, the corresponding data points are available in Automation Studio.
MTCX:
-Power supply change because of Clampdiods.
-Power supply change for Ready Relay Module (5V, 3V3 OFF in standby).
-Improved error handling when display addressing.
-Workaraund for batteries, which become too hot.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(113)

Version 1.1.0.0:

ID: 373165
Support for 5PC901.TS77-00
The CPU board for Panel PC 900 is supported with Automation Studio V4.0.17.x.
In addition, the minimum version H4.06 or F4.08 of AutomationRuntime must be used.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\57226_0.fw(109)
版本 语言
操作系统
日期
尺寸
类型 下载
2.0.2.0 * 12/06/2018 904 KB EXE AS4_HW_5PC901.TS77-09.exe
描述 V4.0 HW Upgrade (5PC901.TS77-09)

Revision information 5PC901.TS77-00

Version 2.0.2.0:

ID: 621255
Bugfix for the ETHinternal interface
ModbusTCP and OPC UA are working now for the ETHinternal.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57226_0.fw(126)

Version 2.0.1.0:

ID: 607155
New MTCX FW V01.26 for PPC900
New MTCX FW V01.26 for PPC900 with following changes:
- Support for IF option 5AC901.I232-00 implemented.
- Enhancements for B&R Hypervisor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(126)

Version 2.0.0.0:

ID: 566580
Preperation to support the B&R Hypervisor
The B&R Hypervisor is supported with Automation Studio version V4.4.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.1.9.0:

ID: 567905
New MTCX FW V01.25 for PPC900
New MTCX FW V01.25 for PPC900 with following changes:
- Support for B&R Hypervisor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(125)

Version 1.1.8.0:

ID: 552050
Bugfix for VC4 internal datapoints
The internal data points of VC4 and illuminated ring keys are working againfrom Automation Runtime embedded A4.33 on.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57226_0.fw(124)

Version 1.1.7.0:

ID: 507825
Serial number for 5PPC2100 and 5PC901 read incorrectly by function block and SDM
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 533575
New MTCX FW V01.24 forPPC900
New MTCX FW V01.24 for PPC900 with following changes:
- Support for IF option 5AC901.ICAN-01.
- Support syncronization byte for BRADI interface over several OS systems.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(124)

Version 1.1.6.0:

ID: 487380
New MTCX FWV01.23 for PPC900
New MTCX FW V01.23 for PPC900 with following changes:
- Bugfix: sporadical verify problems during a FW upgrade on a Automation Panel connected with SDL. The problem is actually only seen with long SDL cables starting with 20m.
- Optimization of the Suspend/Resume function for USBdevices connected with SDL-Link.
- Support for AP5000 Key Extensions.
- Optimization of the maximum inrush current at minimum input voltage of thePPC900 system.
- Bugfix: "Thermal Runaway" effect of the 5AC901.BUPS-xx battery units.
- Optimized SDL equalizer settings.
- Bugfix: with operating temperatures under 5°C, there are sporadic problemsduring the SDL connection establishment using the SDL cable with extender (5CASDL.0xx0-13).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(123)

Version 1.1.5.0:

ID: 438285
New MTCX FW V01.19 for PPC900
New MTCX FW V01.19 for PPC900 with following changes:
- Optimized internal memory handlingfor the MTCX processor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(119)

Version 1.1.4.0:

ID: 434800
New MTCX FW V01.18 for PPC900
New MTCX FW V01.18 for PPC900 with following changes:
- Support for Panels with external backlight LED driver (e.g.: AP1000).
- Bugfix: if a 5AC901.IUPS-xx (internal UPS) is used without a 5AC901.BUPS-xx (battery unit) under AR, no NMI was generated in a PowerFail case.
With normalUPS operation (with connected battery unit) this problem does not occur.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 436080
Bugfix for Modbus TCP with ARwin
From Automation Studio version 4.1 and ARwin version G4.10 on the PPC900 can be used as Modbus TCP slave.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57226_0.fw(118)

Version 1.1.2.0:

ID: 415650
MTCX Upgrade to version V01.17
New MTCX FW V01.17 with following changes:
- Bugfix: sporadic problem with jumping cursor on Intelli touchscreens (customized systems).
- Support: FW upgrade for the external SDL3 converter box (5COSD3.1000-00).
- Optimized measurement interval for the internal temperature sensors.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(117)

Version 1.1.1.0:

ID: 397025
MTCX Upgrade to version V01.15
MTCX V01.14 to V01.15
- Support for IF option 5AC901.ISIO-00.
- Bugfix: negative CPU temperature.
MTCX V01.13 to V01.14
- Support for bus unit 5AC902.BX02-02.
- Optimization PS in standby mode.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(115)

Version 1.1.0.1:

ID: 375195
AS4.x: Ethernet I/O Mapping added

New MTCX version V1.13
AS4.x: When Modbus is activated, the corresponding data points are available in Automation Studio.
MTCX:
-Power supply change because of Clampdiods.
-Power supply change for Ready Relay Module (5V, 3V3 OFF in standby).
-Improved error handling when display addressing.
-Workaraund for batteries,which become too hot.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(113)

Version 1.1.0.0:

ID: 373165
Support for 5PC901.TS77-00
The CPU board for Panel PC 900 is supported with Automation Studio V4.0.17.x.
In addition, the minimum version H4.06 or F4.08 of Automation Runtime must beused.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\57226_0.fw(109)
版本 语言
操作系统
日期
尺寸
类型 下载
2.0.1.0 * 09/26/2018 904 KB EXE AS4_HW_5PC901.TS77-09.exe
描述 V4.0 HW Upgrade (5PC901.TS77-09)

Revision information 5PC901.TS77-00

Version 2.0.1.0:

ID: 607155
New MTCX FW V01.26 for PPC900
New MTCX FW V01.26 for PPC900 with following changes:
- Support for IFoption 5AC901.I232-00 implemented.
- Enhancements for B&R Hypervisor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(126)

Version 2.0.0.0:

ID: 566580
Preperation to support the B&R Hypervisor
The B&R Hypervisor is supported with Automation Studio version V4.4.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.1.9.0:

ID: 567905
New MTCX FWV01.25 for PPC900
New MTCX FW V01.25 for PPC900 with following changes:
- Support for B&R Hypervisor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(125)

Version 1.1.8.0:

ID: 552050
Bugfix for VC4 internal datapoints
The internal data points of VC4 and illuminated ring keys are working againfrom Automation Runtime embedded A4.33 on.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57226_0.fw(124)

Version 1.1.7.0:

ID: 507825
Serial number for 5PPC2100 and 5PC901 read incorrectlyby function block andSDM
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 533575
New MTCX FW V01.24 for PPC900
New MTCX FW V01.24 for PPC900 with following changes:
- Support for IF option 5AC901.ICAN-01.
- Support syncronization byte for BRADI interface over several OS systems.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(124)

Version 1.1.6.0:

ID:487380
New MTCX FW V01.23 for PPC900
New MTCX FW V01.23 for PPC900 with following changes:
- Bugfix: sporadical verify problems during a FW upgrade on a Automation Panel connected with SDL. The problem is actually only seen with long SDL cables starting with 20m.
- Optimization of the Suspend/Resume function for USB devices connected withSDL-Link.
- Support for AP5000 Key Extensions.
- Optimization of the maximum inrush current at minimum input voltage of thePPC900 system.
- Bugfix: "Thermal Runaway" effect of the 5AC901.BUPS-xx battery units.
- Optimized SDL equalizer settings.
- Bugfix: with operating temperatures under 5°C, there are sporadic problemsduring the SDL connection establishment using the SDL cable with extender (5CASDL.0xx0-13).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(123)

Version 1.1.5.0:

ID: 438285
New MTCX FW V01.19 for PPC900
New MTCX FW V01.19 for PPC900 with following changes:
- Optimized internal memory handling for the MTCX processor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(119)

Version 1.1.4.0:

ID: 434800
New MTCX FW V01.18 for PPC900
New MTCX FW V01.18 for PPC900 with following changes:
- Support for Panels with external backlight LED driver (e.g.: AP1000).
- Bugfix: if a 5AC901.IUPS-xx (internal UPS) is used without a 5AC901.BUPS-xx (battery unit) under AR, no NMI was generated in a PowerFail case.
With normal UPS operation (with connected battery unit) this problem does not occur.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 436080
Bugfix for Modbus TCP with ARwin
From Automation Studio version 4.1 and ARwin version G4.10 on the PPC900 can be used as Modbus TCP slave.
Channel description changed: No
Configuration description changed: No
Firmwarechanged: No
Firmware: 1\57226_0.fw(118)

Version 1.1.2.0:

ID: 415650
MTCX Upgrade to version V01.17
New MTCX FW V01.17 with following changes:
- Bugfix: sporadic problem with jumping cursor on Intelli touchscreens (customized systems).
- Support: FW upgrade for the external SDL3 converter box (5COSD3.1000-00).
- Optimized measurement interval for the internal temperature sensors.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(117)

Version 1.1.1.0:

ID: 397025
MTCX Upgrade to version V01.15
MTCX V01.14 to V01.15
- Support for IF option 5AC901.ISIO-00.
- Bugfix: negative CPU temperature.
MTCX V01.13 to V01.14
- Support for bus unit 5AC902.BX02-02.
- Optimization PS in standby mode.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(115)

Version 1.1.0.1:

ID: 375195
AS4.x: Ethernet I/O Mapping added

NewMTCX version V1.13
AS4.x: When Modbus is activated, the corresponding data points are available in Automation Studio.
MTCX:
-Power supply changebecause of Clampdiods.
-Power supply change for Ready Relay Module (5V, 3V3 OFF in standby).
-Improved error handling when display addressing.
-Workaraund for batteries, which become too hot.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(113)

Version 1.1.0.0:

ID: 373165
Support for 5PC901.TS77-00
The CPU board for Panel PC 900 is supportedwith Automation Studio V4.0.17.x.
In addition, the minimum version H4.06 or F4.08 of Automation Runtime must beused.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\57226_0.fw(109)
版本 语言
操作系统
日期
尺寸
类型 下载
1.1.9.0 * 12/21/2017 960 KB EXE AS4_HW_5PC901.TS77-09.exe
描述 V4.0 HW Upgrade (5PC901.TS77-09)

Revision information 5PC901.TS77-00

Version 1.1.9.0:

ID: 567905
New MTCX FW V01.25 for PPC900
New MTCX FW V01.25 for PPC900 with following changes:
- Support for B&R Hypervisor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(125)

Version 1.1.8.0:

ID: 552050
Bugfix for VC4 internal datapoints
The internal data points of VC4 and illuminated ring keys are working againfrom Automation Runtime embedded A4.33 on.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57226_0.fw(124)

Version 1.1.7.0:

ID: 507825
Serial number for 5PPC2100 and 5PC901 read incorrectly by function block and SDM
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 533575
New MTCX FW V01.24 for PPC900
New MTCX FW V01.24 for PPC900 with following changes:
- Support for IF option 5AC901.ICAN-01.
- Support syncronization byte for BRADI interface over several OS systems.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(124)

Version 1.1.6.0:

ID: 487380
New MTCX FW V01.23 for PPC900
New MTCX FW V01.23 for PPC900 with following changes:
- Bugfix: sporadical verify problems during a FW upgrade on a Automation Panel connected with SDL. The problem is actually only seen with long SDL cables starting with 20m.
- Optimization of the Suspend/Resume function for USB devices connected withSDL-Link.
- Support for AP5000 Key Extensions.
- Optimization of the maximum inrush current at minimum input voltage of thePPC900 system.
- Bugfix: "Thermal Runaway" effect of the 5AC901.BUPS-xx battery units.
- Optimized SDL equalizer settings.
- Bugfix: withoperating temperatures under 5°C, there are sporadic problems during the SDL connection establishment using the SDL cable with extender (5CASDL.0xx0-13).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(123)

Version 1.1.5.0:

ID: 438285
New MTCX FW V01.19 for PPC900
New MTCX FWV01.19 for PPC900 with following changes:
- Optimized internal memory handling for the MTCX processor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(119)

Version 1.1.4.0:

ID: 434800
New MTCX FW V01.18 for PPC900
New MTCX FW V01.18 for PPC900 with following changes:
- Support for Panels with external backlight LED driver (e.g.: AP1000).
- Bugfix: if a 5AC901.IUPS-xx (internal UPS) is used without a 5AC901.BUPS-xx (battery unit) under AR, no NMI was generated in a PowerFail case.
With normal UPS operation (with connected battery unit) this problem does not occur.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 436080
Bugfix for Modbus TCP with ARwin
From Automation Studio version 4.1 and ARwin version G4.10 on the PPC900 can be used as Modbus TCP slave.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57226_0.fw(118)

Version 1.1.2.0:

ID: 415650
MTCX Upgrade to version V01.17
New MTCX FW V01.17 with following changes:
- Bugfix: sporadic problem with jumping cursor on Intelli touchscreens (customized systems).
- Support: FW upgrade for the external SDL3 converter box (5COSD3.1000-00).
- Optimized measurement interval for the internal temperature sensors.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(117)

Version 1.1.1.0:

ID: 397025
MTCX Upgrade to version V01.15
MTCX V01.14 to V01.15
- Support for IF option 5AC901.ISIO-00.
- Bugfix: negative CPU temperature.
MTCX V01.13 to V01.14
- Support forbus unit 5AC902.BX02-02.
- Optimization PS in standby mode.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(115)

Version 1.1.0.1:

ID: 375195
AS4.x: Ethernet I/O Mapping added

New MTCX version V1.13
AS4.x: When Modbus is activated, the corresponding data points are available in Automation Studio.
MTCX:
-Power supply change because of Clampdiods.
-Power supply change for Ready Relay Module (5V, 3V3 OFF in standby).
-Improved error handling when display addressing.
-Workaraund for batteries, which become too hot.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(113)

Version 1.1.0.0:

ID: 373165
Support for 5PC901.TS77-00
The CPU board for Panel PC 900 is supported with Automation Studio V4.0.17.x.
In addition, the minimum version H4.06 or F4.08 of Automation Runtime must beused.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\57226_0.fw(109)