DWL@DWL10000840973

Версия Язык
Операционная система
Дата
Размер
Тип Загрузка
3.0.0.1 * 18.08.2026 2 МБ EXE AS6_HW_X20SM1446-1.exe
Описание V6.0 HW Upgrade (X20SM1446-1)

Revision information X20SM1446-1

Version 3.0.0.1:

ID: QCAS-3535
CVE-2025-43715: Installer is vulnerable to local privilege escalation
The installation system NSIS used byB&R can allow local attackers to escalate their privileges.
CVE-2025-43715, CVSS: 8.1 (High) CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 3.0.0.0:

ID: RKFY-8837
Support forX2X+ networks
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\62384_1.fw(19)

Version 2.3.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed:yes
Firmware changed: no

Version 2.2.1.0:

ID: 674155
Function model names adapted
Uniform function model names for all stepper modules
Channel description changed: No
Configuration descriptionchanged: Yes
Firmware changed: No

ID: 686370
AS3 Upgrade bug fixed
Support for AS3.08 restored
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\62384_1.fw(19)

Version 2.2.0.0:

ID: 669465
Support for mappMotion
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 672300
Error in SGT configuration in HWC fixed
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware:1\62384_1.fw(19)

Version 1.4.0.0:

ID: 662205
Revised function model "Ramp" mode -122
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 670025
Module documentation revised
Data sheet V1.26
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\62384_1.fw(19)

Version 1.3.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.2.0.0:

ID: 638090
Module documentation revised
Data sheet V1.20
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 653775
Ramp function model: referencing now also possible with DI4
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 653780
Troubleshooting in the Function Model ramp in mode -121
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\62384_1.fw(17)

Version1.1.0.0:

ID: 626515
Overtemperature shutdown adjusted to 116 ° C
Channel description changed: No
Configuration description changed:No
Firmware changed: Yes

ID: 626540
Module documentation revised
Data sheet V1.11
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\62384_1.fw(15)

Version 1.0.0.1:

ID: 609305
support for X20BR7300
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\62384_1.fw(10)
Версия Язык
Операционная система
Дата
Размер
Тип Загрузка
3.0.0.0 * 02.12.2025 2 МБ EXE AS6_HW_X20SM1446-1.exe
Описание V6.0 HW Upgrade (X20SM1446-1)

Revision information X20SM1446-1

Version 3.0.0.0:

ID: RKFY-8837
Support for X2X+ networks
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\62384_1.fw(19)

Version 2.3.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 2.2.1.0:

ID: 674155
Function model namesadapted
Uniform function model names for all stepper modules
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 686370
AS3 Upgrade bug fixed
Support for AS3.08 restored
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\62384_1.fw(19)

Version 2.2.0.0:

ID: 669465
Support for mappMotion
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 672300
Error in SGT configuration in HWC fixed
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\62384_1.fw(19)

Version 1.4.0.0:

ID: 662205
Revised function model "Ramp" mode -122
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 670025
Module documentation revised
Data sheet V1.26
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\62384_1.fw(19)

Version 1.3.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.2.0.0:

ID: 638090
Module documentation revised
Data sheet V1.20
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 653775
Ramp function model: referencing now also possible with DI4
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 653780
Troubleshooting in the Function Model ramp in mode -121
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\62384_1.fw(17)

Version 1.1.0.0:

ID:626515
Overtemperature shutdown adjusted to 116 ° C
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 626540
Module documentation revised
Data sheetV1.11
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\62384_1.fw(15)

Version 1.0.0.1:

ID: 609305
support for X20BR7300
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\62384_1.fw(10)