DWL@DWL10000843941
| Версия | Язык | Операционная система | Дата | Размер | Тип | Загрузка |
|---|---|---|---|---|---|---|
| 1.4.0.0 | * | 14.10.2026 | 853 кБ | EXE | AS6_HW_X20cAI4632-1.exe | |
| Описание |
V6.0 HW Upgrade (X20cAI4632-1) Revision information X20cAI4632-1 Version 1.4.0.0: ID: TDYD-12876 Adjustment of synchronization monitoring Synchronization Monitoring Revised (applies to modules ≥ Rev. H0) The synchronization monitoring has been optimized. At large X2X cycle times (starting at approx. 4000 μs), false triggers of the "SyncStatus" data point (red LED) occurred. This issue had no impact on the accuracy of the analoginput values, but only affected the error detection of the synchronization status. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\54650_2.fw(10), 1\54650_3.fw(104) Version 1.3.0.2: ID: Firmware signature enables automatic verification of the authenticity on the target system The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source. Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.3.0.1: ID: QCAS-3535 CVE-2025-43715: Installer is vulnerable to local privilege escalation The installation system NSIS used by B&R can allow local attackers toescalate their privileges. CVE-2025-43715, CVSS: 8.1 (High) CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.3.0.0: ID: TDYD-10420 Support new hardware variant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\54650_2.fw(10), 1\54650_3.fw(103) Version 1.2.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.7.0: ID: 609900 Module documentation revised Data sheet V3.05 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\54650_2.fw(10) Version 1.0.5.0: ID: 522220 Module documentation revised Data sheet V3.02 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\54650_2.fw(10) Version 1.0.0.0: ID: 342510 Support X20cAI4632-1 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\54650_2.fw(10) |
|||||
| Версия | Язык | Операционная система | Дата | Размер | Тип | Загрузка |
| 1.3.0.2 | * | 06.10.2026 | 853 кБ | EXE | AS6_HW_X20cAI4632-1.exe | |
| Описание |
V6.0 HW Upgrade (X20cAI4632-1) Revision information X20cAI4632-1 Version 1.3.0.2: ID: Firmware signature enables automatic verification of the authenticity on the target system The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source. Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.3.0.1: ID: QCAS-3535 CVE-2025-43715: Installer is vulnerable to local privilege escalation The installation system NSIS used by B&R can allow local attackers toescalate their privileges. CVE-2025-43715, CVSS: 8.1 (High) CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H Channel description changed: no Configuration description changed:yes Firmware changed: no Version 1.3.0.0: ID: TDYD-10420 Support new hardware variant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\54650_2.fw(10), 1\54650_3.fw(103) Version 1.2.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.7.0: ID: 609900 Module documentation revised Data sheet V3.05 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\54650_2.fw(10) Version 1.0.5.0: ID: 522220 Module documentation revised Data sheet V3.02 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\54650_2.fw(10) Version 1.0.0.0: ID: 342510 Support X20cAI4632-1 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\54650_2.fw(10) |
|||||
| Версия | Язык | Операционная система | Дата | Размер | Тип | Загрузка |
| 1.3.0.1 | * | 18.08.2026 | 845 кБ | EXE | AS6_HW_X20cAI4632-1.exe | |
| Описание |
V6.0 HW Upgrade (X20cAI4632-1) Revision information X20cAI4632-1 Version 1.3.0.1: ID: QCAS-3535 CVE-2025-43715: Installer is vulnerable to local privilege escalation The installation system NSIS used by B&R can allow local attackers toescalate their privileges. CVE-2025-43715, CVSS: 8.1 (High) CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H Channeldescription changed: no Configuration description changed: yes Firmware changed: no Version 1.3.0.0: ID: TDYD-10420 Support new hardware variant 3 Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 1\54650_2.fw(10), 1\54650_3.fw(103) Version 1.2.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.7.0: ID: 609900 Module documentation revised Data sheet V3.05 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\54650_2.fw(10) Version 1.0.5.0: ID: 522220 Module documentation revised Data sheet V3.02 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\54650_2.fw(10) Version 1.0.0.0: ID: 342510 Support X20cAI4632-1 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\54650_2.fw(10) |
|||||
| Версия | Язык | Операционная система | Дата | Размер | Тип | Загрузка |
| 1.3.0.0 | * | 15.01.2026 | 845 кБ | EXE | AS6_HW_X20cAI4632-1.exe | |
| Описание |
V6.0 HW Upgrade (X20cAI4632-1) Revision information X20cAI4632-1 Version 1.3.0.0: ID: TDYD-10420 Support new hardware variant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\54650_2.fw(10), 1\54650_3.fw(103) Version 1.2.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.7.0: ID: 609900 Module documentation revised Data sheet V3.05 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\54650_2.fw(10) Version 1.0.5.0: ID: 522220 Module documentation revised Data sheet V3.02 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\54650_2.fw(10) Version 1.0.0.0: ID: 342510 Support X20cAI4632-1 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\54650_2.fw(10) |
|||||