DWL@DWL10000812754
| Versão | Idiomas | Sistema operacional | Data | Tamanho | Tipos | Download |
|---|---|---|---|---|---|---|
| 2.6.2.0 | * | 02/28/2025 | 22 MB | EXE | AS6_HW_8I86xxxxxxx.0P-1xx.exe | |
| Descrição |
V6.0 HW Upgrade (8I86xxxxxxx.0P-1xx) Revision information 8I86xxxxxxx.0P-1xx Version 2.6.2.0: ID: QCAS-452 PDO mapping filter of AIxC und THxV revised If an analog temperature input is set to "PTC management" and the corresponding optional monitoring data point is activated, the resistivity value is transmitted to the I/O mapping. Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\64526_1.fw(201), 1\64526_30.fw(201) Version 2.6.1.0: ID: 764050 Adaption of SSI encoder Configuration is transfered correctly with a SSI encoder connected Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 777305 Boost setting: "Conical Motor" adapation Adaption of boost settings to support "conical motor" with asynchronous motors Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\64526_1.fw(201), 1\64526_30.fw(201) Version 2.6.0.0: ID: 743745 Parameter UECV revised Insome cases, the ComboBox for parameter UECV offered too many options. TheComboBox is now restricted to options that are supported by drive. Hence, CFIfault are avoided during a project download. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 754475 Interaction between communication card and drive revised Up to now, the internal communication between communication card and drive was kept on Schneider's default setting. Now, operation mode was adapted to thecircumstances of a POWERLINK network.. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\64526_1.fw(201), 1\64526_30.fw(201) Version 2.5.1.0: ID: 742215 mappMotion inplementation restored Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 742280 Parameter ABMF revised The module configurationoffers valid values for parameter ABMF only. Hence,the parameter will be download correctly without error. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 742810 Harmonization of module configuration (Group: Axis management) Theuser surfaces for the product group ACOPOSinverter was designed specially. One demands is to provide a homogeneous structure for all devices of the productgeneration. This harmonization of several device from different vendors results in a similar commissioning process and simplisfies a product change within the product group. The extension of the product group by the ACPi P96 forced adaptions of the general structure. These changes are rolled out to the products that have already been published. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\64526_1.fw(180) Version 2.5.0.0: ID: 738365 Continuous product improvement Optimization of initial commissioning. Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\64526_1.fw(180) Version 2.4.0.0: ID: 710230 DS402-PLK-objects revised Revision and correction ofPLK object 0x6060, 0x6061 and 0x6502 (DS402 operation mode) Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 727235 POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438) POWERLINK Security Vulnerability (CVE-2020-13987) The POWERLINK IP stack was affected by a security vulnerability impacting thechecksum calculation of TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IP stack was affected by a securityvulnerability impacting fragmented packet reassembly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 727265 NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 727280 Boot routine of PLK communication card revised The state of the reset-line of the inverter is now taken into account during re/booting Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 727300 Parameter FLR revised The parameter FLR is added to the module configuration in Automation Studio. It turn on the function "Catch on the fly", that permitts the restart of a coasting motor (motor in freewheel stop). Channel description changed: No Configurationdescription changed: Yes Firmware changed: No ID: 730200 Automation Runtime versions greater D3.10 supported Support of Automation Runtime versions greater D3.10 (up to now minimum version required was D4.10) Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\64526_1.fw(170) Version 2.3.1.0: ID: 702145 SDO download error eliminated Module configurations for closed loop motor control in combination with activated holding brake (function "BLC" brake logic control) can be downloaded without SDO download error. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 702805 Module documentation revised User manual V 1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\64526_1.fw(160) Version 2.3.0.0: ID: 701210 Boot behavior revised On few devices, several powercycles or reboots could lead to an ILF-error, which then has to be acknowledged by another powercycle. This behavoir was changed (better timings between inverter and option card) so that no ILF-error occurs on powerup. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 701220 Support for automatic DNA configuration from AS 4.9.1 Channeldescription changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\64526_1.fw(160) Version 2.2.1.0: ID: 672970 Support ACOPOSinverter P86-P (frame size 1,2,3) Support for AutomationStudio Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 689300 Support for mappMotion; ACPi P86-P (frame size 1,2,3) Support for mappMotion (from version 5.11) The usage of the onboard POWERLINK interfaces onARM CPUs (e.g. X20CP04xx) formappMotion is restricted to the following minimum versions of AutomationRuntime; M4.34, F4.45, C4.53, C4.63, A4.72 Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\64526_1.fw(150) |
|||||