DWL@DWL10000433716

Versão Idiomas
Sistema operacional
Data
Tamanho
Tipos Download
1.10.13.0 * 03/20/2024 3 MB EXE AS4_HW_X20SI8110.exe
Descrição V4.0 HW Upgrade (X20SI8110)

Revision information X20SI8110

Version 1.10.13.0:

ID: 780365
Correction of the input filter with set "Filter off".
Correction of the input filter, if a "Filter off" is set and a channel error is detected.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59202_1.fw(340)

Version 1.10.12.0:

ID: 710640
Timing of module internal communication updated
The timing of the module internal communication was updated. Sporadic errors 98818, 119317, 99348, 102914, 99350 no longer occur.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 710805
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring of module cycle time and slot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59202_1.fw(333)

Version 1.10.11.1:

ID: 692695
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 692595 / Support ID: 400299371
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59202_1.fw(332)

Version 1.10.10.0:

ID: 670230
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 668675
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59202_1.fw(331)

Version 1.10.9.1:

ID: 643470
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(330)

Version 1.10.9.0:

ID: 618230
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59202_1.fw(330)

Version 1.10.1.0:

ID: 575525
add PhysicalStateChannels on X20SLX842
add PhysicalStateChannels on X20SLX842.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 575530
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 575535
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 575540
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 577395 / Support ID: 400234330
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(325)

Version 1.10.0.6:

ID: 533070
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 543080
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 543085
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(322)

Version 1.10.0.3:

ID: 463885
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\59202_1.fw(322)
Versão Idiomas
Sistema operacional
Data
Tamanho
Tipos Download
1.10.12.0 * 04/16/2021 3 MB EXE AS4_HW_X20SI8110.exe
Descrição V4.0 HW Upgrade (X20SI8110)

Revision information X20SI8110

Version 1.10.12.0:

ID: 710640
Timing of module internal communication updated
The timing of the module internal communication was updated. Sporadic errors 98818, 119317, 99348, 102914, 99350 no longer occur.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 710805
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring of module cycle time and slot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59202_1.fw(333)

Version 1.10.11.1:

ID: 692695
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 692595 / Support ID: 400299371
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59202_1.fw(332)

Version 1.10.10.0:

ID: 670230
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 668675
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59202_1.fw(331)

Version 1.10.9.1:

ID: 643470
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(330)

Version 1.10.9.0:

ID: 618230
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59202_1.fw(330)

Version 1.10.1.0:

ID: 575525
add PhysicalStateChannels on X20SLX842
add PhysicalStateChannels on X20SLX842.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 575530
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 575535
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 575540
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 577395 / Support ID: 400234330
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(325)

Version 1.10.0.6:

ID: 533070
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 543080
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 543085
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(322)

Version 1.10.0.3:

ID: 463885
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\59202_1.fw(322)
Versão Idiomas
Sistema operacional
Data
Tamanho
Tipos Download
1.10.11.1 * 12/10/2020 2 MB EXE AS4_HW_X20SI8110.exe
Descrição V4.0 HW Upgrade (X20SI8110)

Revision information X20SI8110

Version 1.10.11.1:

ID: 692695
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 692595 / Support ID: 400299371
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 7\59202_1.fw(332)

Version 1.10.10.0:

ID: 670230
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 668675
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59202_1.fw(331)

Version 1.10.9.1:

ID: 643470
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(330)

Version 1.10.9.0:

ID: 618230
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59202_1.fw(330)

Version 1.10.1.0:

ID: 575525
add PhysicalStateChannels on X20SLX842
add PhysicalStateChannels on X20SLX842.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 575530
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 575535
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 575540
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 577395 / Support ID: 400234330
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(325)

Version 1.10.0.6:

ID: 533070
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 543080
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 543085
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(322)

Version 1.10.0.3:

ID: 463885
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\59202_1.fw(322)
Versão Idiomas
Sistema operacional
Data
Tamanho
Tipos Download
1.10.9.2 * 01/31/2020 2 MB EXE AS4_HW_X20SI8110.exe
Descrição V4.0 HW Upgrade (X20SI8110)

Revision information X20SI8110

Version 1.10.9.2:

ID: 670230
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(330)

Version 1.10.9.1:

ID: 643470
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(330)

Version 1.10.9.0:

ID: 618230
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59202_1.fw(330)

Version 1.10.1.0:

ID: 575525
add PhysicalStateChannels on X20SLX842
add PhysicalStateChannels on X20SLX842.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 575530
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 575535
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 575540
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 577395 / Support ID: 400234330
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(325)

Version 1.10.0.6:

ID: 533070
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 543080
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 543085
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(322)

Version 1.10.0.3:

ID: 463885
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\59202_1.fw(322)
Versão Idiomas
Sistema operacional
Data
Tamanho
Tipos Download
1.10.9.1 * 05/16/2019 2 MB EXE AS4_HW_X20SI8110.exe
Descrição V4.0 HW Upgrade (X20SI8110)

Revision information X20SI8110

Version 1.10.9.1:

ID: 643470
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(330)

Version 1.10.9.0:

ID: 618230
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59202_1.fw(330)

Version 1.10.1.0:

ID: 575525
add PhysicalStateChannels on X20SLX842
add PhysicalStateChannels on X20SLX842.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 575530
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 575535
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 575540
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 577395 / Support ID: 400234330
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(325)

Version 1.10.0.6:

ID: 533070
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 543080
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 543085
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(322)

Version 1.10.0.3:

ID: 463885
first official release
first official release
Channel description changed:Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\59202_1.fw(322)
Versão Idiomas
Sistema operacional
Data
Tamanho
Tipos Download
1.10.9.0 * 11/08/2018 2 MB EXE AS4_HW_X20SI8110.exe
Descrição V4.0 HW Upgrade (X20SI8110)

Revision information X20SI8110

Version 1.10.9.0:

ID: 618230
logger entry 112174, 108078
Loggerentry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59202_1.fw(330)

Version 1.10.1.0:

ID: 575525
add PhysicalStateChannels on X20SLX842
add PhysicalStateChannels on X20SLX842.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 575530
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 575535
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 575540
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 577395 / Support ID: 400234330
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(325)

Version 1.10.0.6:

ID: 533070
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 543080
New default values
The default valuesfor "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 543085
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(322)

Version 1.10.0.3:

ID: 463885
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware:1\59202_1.fw(322)
Versão Idiomas
Sistema operacional
Data
Tamanho
Tipos Download
1.10.1.0 * 03/05/2018 2 MB EXE AS4_HW_X20SI8110.exe
Descrição V4.0 HW Upgrade (X20SI8110)

Revision information X20SI8110

Version 1.10.1.0:

ID: 575525
add PhysicalStateChannels on X20SLX842
add PhysicalStateChannels on X20SLX842.
Channel description changed:Yes
Configuration description changed: No
Firmware changed: Yes

ID: 575530
Adapt filter algorithm to eliminate dependencies betweenTON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 575535
Provide CRC of the Firmware
Provide CRCof the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 575540
New default values
The default values for "Filter On" and "Discrepancy Time" havebeen modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 577395 / Support ID: 400234330
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(325)

Version 1.10.0.6:

ID: 533070
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 543080
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration descriptionchanged: Yes
Firmware changed: No

ID: 543085
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(322)

Version 1.10.0.3:

ID: 463885
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\59202_1.fw(322)
Versão Idiomas
Sistema operacional
Data
Tamanho
Tipos Download
1.10.0.6 * 10/04/2017 2 MB EXE AS4_HW_X20SI8110.exe
Descrição V4.0 HW Upgrade (X20SI8110)

Revision information X20SI8110

Version 1.10.0.6:

ID: 533070
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 543080
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 543085
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\59202_1.fw(322)

Version 1.10.0.3:

ID: 463885
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\59202_1.fw(322)
Loading