V3.0 HW Upgrade (5PP5IF.FXCM-00)

DWL@DWL10000241104

Versie Taal
Besturingssysteem
Datum
Grootte
Type Download
2.0.2.1 * 28-06-2013 480 KB EXE AS3.0_HW_5PP5IF.FXCM-00.exe
Omschrijving V3.0 HW Upgrade (5PP5IF.FXCM-00)

Revision information 5PP5IF.FXCM-00

Version 2.0.2.1:

ID: 340510
APROL support added for AS4.x
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\48029_0.pci(3), 1\48029b0.can(122)

Version 2.0.2.0:

ID: 331130 / Support ID: 400108191
Routing not possible - faulty hwd parameter
A faulty hwd parameter in the hardware description file has been removed.
Routing via the CAN interface is now possible.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\48029_0.pci(3), 1\48029b0.can(122)

Version 2.0.1.0:

ID: 278375
Increasing the available storage area for remanent data + Important information!
In conjunction with this upgrade - from the Automation Runtime version B4.01 on a storage area of 256kB can be used to save remanent datas in the SRAM.

Attention, important information: If this upgrade will be installed in conjunction with Automation Runtime >= A4.01,
it is absolutely necassery because of a conceptual change in the hardware representation,
that all of the components of used PP500/APC5xx have a version >= V2.0.0.0,
otherwise it may be compatibility problems with the used Automation Runtime.
Affected are the following components: 5PP5##* (system units), 5PP5CP* (CPUboards), 5PP5IF* (interface boards), 5PP5IO* (I / O boards).
Channel descriptionchanged: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\48029_0.pci(3), 1\48029b0.can(122)

Version 1.0.1.0:

ID: 271785
Problem with UserRAM
The problem, that the Power Panel 500 reboots cyclic when using the UserRAMarea, has been fixed.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\48029_0.pci(3), 1\48029b0.can(122)

Version 1.0.0.0:

ID: 261095
Support for 5PP5IF.FXCM-00
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\48029_0.pci(1), 1\48029b0.can(122)
Versie Taal
Besturingssysteem
Datum
Grootte
Type Download
2.0.1.0 * 01-03-2012 480 KB EXE AS3.0_HW_5PP5IF.FXCM-00.exe
Omschrijving V3.0 HW Upgrade (5PP5IF.FXCM-00)

Revision information 5PP5IF.FXCM-00

Version 2.0.1.0:

ID: 278375
Increasing the available storage area for remanent data + Important information!
In conjunction with this upgrade - from the Automation Runtime version B4.01 on a storage area of 256kB can be used to save remanent datas in the SRAM.

Attention, important information: If this upgrade will be installed in conjunction with Automation Runtime >= A4.01,
it is absolutely necassery because of a conceptual change in the hardware representation,
that all of the components of used PP500/APC5xx have a version >= V2.0.0.0,
otherwise it may be compatibility problems with the used Automation Runtime.
Affected are the following components: 5PP5##* (system units), 5PP5CP* (CPU boards), 5PP5IF* (interface boards),5PP5IO* (I / O boards).
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\48029_0.pci(3), 1\48029b0.can(122)

Version 1.0.1.0:

ID: 271785
Problem with UserRAM
The problem, that the Power Panel 500 reboots cyclic when using the UserRAMarea, has been fixed.
Channel description changed:No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\48029_0.pci(3), 1\48029b0.can(122)

Version 1.0.0.0:

ID: 261095
Support for 5PP5IF.FXCM-00
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\48029_0.pci(1), 1\48029b0.can(122)
Loading