DWL@DWL10000327781
| Versie | Taal | Besturingssysteem | Datum | Grootte | Type | Download |
|---|---|---|---|---|---|---|
| 1.3.1.0 | * | 25-04-2019 | 2 MB | EXE | AS2.6_HW_X67MM2436.exe | |
| Omschrijving |
V2.6 HW Upgrade (X67MM2436) Revision information X67MM2436 Version 1.3.1.0: ID: 600100 Module documentation revised Data sheet V2.34 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 1\8819_1.fw(100), 1\8819_2.fw(100), 1\8819_3.fw(100) Version 1.3.0.0: ID: 463215 support HW Variante 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8819_1.fw(100), 1\8819_2.fw(100), 1\8819_3.fw(100) Version 1.2.0.0: ID: 374900 / Support ID: 400130265 X67MM2436 - same encoder functionality like X20MM2436 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\8819_1.fw(8), 1\8819_2.fw(8) Version 1.1.0.2: ID: 320995 Removed wrong filter value in channel description Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\8819_1.fw(6), 1\8819_2.fw(6) Version 1.1.0.0: ID: 188250 / Support ID: 400009741 Support at CANIO bus controller with SG3 target Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 307635 Module bootup timeout configured Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\8819_1.fw(6), 1\8819_2.fw(6) Version 1.0.1.0: ID: 263755 / Support ID: 400069673 X67MM2436 on CANIO Controller leads to malfunction of subsequent modules ->Repair by means of correction of erroneous HWC-entry Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\8819_1.fw(6), 1\8819_2.fw(6) Version 1.0.0.1: ID: 177375 HWC file has to be better documented 4-Quadrant-Mode was implemented Channel description changed: Yes Configuration descriptionchanged: No Firmware changed: No Firmware: 1\8819_1.fw(6), 1\8819_2.fw(6) |
|||||
| Versie | Taal | Besturingssysteem | Datum | Grootte | Type | Download |
| 1.3.0.0 | * | 03-02-2016 | 2 MB | EXE | AS2.6_HW_X67MM2436.exe | |
| Omschrijving |
V2.6 HW Upgrade (X67MM2436) Revision information X67MM2436 Version 1.3.0.0: ID: 463215 support HW Variante 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8819_1.fw(100), 1\8819_2.fw(100), 1\8819_3.fw(100) Version 1.2.0.0: ID: 374900 / Support ID: 400130265 X67MM2436 - same encoder functionality like X20MM2436 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\8819_1.fw(8), 1\8819_2.fw(8) Version 1.1.0.2: ID: 320995 Removed wrong filter value in channel description Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\8819_1.fw(6), 1\8819_2.fw(6) Version 1.1.0.0: ID: 188250 / Support ID: 400009741 Support at CANIObus controller with SG3 target Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 307635 Module bootup timeout configured Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\8819_1.fw(6), 1\8819_2.fw(6) Version 1.0.1.0: ID: 263755 / Support ID: 400069673 X67MM2436 on CANIO Controller leads to malfunction of subsequent modules ->Repair by means of correction of erroneous HWC-entry Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\8819_1.fw(6), 1\8819_2.fw(6) Version 1.0.0.1: ID: 177375 HWC file has to be better documented 4-Quadrant-Mode was implemented Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\8819_1.fw(6), 1\8819_2.fw(6) |
|||||