DWL@DWL10000840915
| Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
|---|---|---|---|---|---|---|
| 1.8.0.0 | * | 01/12/2025 | 3 Mo | EXE | AS6_HW_X20RT8201.exe | |
| Description |
V6.0 HW Upgrade (X20RT8201) Revision information X20RT8201 Version 1.8.0.0: ID: TDYD-9559 Corrected dead time behavior in the rtiPWM function block Dead time can be activated via bit 3 in the “Mode” register Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58714_2.fw(433), 1\58714_3.fw(433), 1\58714_4.fw(433) Version 1.7.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.6.1.0: ID: 689435 Limitation of the cycle time Channel description changed: No Configuration description changed: No Firmwarechanged: No ID: 689465 Module documentation revised Data sheet V 1.15 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58714_2.fw(430), 1\58714_3.fw(430), 1\58714_4.fw(430) Version 1.6.0.0: ID: 650585 Additional status bit for rtiABRPos reference impulse loss An additional status bit was introduced, that detects the loss of the reference impulse signals. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58714_2.fw(430), 1\58714_3.fw(430), 1\58714_4.fw(430) Version 1.5.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.4.0.0: ID: 623550 Bootup time significantly increases with upgrade V1.3.0.0 of X20RT8201 Bootup time has been improved Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58714_2.fw(420), 1\58714_3.fw(420), 1\58714_4.fw(420) Version 1.3.1.0: ID: 601830 Correction HWX-File Parameter specification corrected Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58714_2.fw(420), 1\58714_3.fw(420), 1\58714_4.fw(420) Version 1.3.0.0: ID: 594485 Support new hw variante 4 with fw v420 Solvingbootup problems Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 594895 Added configuration "blackout mode" Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 600645 Module documentation revised Data sheet V 1.13 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58714_2.fw(420), 1\58714_3.fw(420), 1\58714_4.fw(420) Version 1.2.0.0: ID: 590135 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTsand LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591725 Module documentation revised Data sheet V 1.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58714_2.fw(420), 1\58714_3.fw(420) Version 1.1.1.0: ID: 530770 Module documentation revised Data sheet V1.10 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58714_2.fw(320), 1\58714_3.fw(320) Version 1.1.0.0: ID: 426125 Support X20RT8201 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58714_2.fw(240), 1\58714_3.fw(240) |
|||||