DWL@DWL10000849332
| Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
|---|---|---|---|---|---|---|
| 1.5.3.0 | * | 18/03/2026 | 6 Mo | EXE | AS4_HW_X90CP174.48-S1.exe | |
| Description |
V4.12 HW Upgrade (X90CP174.48-S1) Revision information X90CP174.48-S1 Version 1.5.3.0: ID: RKFY-11585 Incorrect Description Text for Dither The description text for Dither will be removed. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 2\60703_1.fp(54) Version 1.5.1.0: ID: 786030 Enhancements for AS6/AR6 - configurable IpForwarding. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 2\60703_1.fp(54) Version 1.2.0.0: ID: 779390 Operating mode iCN on POWERLINK: spurious connection problem to the managerafter power fail corrected Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 780695 Error in AB counter mode fixed. When a channel was configured as "Digital input source", the "Counter" Register was not reset to zero after reboot. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 2\60703_1.fp(54) Version 1.1.3.0: ID: 761670 X2X bus output cycle trigger error correction The X2X bus output cycle trigger was not started although it was configured. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 761730 Register description of the sensor supply corrected Value "1" was stated as "not OK", which is incorrect Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 2\60703_1.fp(52) Version 1.1.2.0: ID: 743050 Broadcast channels missing in PLK interface Due to the change to Powerlink type 6, the broadcast channels have to be included. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 2\60703_1.fp(52) Version 1.1.1.0: ID: 729155 Support for POWERLINK type 6 The module now supports POWERLINK type 6 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 729205 Support for 6 A current onparallel channels When two 6 A channels are used in parallel mode, a total current of 12 A isnow possible. Attention: When using 4 A and 6 A channelsin parallel, each channel can only supply 4 A. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 2\60703_1.fp(52) Version 1.1.0.0: ID: 704465 Disable AB encoder on channel 2 when ABR is configured on channel 1. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 717915 Enables second CPU core for I/Oprocessing The I/O input processing can be assigned to the the second CPU core. This frees CPU processing power to be used by the application. Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 2\60703_1.fp(52) Version 1.0.4.0: ID: 694795 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 694815 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 2\60703_1.fp(52) Version 1.0.3.0: ID: 590240 First Version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 2\60703_1.fp(52) |
|||||