DWL@DWL10000064148
| Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
|---|---|---|---|---|---|---|
| 1.9.1.0 | * | 17/07/2015 | 3 Mo | EXE | AS3.0_HW_X20SI2100.exe | |
| Description |
V3.0 HW Upgrade (X20SI2100) Revision information X20SI2100 Version 1.9.1.0: ID: 424610 change of input filter The behaviour of the input filter has changed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424615 Update Online Help Update Online Help V1.91 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 424620 fw valid from SafetyRelease 1.4 on Thefirmware is used for all SafetyReleases from 1.4 on. Channel descriptionchanged: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7957_1.fw(262), 2\7957_1.fw(273), 6\7957_1.fw(301) Version 1.9.0.0: ID: 413820 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 413925 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channeldescription changed: No Configuration description changed: Yes Firmware changed: No ID: 414280 2-channel evaluation: additional information at warning If warning "discrepancy time elapsed" appears for 2-channel evaluation, info0 will now display the chosen PLCopen FBK (equivalent or antivalent). Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 414325 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7957_1.fw(262), 2\7957_1.fw(273), 3\7957_1.fw(282), 4\7957_1.fw(290), 5\7957_1.fw(300) Version 1.6.0.8: ID: 388390 The module also supports SafetyRelease 1.8 Starting with this version, the module alsosupports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7957_1.fw(262), 2\7957_1.fw(273), 3\7957_1.fw(282), 4\7957_1.fw(290) Version1.6.0.7: ID: 339235 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7957_1.fw(262), 2\7957_1.fw(273), 3\7957_1.fw(282), 4\7957_1.fw(290) Version 1.6.0.5: ID: 335345 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335350 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7957_1.fw(262), 2\7957_1.fw(273), 3\7957_1.fw(282), 4\7957_1.fw(290) Version 1.6.0.0: ID: 313665 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7957_1.fw(262), 2\7957_1.fw(273), 3\7957_1.fw(282), 4\7957_1.fw(290) Version 1.5.0.4: ID: 303360 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7957_1.fw(262), 2\7957_1.fw(273), 3\7957_1.fw(282), 4\7957_1.fw(290) Version 1.5.0.3: ID: 287420 New feature: discrepancy time increased from 500ms to 10s Discrepancy time maximum from 500ms to 10s increased. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 290245 Datasheet Version 1.50 Datasheet version 1.50 added in Html format Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 1\7957_1.fw(262), 2\7957_1.fw(273), 3\7957_1.fw(282), 4\7957_1.fw(290) Version 1.4.1.3: ID: 284600 Release für kompatibles Safety Release 1.5 ID 284600 Parameter for backwards compatibility in description file changed Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7957_1.fw(262), 2\7957_1.fw(273), 3\7957_1.fw(282) Version 1.4.1.1: ID: 272595 Release for Safety Release 1.5 Release for Safety Release 1.5 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7957_1.fw(262), 2\7957_1.fw(273), 3\7957_1.fw(282) Version 1.4.0.1: ID#225420: Safety Release 1.4 - one can configure the channel that shall be used as pulse source for testpulse with mode "internal" (see manual) - different levels for logger entires: "Info", "Warning" or "Error" (ARB3.05 required) - logger entries with level "Info" or "Warning" are sent by only 1 of the 2safety processors to reduce the number of messages - X2X diagnostics data points (AR 3.08 required) Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Version 1.2.1.0: ID#210370: Pulse_Mode "external": automatic increment of "Filter_off_us" For Pulse_Mode "external" the automatic increment of parameter "Filter_off_us" was less than the 5ms described in the documentation. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID#219325: erroneous discrepancy time error message An erroneous discrepancy time error message could be generated at startup by the 2 channel evaluation if external devices are used that generatetest pulses. Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.2.0.3: ID#217720: changes in HWC fixed typosof safety parameters enabled for AR B2.96 Channel description changed: No Configuration description changed: Yes Firmware changed: No Version 1.2.0.0: ID#183260: reduced async communication at boot time parameters are stored locally and will only be transmitted in case of changes Channel description changed: No Configuration description changed: No Firmware changed: Yes ID#186455: flashing of SE-LEDs new states of SE-LEDs: single flash: safety firmware is still instate PreOp (waiting for startcommand from SL) double flash: safetyfirmware is in operational, but cyclic data connectionto SL is not valid Channel description changed: No Configuration description changed: No Firmware changed: Yes ID#194140: increasedmaximum value of input filters input filters can be paramtrized up to 500ms (instead of 100ms) Channel description changed: No Configuration description changed: No Firmwarechanged: No ID#199330: operation in cold environment problems when operating in cold environment (0 .. 10°C) solved (logger entries 99850 und 103946) Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.1.4.0: ID#168365: solved sporadic firmware update problems solved sporadic firmware update problems Channel description changed: No Configuration description changed: No Firmware changed: No Version 1.1.3.0: ID#180045: enhacements HWC state information of 2-channel evaluation can be mapped Aprol support Channel description changed: No Configuration description changed: No Firmware changed: No Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7957_1.fw(262), 2\7957_1.fw(273), 3\7957_1.fw(282) Version 1.1.1.0: ID: 163785 First official Release First official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7957_1.fw(259) |
|||||