3IF771.9

Short description
Communication module 1x CAN bus
General information
Status indicators Transmitting/Receiving data for IF1
Diagnostics
Data transfer Yes, using LED status indicators
Power consumption
3.3 VDC 0.64 W
5 VDC 0.66 W
Total 1.3 W
Electrical isolation
PLC - IF1 Yes
Certifications
CE Yes
UKCA Yes
HazLoc cULus HazLoc E180196
Industrial control equipment
for hazardous locations
Class I, Division 2, Groups ABCD
KC Yes
Interfaces
Interface IF1
Signal CAN bus
Variant 4-pin male multipoint connector
Max. distance 1000 m
Transfer rate Max. 500 kbit/s
Operating conditions
Degree of protection per EN 60529 IP20
Ambient conditions
Temperature
Operation 0 to 60°C
Storage -25 to 70°C
Relative humidity
Operation 5 to 95%, non-condensing
Mechanical properties
Note Order 1x terminal block TB704 separately.
Slot Slot, e.g. in the CP360
Número de material:
3IF771.9
Descripción:
  • CAN bus connection as single interface
aPCI interface module, 1 CAN bus interface, max. 500 kbit/s, electrically isolated, network-capable, object buffer in the transmit and receive directions, order 1x terminal block TB704 separately!
Accesorios obligatorios
Terminal blocks
0TB704.9 Accessory terminal block, 4-pin, screw clamp terminal block 2.5 mm²
0TB704.91 Accessory terminal block, 4-pin, push-in terminal block 2.5 mm²
Accesorios opcionales
Infrastructure components
0AC913.93 Bus adapter, CAN bus, 2 CAN bus interfaces, including 03 m attachment cable (TB704)
Actualizaciones de hardware de Automation Studio Versión (fecha) Descargar
V2.6 HW Upgrade (3IF771.9) EXE / 449 KB
V3.0 HW Upgrade (3IF771.9) EXE / 449 KB
V4.0 HW Upgrade (3IF771.9) EXE / 346 KB
Documentación Versión (fecha) Descargar
Datasheet 3IF771.9 PDF / 271 KB

Seleccione país e idioma