| Versión | Idioma | Sistema operativo | Fecha | Tamaño | Tipo | Descargar |
|---|---|---|---|---|---|---|
| 2.18.0.0 | * | 29.08.2025 | 3 MB | EXE | AS4_HW_X67BC8331.exe | |
| Descripción |
V4.0 HW Upgrade (X67BC8331) Revision information X67BC8331 Version 2.18.0.0: ID: RKFY-10000 Support new HW-variant 8 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(438), 1\42917_3.fw(438), 1\42917_6.fw(438) Version 2.17.0.0: ID: RKFY-9695 Added capability to disable Fast Link Down detection In the event of interferences on the network cable, the active Fast Link Down Detection very quickly leads to acomplete loss of the link and thus to a failure of all subsequent stations. The Fast Link Down Detection can now be deactivated, which means that minor faults on the cable have less impact. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(438), 1\42917_3.fw(438) Version 2.15.0.0: ID: 758850 Optimization of asynchronous register access Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(433), 1\42917_3.fw(433) Version 2.14.0.0: ID: 737340 NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 737345 POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438) POWERLINK Security Vulnerability (CVE-2020-13987) The POWERLINK IP stack was affected by a security vulnerability impacting thechecksum calculation of TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IP stack was affected by a security vulnerability impacting fragmented packet reassembly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 739455 Module documentation revised Data sheet V3.08 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(432), 1\42917_3.fw(432) Version 2.11.1.0: ID: 697885 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(430), 1\42917_3.fw(430) Version 2.11.0.0: ID: 664420 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665800 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665880 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666165 Module documentation revised Data sheet V3.06 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(430), 1\42917_3.fw(430) Version 2.9.3.0: ID: 639730 Alignment of AS output according to the FieldBusDesigner Channel description changed: No Configuration description changed: Yes Firmwarechanged: No Firmware: 1\42917_1.fw(427), 1\42917_3.fw(427) Version 2.9.0.0: ID: 629050 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629125 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629200 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629245 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(427), 1\42917_3.fw(427) Version 2.8.0.0: ID: 619240 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619270 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619650 Firmwareupdate of X2XLink module at POWERLINK Stations does not work since H4.34 Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming. Problem occurs on BC and SL: X20BC0083 X20cBC0083 < HW-Upgrade 2.2.0.0 X20BC1083 X20cBC1083 < HW-Upgrade 2.5.0.0 X20BC8083 X20cBC8083 < HW-Upgrade 2.5.0.0 X20BC8084 X20cBC8084 < HW-Upgrade 2.5.0.0 X20SL8101 X20cSL8101 X67BC81RT.L12 < HW-Upgrade 2.5.0.0 X67BC8321-1 X67BC8331 X67BC8513.L12 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 621720 Display of further diagnostic data points in the I / O mapping of theX2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(426), 1\42917_3.fw(426) Version 2.5.6.0: ID: 603859 APROL: missing attribute for channel-parameter with "Sig_*" inserted. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version 2.5.5.0: ID: 551155 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version 2.5.4.0: ID: 540355 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(419), 1\42917_3.fw(419) Version2.5.2.0: ID: 493920 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(415), 1\42917_3.fw(415) Version 2.5.0.0: ID: 468210 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468215 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468220 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468580 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(413), 1\42917_3.fw(413) Version 2.2.0.0: ID: 460145 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460265 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(411), 1\42917_3.fw(411) Version 2.1.0.0: ID: 439140 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439245 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(400), 1\42917_3.fw(400), 1\42917_5.fw(400) Version 2.0.0.0: ID: 390310 Uncommon X2X settings causepermanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(210), 1\42917_3.fw(210) Version 1.3.4.0: ID: 310880 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 311045 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>-RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(168), 1\42917_3.fw(168) Version 1.3.3.0: ID: 305185 ACOPOSmulti with SafeMC, asynchronous communication lost When there wasa high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(167), 1\42917_3.fw(167) Version 1.3.2.0: ID: 299005 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(165), 1\42917_3.fw(165) Version 1.3.1.0: ID: 289035 Certain X2Xconfigurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(163), 1\42917_3.fw(163) Version 1.3.0.0: ID: 277195 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277765 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(160), 1\42917_3.fw(160) Version 1.2.0.0: ID: 246690 DNA support; Update behavior on X2X busof the BC improved - DNA support (Dynamic Node Allocation) - fasterupdating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 - support for Simulation device added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(152), 1\42917_3.fw(152) Version 1.0.8.0: ID: 218520 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(145) Version 1.0.7.0: ID: 214450 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(144) Version 1.0.6.0: ID: 210945 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(143) Version 1.0.5.0: ID: 209765 Extensions and Bugfixes - New ASICS will be set to 3mA output current (A&P 182905) - Optimization of SDO communication (unnecessary acknowledges removed) - Support ofcommands ReadMultipleParameter / WriteMultipleParameter - NodeID assignment by digital inputs supported (NodeId 241 and 242) - Minor corrections certification - ASnd frames with unknown ServiceID could disturb the BC (only possible with 3rd party MN) - Access to not existing objects in OD could cause firmware crash - When running X2X cycle times <200 us the X2X Bus was not working correctly (A&P 190630) - When in state PREOP_2 no SoCis received for 10sec the BC will fall back in PREOP_1 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(142) Version 1.0.0.0: ID: 190480 Support X67BC8331 Support X67BC8331, first version Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(141) |
|||||
| Versión | Idioma | Sistema operativo | Fecha | Tamaño | Tipo | Descargar |
| 2.17.0.0 | * | 14.05.2025 | 3 MB | EXE | AS4_HW_X67BC8331.exe | |
| Descripción |
V4.0 HW Upgrade (X67BC8331) Revision information X67BC8331 Version 2.17.0.0: ID: RKFY-9695 Added capability to disable Fast Link Down detection In the event of interferences on the network cable, the active Fast Link Down Detection very quickly leads to a complete loss of the link and thus to a failure of all subsequent stations. The Fast Link Down Detection can now be deactivated, which means that minor faults on the cable have less impact. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(438), 1\42917_3.fw(438) Version 2.15.0.0: ID: 758850 Optimizationof asynchronous register access Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(433), 1\42917_3.fw(433) Version 2.14.0.0: ID: 737340 NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 737345 POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438) POWERLINK Security Vulnerability (CVE-2020-13987) The POWERLINK IP stack was affected by a security vulnerability impacting thechecksum calculation of TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IP stack was affected by a security vulnerability impacting fragmented packet reassembly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 739455 Module documentation revised Data sheet V3.08 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(432), 1\42917_3.fw(432) Version 2.11.1.0: ID: 697885 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(430), 1\42917_3.fw(430) Version 2.11.0.0: ID: 664420 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665800 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665880 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666165 Module documentation revised Data sheet V3.06 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(430), 1\42917_3.fw(430) Version 2.9.3.0: ID: 639730 Alignment of AS output according to the FieldBusDesigner Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(427), 1\42917_3.fw(427) Version 2.9.0.0: ID:629050 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629125 DNA: BC as head-end station switching hub off again Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 629200 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629245 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(427), 1\42917_3.fw(427) Version 2.8.0.0: ID: 619240 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619270 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619650 Firmwareupdate of X2XLink module at POWERLINK Stations does not work since H4.34 Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming. Problem occurs on BC and SL: X20BC0083 X20cBC0083 < HW-Upgrade 2.2.0.0 X20BC1083 X20cBC1083 < HW-Upgrade 2.5.0.0 X20BC8083 X20cBC8083 < HW-Upgrade2.5.0.0 X20BC8084 X20cBC8084 < HW-Upgrade 2.5.0.0 X20SL8101 X20cSL8101 X67BC81RT.L12 < HW-Upgrade 2.5.0.0 X67BC8321-1 X67BC8331 X67BC8513.L12 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No ID: 621720 Display of further diagnostic data points in the I / O mapping of the X2X interface from theX67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(426), 1\42917_3.fw(426) Version 2.5.6.0: ID: 603859 APROL:missing attribute for channel-parameter with "Sig_*" inserted. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version 2.5.5.0: ID: 551155 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version 2.5.4.0: ID: 540355 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(419), 1\42917_3.fw(419) Version 2.5.2.0: ID: 493920 First POWERLINK UDP ASnd SDO transfert after long time takes up to5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(415), 1\42917_3.fw(415) Version 2.5.0.0: ID: 468210 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468215 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468220 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468580 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(413), 1\42917_3.fw(413) Version 2.2.0.0: ID: 460145 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460265 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wennSLXhinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(411), 1\42917_3.fw(411) Version 2.1.0.0: ID: 439140 I/O modulesbehind POWERLINK bus controllers no longer achieving Operationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439245 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\42917_1.fw(400), 1\42917_3.fw(400), 1\42917_5.fw(400) Version 2.0.0.0: ID: 390310 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 1\42917_1.fw(210), 1\42917_3.fw(210) Version 1.3.4.0: ID: 310880 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311045 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(168), 1\42917_3.fw(168) Version 1.3.3.0: ID: 305185 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(167), 1\42917_3.fw(167) Version 1.3.2.0: ID: 299005 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(165), 1\42917_3.fw(165) Version 1.3.1.0: ID: 289035 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(163), 1\42917_3.fw(163) Version 1.3.0.0: ID: 277195 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277765 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(160), 1\42917_3.fw(160) Version 1.2.0.0: ID: 246690 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 - support for Simulation device added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(152), 1\42917_3.fw(152) Version 1.0.8.0: ID: 218520 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(145) Version 1.0.7.0: ID: 214450 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessedfasterthan allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(144) Version 1.0.6.0: ID: 210945 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(143) Version 1.0.5.0: ID: 209765 Extensions and Bugfixes - New ASICS will beset to 3mA output current (A&P 182905) - Optimization of SDO communication (unnecessary acknowledges removed) - Support of commands ReadMultipleParameter / WriteMultipleParameter - NodeID assignment by digital inputs supported (NodeId 241 and 242) - Minor corrections certification - ASnd frames with unknown ServiceID could disturb the BC (only possible with 3rd party MN) - Access to not existing objects in OD could cause firmware crash - When running X2X cycle times <200 us the X2X Bus was not working correctly (A&P 190630) - When in state PREOP_2 no SoC is received for 10sec the BC will fall back in PREOP_1 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(142) Version 1.0.0.0: ID: 190480 Support X67BC8331 Support X67BC8331, first version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(141) |
|||||
| Versión | Idioma | Sistema operativo | Fecha | Tamaño | Tipo | Descargar |
| 2.15.0.0 | * | 13.10.2022 | 2 MB | EXE | AS4_HW_X67BC8331.exe | |
| Descripción |
V4.0 HW Upgrade (X67BC8331) Revision information X67BC8331 Version 2.15.0.0: ID: 758850 Optimization of asynchronous register access Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(433), 1\42917_3.fw(433) Version 2.14.0.0: ID: 737340 NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 737345 POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438) POWERLINK Security Vulnerability (CVE-2020-13987) The POWERLINK IP stack was affected by a security vulnerability impacting thechecksum calculation of TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IP stack was affected by a security vulnerability impacting fragmented packet reassembly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 739455 Module documentation revised Data sheet V3.08 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(432), 1\42917_3.fw(432) Version 2.11.1.0: ID: 697885 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(430), 1\42917_3.fw(430) Version 2.11.0.0: ID: 664420 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665800 ModuleOk of IO module FALSE after warm restart even though the moduleis working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665880 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666165 Module documentation revised Data sheet V3.06 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(430), 1\42917_3.fw(430) Version 2.9.3.0: ID: 639730 / Support ID: 400268096 Alignment of AS output according to the FieldBusDesigner Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(427), 1\42917_3.fw(427) Version 2.9.0.0: ID: 629050 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629125 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629200 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629245 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(427), 1\42917_3.fw(427) Version 2.8.0.0: ID: 619240 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619270 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619650 / Support ID: 400268920 Firmwareupdate of X2XLink module at POWERLINK Stations does not work since H4.34 Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming. Problem occurs onBC and SL: X20BC0083 X20cBC0083 < HW-Upgrade 2.2.0.0 X20BC1083 X20cBC1083 < HW-Upgrade 2.5.0.0 X20BC8083 X20cBC8083 < HW-Upgrade 2.5.0.0 X20BC8084 X20cBC8084 < HW-Upgrade 2.5.0.0 X20SL8101 X20cSL8101 X67BC81RT.L12 < HW-Upgrade 2.5.0.0 X67BC8321-1 X67BC8331 X67BC8513.L12 Channel description changed: No Configuration description changed:No Firmware changed: No ID: 621720 / Support ID: 400264883 Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware:1\42917_1.fw(426), 1\42917_3.fw(426) Version 2.5.6.0: ID: 603859 APROL: missing attribute for channel-parameter with "Sig_*" inserted. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version 2.5.5.0: ID: 551155 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version 2.5.4.0: ID: 540355 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(419), 1\42917_3.fw(419) Version 2.5.2.0: ID: 493920 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(415), 1\42917_3.fw(415) Version 2.5.0.0: ID: 468210 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468215 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468220 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468580 CiRsupport Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(413), 1\42917_3.fw(413) Version 2.2.0.0: ID: 460145 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460265 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(411), 1\42917_3.fw(411) Version 2.1.0.0: ID: 439140 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439245 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(400), 1\42917_3.fw(400), 1\42917_5.fw(400) Version 2.0.0.0: ID: 390310 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(210), 1\42917_3.fw(210) Version 1.3.4.0: ID: 310880 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311045 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(168), 1\42917_3.fw(168) Version 1.3.3.0: ID: 305185 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(167), 1\42917_3.fw(167) Version 1.3.2.0: ID: 299005 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(165), 1\42917_3.fw(165) Version 1.3.1.0: ID: 289035 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(163), 1\42917_3.fw(163) Version 1.3.0.0: ID: 277195 Support of 'Multiple Asynchronous Send' Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 277765 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration descriptionchanged: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(160), 1\42917_3.fw(160) Version 1.2.0.0: ID: 246690 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X busof the BC - new objects: 20A3h and 2000h/9 - support for Simulationdevice added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(152),1\42917_3.fw(152) Version 1.0.8.0: ID: 218520 Extensionsand Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(145) Version 1.0.7.0: ID: 214450 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(144) Version 1.0.6.0: ID: 210945 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(143) Version 1.0.5.0: ID: 209765 Extensions and Bugfixes - New ASICS will be set to 3mA output current (A&P 182905) - Optimization of SDO communication (unnecessary acknowledges removed) - Support of commands ReadMultipleParameter / WriteMultipleParameter - NodeID assignment by digital inputs supported (NodeId 241 and 242) - Minor corrections certification - ASnd frames with unknown ServiceID could disturb the BC (only possible with 3rd party MN) - Access to notexisting objects in OD could cause firmware crash - When running X2X cycle times <200 us the X2X Bus was not working correctly (A&P 190630) - When in state PREOP_2 no SoC is received for 10sec the BC will fall back in PREOP_1 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(142) Version1.0.0.0: ID: 190480 Support X67BC8331 Support X67BC8331, first version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(141) |
|||||
| Versión | Idioma | Sistema operativo | Fecha | Tamaño | Tipo | Descargar |
| 2.14.0.0 | * | 25.10.2021 | 2 MB | EXE | AS4_HW_X67BC8331.exe | |
| Descripción |
V4.0 HW Upgrade (X67BC8331) Revision information X67BC8331 Version 2.14.0.0: ID: 737340 NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 737345 POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438) POWERLINK Security Vulnerability (CVE-2020-13987) The POWERLINK IP stack was affected by a security vulnerability impacting thechecksum calculation of TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IP stack was affected by a security vulnerability impacting fragmented packet reassembly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 739455 Module documentation revised Data sheet V3.08 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(432), 1\42917_3.fw(432) Version 2.11.1.0: ID: 697885 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(430), 1\42917_3.fw(430) Version 2.11.0.0: ID: 664420 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665800 ModuleOk ofIO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665880 Accessing non-cyclicregisters with AsIOAcc while ModuleOk = FALSE prevents module from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666165 Module documentation revised Data sheet V3.06 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(430), 1\42917_3.fw(430) Version 2.9.3.0: ID:639730 / Support ID: 400268096 Alignment of AS output according to the FieldBusDesigner Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(427),1\42917_3.fw(427) Version 2.9.0.0: ID: 629050 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629125 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629200 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629245 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(427), 1\42917_3.fw(427) Version2.8.0.0: ID: 619240 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619270 / Support ID: 400262159 Outputs of I/O modules behindthe bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619650 / Support ID: 400268920 Firmwareupdate of X2XLink module at POWERLINK Stations does not work since H4.34 Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming. Problem occurs on BC and SL: X20BC0083 X20cBC0083 < HW-Upgrade 2.2.0.0 X20BC1083 X20cBC1083 < HW-Upgrade 2.5.0.0 X20BC8083 X20cBC8083 < HW-Upgrade 2.5.0.0 X20BC8084 X20cBC8084 < HW-Upgrade 2.5.0.0 X20SL8101 X20cSL8101 X67BC81RT.L12 < HW-Upgrade 2.5.0.0 X67BC8321-1 X67BC8331 X67BC8513.L12 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 621720 / Support ID: 400264883 Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(426), 1\42917_3.fw(426) Version 2.5.6.0: ID: 603859 APROL: missing attribute for channel-parameter with "Sig_*" inserted. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version 2.5.5.0: ID: 551155 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version 2.5.4.0: ID: 540355 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(419), 1\42917_3.fw(419) Version 2.5.2.0: ID: 493920 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(415), 1\42917_3.fw(415) Version 2.5.0.0: ID: 468210 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468215 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468220 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468580 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(413), 1\42917_3.fw(413) Version 2.2.0.0: ID: 460145 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460265 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPUPowerCycle wenn SLXhinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(411), 1\42917_3.fw(411) Version 2.1.0.0: ID: 439140 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439245 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(400), 1\42917_3.fw(400), 1\42917_5.fw(400) Version 2.0.0.0: ID: 390310 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(210), 1\42917_3.fw(210) Version 1.3.4.0: ID: 310880 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FWupgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311045 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(168), 1\42917_3.fw(168) Version 1.3.3.0: ID: 305185 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on theCPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(167), 1\42917_3.fw(167) Version 1.3.2.0: ID: 299005 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(165), 1\42917_3.fw(165) Version 1.3.1.0: ID: 289035 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(163), 1\42917_3.fw(163) Version 1.3.0.0: ID: 277195 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277765 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(160), 1\42917_3.fw(160) Version 1.2.0.0: ID: 246690 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 - support for Simulation device added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(152), 1\42917_3.fw(152) Version 1.0.8.0: ID: 218520 Extensions and Bugfixes -Firmware-Version is transferred via IdentResponse in the first 4 bytes of thefield VendorSpecificExt1 - Support of PollResponse-Chaining Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(145) Version 1.0.7.0: ID: 214450 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(144) Version 1.0.6.0: ID: 210945 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(143) Version 1.0.5.0: ID: 209765 Extensions and Bugfixes - New ASICS will be set to 3mA output current (A&P 182905) - Optimization of SDO communication (unnecessary acknowledges removed) - Support of commands ReadMultipleParameter / WriteMultipleParameter - NodeID assignment by digital inputs supported (NodeId 241 and 242) - Minor corrections certification - ASnd frames with unknown ServiceID could disturb theBC (only possible with 3rd party MN) - Access to not existing objects inOD could cause firmware crash - When running X2X cycle times <200 us theX2X Bus was not working correctly(A&P 190630) - When in state PREOP_2 no SoC is received for 10sec the BC will fall back in PREOP_1 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(142) Version 1.0.0.0: ID: 190480 Support X67BC8331 Support X67BC8331, first version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(141) |
|||||
| Versión | Idioma | Sistema operativo | Fecha | Tamaño | Tipo | Descargar |
| 2.11.1.0 | * | 24.08.2020 | 2 MB | EXE | AS4_HW_X67BC8331.exe | |
| Descripción |
V4.0 HW Upgrade (X67BC8331) Revision information X67BC8331 Version 2.11.1.0: ID: 697885 Support for automatic DNA configurationfrom AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(430), 1\42917_3.fw(430) Version 2.11.0.0: ID: 664420 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665800 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665880 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666165 Module documentation revised Data sheet V3.06 Channel descriptionchanged: No Configuration description changed: No Firmware changed:No Firmware: 1\42917_1.fw(430), 1\42917_3.fw(430) Version 2.9.3.0: ID: 639730 / Support ID: 400268096 Alignment of AS output according to the FieldBusDesigner Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(427), 1\42917_3.fw(427) Version 2.9.0.0: ID: 629050 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629125 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629200 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629245 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(427), 1\42917_3.fw(427) Version 2.8.0.0: ID: 619240 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 619270 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619650 / Support ID: 400268920 Firmwareupdate of X2XLink module at POWERLINK Stations does not work since H4.34 Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming. Problem occurs on BC and SL: X20BC0083 X20cBC0083 < HW-Upgrade 2.2.0.0 X20BC1083 X20cBC1083 < HW-Upgrade 2.5.0.0 X20BC8083 X20cBC8083 < HW-Upgrade 2.5.0.0 X20BC8084 X20cBC8084 < HW-Upgrade 2.5.0.0 X20SL8101 X20cSL8101 X67BC81RT.L12 < HW-Upgrade 2.5.0.0 X67BC8321-1 X67BC8331 X67BC8513.L12 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 621720 / Support ID: 400264883 Display of further diagnostic data points in the I / O mapping of the X2X interfacefrom the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(426), 1\42917_3.fw(426) Version 2.5.6.0: ID: 603859 APROL: missing attribute for channel-parameter with "Sig_*" inserted. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version 2.5.5.0: ID: 551155 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version 2.5.4.0: ID: 540355 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(419), 1\42917_3.fw(419) Version 2.5.2.0: ID: 493920 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long timetakes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(415), 1\42917_3.fw(415) Version 2.5.0.0: ID: 468210 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468215 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468220 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468580 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(413), 1\42917_3.fw(413) Version 2.2.0.0: ID: 460145 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460265 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(411), 1\42917_3.fw(411) Version 2.1.0.0: ID: 439140 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439245 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\42917_1.fw(400), 1\42917_3.fw(400), 1\42917_5.fw(400) Version 2.0.0.0: ID: 390310 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\42917_1.fw(210), 1\42917_3.fw(210) Version 1.3.4.0: ID: 310880 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311045 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(168), 1\42917_3.fw(168) Version 1.3.3.0: ID: 305185 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(167), 1\42917_3.fw(167) Version 1.3.2.0: ID: 299005 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(165), 1\42917_3.fw(165) Version 1.3.1.0: ID: 289035 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(163), 1\42917_3.fw(163) Version 1.3.0.0: ID: 277195 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277765 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(160), 1\42917_3.fw(160) Version 1.2.0.0: ID: 246690 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 - support for Simulation device added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(152), 1\42917_3.fw(152) Version 1.0.8.0: ID: 218520 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\42917_1.fw(145) Version1.0.7.0: ID: 214450 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(144) Version 1.0.6.0: ID: 210945 Extensions and Bugfixes - Error correction for operationin Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(143) Version 1.0.5.0: ID: 209765 Extensions and Bugfixes - New ASICS will be set to 3mA output current (A&P 182905) - Optimization of SDO communication (unnecessary acknowledges removed) - Support of commands ReadMultipleParameter / WriteMultipleParameter - NodeID assignment by digital inputs supported (NodeId 241 and 242) -Minor corrections certification - ASnd frames with unknown ServiceID could disturb the BC (only possible with 3rd party MN) - Access to not existing objects in OD could cause firmware crash - When running X2X cycle times <200 us the X2X Bus was not working correctly (A&P 190630) - When in state PREOP_2 no SoC is received for 10sec the BC will fall back in PREOP_1 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(142) Version 1.0.0.0: ID: 190480 Support X67BC8331 Support X67BC8331, first version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(141) |
|||||
| Versión | Idioma | Sistema operativo | Fecha | Tamaño | Tipo | Descargar |
| 2.11.0.0 | * | 20.02.2020 | 2 MB | EXE | AS4_HW_X67BC8331.exe | |
| Descripción |
V4.0 HW Upgrade (X67BC8331) Revision information X67BC8331 Version 2.11.0.0: ID: 664420 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665800 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665880 Accessing non-cyclic registers withAsIOAcc while ModuleOk = FALSE prevents module from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666165 Module documentation revised Data sheet V3.06 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(430), 1\42917_3.fw(430) Version 2.9.3.0: ID: 639730 / Support ID: 400268096 Alignment of AS output according to the FieldBusDesigner Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(427), 1\42917_3.fw(427) Version 2.9.0.0: ID: 629050 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629125 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 629200 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629245 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(427), 1\42917_3.fw(427) Version 2.8.0.0: ID: 619240 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619270 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619650 / Support ID: 400268920 Firmwareupdate ofX2XLink module at POWERLINK Stations does not work since H4.34 Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming. Problem occurs on BC and SL: X20BC0083 X20cBC0083< HW-Upgrade 2.2.0.0 X20BC1083 X20cBC1083 < HW-Upgrade 2.5.0.0 X20BC8083 X20cBC8083 < HW-Upgrade 2.5.0.0 X20BC8084 X20cBC8084 < HW-Upgrade 2.5.0.0 X20SL8101 X20cSL8101 X67BC81RT.L12 < HW-Upgrade 2.5.0.0 X67BC8321-1 X67BC8331 X67BC8513.L12 Channel description changed:No Configuration description changed: No Firmware changed: No ID: 621720 / Support ID: 400264883 Display of further diagnostic datapoints in the I / O mapping of the X2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(426), 1\42917_3.fw(426) Version 2.5.6.0: ID: 603859 APROL: missing attribute for channel-parameter with "Sig_*" inserted. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version 2.5.5.0: ID: 551155 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version 2.5.4.0: ID: 540355 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(419), 1\42917_3.fw(419) Version 2.5.2.0: ID: 493920 / Support ID: 400103115, 400101850, 400154063, 400190752 FirstPOWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(415), 1\42917_3.fw(415) Version 2.5.0.0: ID: 468210 / Support ID: 400178654 Safety modulesin connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468215 optimization of X2XFW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468220 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468580 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(413), 1\42917_3.fw(413) Version 2.2.0.0: ID: 460145 / Support ID: 400168329 I/O modules behind POWERLINKbus controllers no longer achieving Operationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460265 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(411),1\42917_3.fw(411) Version 2.1.0.0: ID: 439140 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achievingOperationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439245 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(400), 1\42917_3.fw(400), 1\42917_5.fw(400) Version 2.0.0.0: ID: 390310 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(210), 1\42917_3.fw(210) Version 1.3.4.0: ID: 310880 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311045 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(168), 1\42917_3.fw(168) Version 1.3.3.0: ID: 305185 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(167), 1\42917_3.fw(167) Version 1.3.2.0: ID: 299005 / Support ID:400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(165), 1\42917_3.fw(165) Version 1.3.1.0: ID: 289035 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(163), 1\42917_3.fw(163) Version 1.3.0.0: ID: 277195 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277765 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(160), 1\42917_3.fw(160) Version 1.2.0.0: ID: 246690 DNA support; Update behavior on X2X bus of the BCimproved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 - support for Simulation device added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(152), 1\42917_3.fw(152) Version 1.0.8.0: ID: 218520 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(145) Version 1.0.7.0: ID: 214450 Extensions and Bugfixes - In systems with high X2X load it happenedthat IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(144) Version 1.0.6.0: ID: 210945 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(143) Version 1.0.5.0: ID: 209765 Extensions and Bugfixes - New ASICS will be set to 3mA output current (A&P 182905) - Optimization of SDO communication (unnecessary acknowledges removed) - Support of commands ReadMultipleParameter / WriteMultipleParameter - NodeID assignment by digital inputs supported (NodeId 241 and 242) - Minor corrections certification - ASnd frames with unknown ServiceID could disturb the BC (only possible with 3rd party MN) - Access to not existing objects in OD could causefirmware crash - When running X2X cycle times <200 us the X2X Bus was not working correctly (A&P 190630) - When in state PREOP_2 no SoC is received for 10sec the BC will fall back in PREOP_1 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(142) Version 1.0.0.0: ID: 190480 Support X67BC8331 Support X67BC8331, first version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(141) |
|||||
| Versión | Idioma | Sistema operativo | Fecha | Tamaño | Tipo | Descargar |
| 2.9.3.0 | * | 12.04.2019 | 2 MB | EXE | AS4_HW_X67BC8331.exe | |
| Descripción |
V4.0 HW Upgrade (X67BC8331) Revision information X67BC8331 Version 2.9.3.0: ID: 639730 / Support ID: 400268096 Alignment of AS output according to the FieldBusDesigner Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(427), 1\42917_3.fw(427) Version 2.9.0.0: ID: 629050 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629125 DNA: BC as head-end stationswitching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629200 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629245 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(427), 1\42917_3.fw(427) Version 2.8.0.0: ID: 619240 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619270 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 619650 / Support ID: 400268920 Firmwareupdate of X2XLink module at POWERLINK Stations does not work since H4.34 Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming. Problem occurs on BC and SL: X20BC0083 X20cBC0083 < HW-Upgrade 2.2.0.0 X20BC1083 X20cBC1083 < HW-Upgrade 2.5.0.0 X20BC8083 X20cBC8083 < HW-Upgrade 2.5.0.0 X20BC8084 X20cBC8084 < HW-Upgrade 2.5.0.0 X20SL8101 X20cSL8101 X67BC81RT.L12 < HW-Upgrade 2.5.0.0 X67BC8321-1 X67BC8331 X67BC8513.L12 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 621720 / Support ID: 400264883 Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(426), 1\42917_3.fw(426) Version 2.5.6.0: ID: 603859 APROL: missing attribute for channel-parameter with "Sig_*" inserted. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version 2.5.5.0: ID: 551155 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version 2.5.4.0: ID: 540355 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(419), 1\42917_3.fw(419) Version 2.5.2.0: ID: 493920 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(415), 1\42917_3.fw(415) Version 2.5.0.0: ID: 468210 / Support ID: 400178654 Safety modules in connection with PLK BCs, with onlyinput datapoints, are not initialized.by SL Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 468215 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468220 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468580 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(413), 1\42917_3.fw(413) Version 2.2.0.0: ID: 460145 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460265 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(411), 1\42917_3.fw(411) Version 2.1.0.0: ID: 439140 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 439245 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(400), 1\42917_3.fw(400), 1\42917_5.fw(400) Version 2.0.0.0: ID: 390310 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(210), 1\42917_3.fw(210) Version 1.3.4.0: ID: 310880 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311045 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(168), 1\42917_3.fw(168) Version 1.3.3.0: ID: 305185 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontrollerwas interrupted. Restarting the boscontroller restored communication. Loss ofasynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(167), 1\42917_3.fw(167) Version 1.3.2.0: ID: 299005 / Support ID: 400090781 Problem with FW-Updateof IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(165), 1\42917_3.fw(165) Version 1.3.1.0: ID: 289035 Certain X2X configurations don't work In very rare I/Oconstellations, the X2X modules don't start Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(163), 1\42917_3.fw(163) Version 1.3.0.0: ID: 277195 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277765 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(160), 1\42917_3.fw(160) Version 1.2.0.0: ID: 246690 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 - support for Simulation device added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(152), 1\42917_3.fw(152) Version 1.0.8.0: ID: 218520 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse inthe first 4 bytes of the field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(145) Version 1.0.7.0: ID: 214450 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(144) Version 1.0.6.0: ID: 210945 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(143) Version 1.0.5.0: ID: 209765 Extensions and Bugfixes - New ASICS will be set to 3mA output current (A&P 182905) - Optimization of SDO communication (unnecessary acknowledges removed) - Support of commands ReadMultipleParameter / WriteMultipleParameter - NodeID assignment by digital inputs supported (NodeId 241 and 242) - Minor corrections certification - ASnd frames with unknown ServiceID could disturb the BC (only possible with 3rd party MN) - Access to not existing objects in OD could cause firmware crash - When running X2X cycle times <200 us the X2X Bus was not working correctly (A&P 190630) - When in state PREOP_2 no SoC is received for 10sec the BC will fall back in PREOP_1 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(142) Version 1.0.0.0: ID: 190480 Support X67BC8331 Support X67BC8331, first version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(141) |
|||||
| Versión | Idioma | Sistema operativo | Fecha | Tamaño | Tipo | Descargar |
| 2.9.0.0 | * | 13.03.2019 | 2 MB | EXE | AS4_HW_X67BC8331.exe | |
| Descripción |
V4.0 HW Upgrade (X67BC8331) Revision information X67BC8331 Version 2.9.0.0: ID: 629050 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629125 DNA:BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629200 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629245 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(427), 1\42917_3.fw(427) Version 2.8.0.0: ID: 619240 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619270 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619650 / Support ID: 400268920 Firmwareupdate of X2XLink moduleat POWERLINK Stations does not work since H4.34 Since H4.34 the firmwareupdate of X2XLink modules connected to X67BC8321-1 did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming. Problem occurs on BC and SL: X20BC0083 X20cBC0083 < HW-Upgrade 2.2.0.0 X20BC1083 X20cBC1083 < HW-Upgrade 2.5.0.0 X20BC8083 X20cBC8083 < HW-Upgrade 2.5.0.0 X20BC8084 X20cBC8084 < HW-Upgrade 2.5.0.0 X20SL8101 X20cSL8101 X67BC81RT.L12 < HW-Upgrade 2.5.0.0 X67BC8321-1 X67BC8331 X67BC8513.L12 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 621720 / Support ID: 400264883 Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(426), 1\42917_3.fw(426) Version 2.5.6.0: ID: 603859 APROL: missing attribute for channel-parameter with "Sig_*" inserted. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version 2.5.5.0: ID: 551155 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version 2.5.4.0: ID: 540355 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(419), 1\42917_3.fw(419) Version 2.5.2.0: ID: 493920 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(415), 1\42917_3.fw(415) Version 2.5.0.0: ID: 468210 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468215 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468220 / Support ID: 400177243 X2XFW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468580 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(413), 1\42917_3.fw(413) Version 2.2.0.0: ID: 460145 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460265 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(411), 1\42917_3.fw(411) Version 2.1.0.0: ID: 439140 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439245 / Support ID: 400128436 I/O modules behind POWERLINK bus controllersno longer achieving Operationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(400), 1\42917_3.fw(400), 1\42917_5.fw(400) Version 2.0.0.0: ID: 390310 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(210), 1\42917_3.fw(210) Version 1.3.4.0: ID: 310880 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311045 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(168), 1\42917_3.fw(168) Version 1.3.3.0: ID: 305185 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restoredcommunication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(167), 1\42917_3.fw(167) Version 1.3.2.0: ID: 299005 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(165), 1\42917_3.fw(165) Version 1.3.1.0: ID: 289035 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(163), 1\42917_3.fw(163) Version 1.3.0.0: ID: 277195 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277765 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(160), 1\42917_3.fw(160) Version 1.2.0.0: ID: 246690 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules withbig FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 - support for Simulation device added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(152), 1\42917_3.fw(152) Version 1.0.8.0: ID: 218520 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(145) Version 1.0.7.0: ID: 214450 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(144) Version 1.0.6.0: ID: 210945 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(143) Version 1.0.5.0: ID: 209765 Extensions and Bugfixes - New ASICS will be set to 3mA output current (A&P 182905) - Optimization of SDO communication(unnecessary acknowledges removed) - Support of commands ReadMultipleParameter / WriteMultipleParameter - NodeID assignment by digital inputs supported (NodeId 241 and 242) - Minor corrections certification - ASndframes with unknown ServiceID could disturb the BC (only possible with 3rd party MN) - Access to not existing objects in OD could cause firmware crash - When running X2X cycle times <200 us the X2X Bus was not working correctly (A&P 190630) - When in state PREOP_2 no SoC is received for 10sec the BC will fall back in PREOP_1 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(142) Version 1.0.0.0: ID: 190480 Support X67BC8331 Support X67BC8331, first version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(141) |
|||||
| Versión | Idioma | Sistema operativo | Fecha | Tamaño | Tipo | Descargar |
| 2.8.0.0 | * | 12.12.2018 | 2 MB | EXE | AS4_HW_X67BC8331.exe | |
| Descripción |
V4.0 HW Upgrade (X67BC8331) Revision information X67BC8331 Version 2.8.0.0: ID: 619240 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619270 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619650 / Support ID: 400268920 Firmwareupdate of X2XLink module at POWERLINK Stations does not work since H4.34 Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming. Problem occurs on BC and SL: X20BC0083 X20cBC0083 < HW-Upgrade 2.2.0.0 X20BC1083 X20cBC1083 < HW-Upgrade 2.5.0.0 X20BC8083 X20cBC8083 < HW-Upgrade 2.5.0.0 X20BC8084 X20cBC8084 < HW-Upgrade 2.5.0.0 X20SL8101 X20cSL8101 X67BC81RT.L12 < HW-Upgrade 2.5.0.0 X67BC8321-1 X67BC8331 X67BC8513.L12 Channel description changed: No Configuration description changed: No Firmwarechanged: No ID: 621720 / Support ID: 400264883 Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(426), 1\42917_3.fw(426) Version 2.5.6.0: ID: 603859 APROL: missing attribute for channel-parameter with "Sig_*" inserted. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version2.5.5.0: ID: 551155 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version 2.5.4.0: ID: 540355 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(419), 1\42917_3.fw(419) Version 2.5.2.0: ID: 493920 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(415), 1\42917_3.fw(415) Version 2.5.0.0: ID: 468210 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, arenot initialized.by SL Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 468215 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468220/ Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468580 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(413), 1\42917_3.fw(413) Version 2.2.0.0: ID: 460145 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460265 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(411), 1\42917_3.fw(411) Version 2.1.0.0: ID: 439140 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439245 / Support ID: 400128436 I/O modulesbehind POWERLINK bus controllers no longer achieving Operationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(400), 1\42917_3.fw(400), 1\42917_5.fw(400) Version 2.0.0.0: ID: 390310 / Support ID: 400129274 Uncommon X2X settings cause permanentboot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(210), 1\42917_3.fw(210) Version 1.3.4.0: ID: 310880 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311045 / Support ID:400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(168), 1\42917_3.fw(168) Version 1.3.3.0: ID: 305185 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(167), 1\42917_3.fw(167) Version 1.3.2.0: ID: 299005 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(165), 1\42917_3.fw(165) Version 1.3.1.0: ID: 289035 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(163), 1\42917_3.fw(163) Version 1.3.0.0: ID: 277195 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:277765 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(160), 1\42917_3.fw(160) Version 1.2.0.0: ID: 246690 DNA support; Update behavior onX2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC -new objects: 20A3h and 2000h/9 - support for Simulation device added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(152), 1\42917_3.fw(152) Version 1.0.8.0: ID: 218520 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(145) Version 1.0.7.0: ID: 214450 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(144) Version 1.0.6.0: ID: 210945 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(143) Version 1.0.5.0: ID: 209765 Extensions and Bugfixes - New ASICS will be set to 3mA output current (A&P 182905) - Optimization of SDO communication (unnecessary acknowledges removed) - Support of commands ReadMultipleParameter / WriteMultipleParameter - NodeIDassignment by digital inputs supported (NodeId 241 and 242) - Minor corrections certification - ASnd frames with unknown ServiceID could disturb the BC (only possible with 3rd party MN) - Access to not existing objectsin OD could cause firmware crash - When running X2X cycle times <200 us the X2X Bus was not working correctly (A&P 190630) - When in state PREOP_2 no SoC is received for 10sec the BC will fall back in PREOP_1 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(142) Version 1.0.0.0: ID: 190480 Support X67BC8331 Support X67BC8331, first version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(141) |
|||||
| Versión | Idioma | Sistema operativo | Fecha | Tamaño | Tipo | Descargar |
| 2.5.6.0 | * | 23.07.2018 | 2 MB | EXE | AS4_HW_X67BC8331.exe | |
| Descripción |
V4.0 HW Upgrade (X67BC8331) Revision information X67BC8331 Version 2.5.6.0: ID: 603859 APROL: missing attribute for channel-parameter with "Sig_*" inserted. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version 2.5.5.0: ID: 551155 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version 2.5.4.0: ID: 540355 /Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(419), 1\42917_3.fw(419) Version 2.5.2.0: ID: 493920 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDPASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(415), 1\42917_3.fw(415) Version 2.5.0.0: ID: 468210 / Support ID: 400178654 Safety modules in connectionwith PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468215 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468220 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468580 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(413), 1\42917_3.fw(413) Version 2.2.0.0: ID: 460145 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460265 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\42917_1.fw(411), 1\42917_3.fw(411) Version 2.1.0.0: ID: 439140 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439245 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(400), 1\42917_3.fw(400), 1\42917_5.fw(400) Version 2.0.0.0: ID: 390310 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(210), 1\42917_3.fw(210) Version 1.3.4.0: ID: 310880 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311045 / Support ID: 400051206 Expansion: Link-selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(168), 1\42917_3.fw(168) Version 1.3.3.0: ID: 305185 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(167), 1\42917_3.fw(167) Version 1.3.2.0: ID: 299005 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(165), 1\42917_3.fw(165) Version 1.3.1.0: ID: 289035 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(163), 1\42917_3.fw(163) Version 1.3.0.0: ID: 277195 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277765 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(160), 1\42917_3.fw(160) Version 1.2.0.0: ID: 246690 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 - support for Simulation device added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(152), 1\42917_3.fw(152) Version 1.0.8.0: ID: 218520 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(145) Version 1.0.7.0: ID: 214450 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(144) Version 1.0.6.0: ID: 210945 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(143) Version 1.0.5.0: ID: 209765 Extensions and Bugfixes - New ASICS will be set to 3mA output current (A&P 182905) - Optimization of SDO communication (unnecessary acknowledges removed) - Support of commands ReadMultipleParameter / WriteMultipleParameter - NodeID assignment by digital inputs supported (NodeId 241 and 242) - Minor corrections certification - ASnd frames with unknown ServiceID could disturb the BC (only possible with 3rd party MN) - Access to not existing objects in OD could cause firmware crash - When running X2X cycle times <200 us the X2X Bus was not working correctly (A&P 190630) - When in state PREOP_2 no SoC is received for 10sec the BC will fall back in PREOP_1 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(142) Version 1.0.0.0: ID: 190480 Support X67BC8331 Support X67BC8331, first version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(141) |
|||||
| Versión | Idioma | Sistema operativo | Fecha | Tamaño | Tipo | Descargar |
| 2.5.5.0 | * | 08.09.2017 | 2 MB | EXE | AS4_HW_X67BC8331.exe | |
| Descripción |
V4.0 HW Upgrade (X67BC8331) Revision information X67BC8331 Version 2.5.5.0: ID: 551155 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(421), 1\42917_3.fw(421) Version 2.5.4.0: ID: 540355 / Support ID: 400202320 BC sporadicallynot going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\42917_1.fw(419), 1\42917_3.fw(419) Version 2.5.2.0: ID: 493920 / Support ID: 400103115, 400101850, 400154063,400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(415), 1\42917_3.fw(415) Version 2.5.0.0: ID: 468210 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468215 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468220 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468580 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(413), 1\42917_3.fw(413) Version 2.2.0.0: ID: 460145 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460265 /Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(411), 1\42917_3.fw(411) Version 2.1.0.0: ID: 439140 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439245 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(400), 1\42917_3.fw(400), 1\42917_5.fw(400) Version 2.0.0.0: ID: 390310 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(210), 1\42917_3.fw(210) Version 1.3.4.0: ID: 310880 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINKV1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311045 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\42917_1.fw(168), 1\42917_3.fw(168) Version 1.3.3.0: ID: 305185 / Support ID: 400094368 ACOPOSmultiwith SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(167), 1\42917_3.fw(167) Version 1.3.2.0: ID:299005 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(165), 1\42917_3.fw(165) Version 1.3.1.0: ID: 289035 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(163), 1\42917_3.fw(163) Version 1.3.0.0: ID: 277195 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277765 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(160), 1\42917_3.fw(160) Version 1.2.0.0: ID: 246690 DNA support; Update behavioron X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 - support for Simulation device added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42917_1.fw(152), 1\42917_3.fw(152) Version 1.0.8.0: ID: 218520 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(145) Version 1.0.7.0: ID: 214450 Extensions and Bugfixes - In systems with highX2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 1\42917_1.fw(144) Version 1.0.6.0: ID: 210945 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42917_1.fw(143) Version 1.0.5.0: ID: 209765 Extensions andBugfixes - New ASICS will be set to 3mA output current (A&P 182905) - Optimization of SDO communication (unnecessary acknowledges removed) -Support of commands ReadMultipleParameter / WriteMultipleParameter - NodeID assignment by digital inputs supported (NodeId 241 and 242) - Minor corrections certification - ASnd frames with unknown ServiceID could disturb the BC (only possible with 3rd party MN) - Access to not existing objects in OD could cause firmware crash - When running X2X cycle times <200 us the X2X Bus was not working correctly (A&P 190630) - When in state PREOP_2 no SoC is received for 10sec the BC will fall back in PREOP_1 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(142) Version 1.0.0.0: ID: 190480 Support X67BC8331 Support X67BC8331, first version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42917_1.fw(141) |
|||||