DWL@DWL10000317899
| Versión | Idioma | Sistema operativo | Fecha | Tamaño | Tipo | Descargar |
|---|---|---|---|---|---|---|
| 1.4.0.0 | * | 23.02.2023 | 1,018 KB | EXE | AS4_HW_X20DI2371.exe | |
| Descripción |
V4.0 HW Upgrade (X20DI2371) Revision information X20DI2371 Version 1.4.0.0: ID: 765990 Setting "Allow unbalanced on/off variable" can result in a cyclic failure of the module starting with revision F1. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 765995 Failure ModulOK If this module starting with revision F1 is operated behind a bus controller, the network status fails every 10 s (for one X2X cycle). This failure has the following effects. - Local X2X bus: No effect - POWERLINK / Modbus TCP / PROFIBUS / CAN I/O: No effect - CANopen: "Object 0x30B2 Network status OK" failssporadically. - OPC-UA: Flag ModuleOK of the respective X2X module may fail sporadically - EthernetIP / PROFINET / Sercos3 / EtherCAT: - No effectdirectly on the bus controller. - The network status is transferred as BYTE at the beginning of the cyclicdata of the respective X2X station (ModuleOK) and can be evaluated by the respective remote station (data point mapping and evaluation within the application). - Setpoint: 0xF5, in the event of error: 0xF1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7053_1.fw(560), 1\7053_20.fw(230), 1\7053_22.fw(230), 1\7053_5.fw(800) Version 1.3.0.0: ID: 748985 Support new HW variant 20 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7053_1.fw(560), 1\7053_20.fw(220), 1\7053_5.fw(800) Version 1.2.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.1.1: ID: 405695 Enhancements packed data point for inputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7053_1.fw(560), 1\7053_5.fw(800) Version 1.0.1.0: ID: 217385 Adaptation UART Re-Init Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7053_1.fw(560), 1\7053_5.fw(800) |
|||||
| Versión | Idioma | Sistema operativo | Fecha | Tamaño | Tipo | Descargar |
| 1.3.0.0 | * | 19.08.2022 | 758 KB | EXE | AS4_HW_X20DI2371.exe | |
| Descripción |
V4.0 HW Upgrade (X20DI2371) Revision information X20DI2371 Version 1.3.0.0: ID: 748985 Support new HW variant 20 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7053_1.fw(560), 1\7053_20.fw(220), 1\7053_5.fw(800) Version 1.2.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.1.1: ID: 405695 Enhancements packed data point for inputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7053_1.fw(560), 1\7053_5.fw(800) Version 1.0.1.0: ID: 217385 Adaptation UART Re-Init Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\7053_1.fw(560), 1\7053_5.fw(800) |
|||||
| Versión | Idioma | Sistema operativo | Fecha | Tamaño | Tipo | Descargar |
| 1.2.0.0 | * | 23.07.2021 | 537 KB | EXE | AS4_HW_X20DI2371.exe | |
| Descripción |
V4.0 HW Upgrade (X20DI2371) Revision information X20DI2371 Version 1.2.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.1.1: ID: 405695 Enhancements packed data point for inputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7053_1.fw(560), 1\7053_5.fw(800) Version 1.0.1.0: ID: 217385 Adaptation UART Re-Init Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\7053_1.fw(560), 1\7053_5.fw(800) |
|||||
| Versión | Idioma | Sistema operativo | Fecha | Tamaño | Tipo | Descargar |
| 1.1.0.0 | * | 25.10.2019 | 533 KB | EXE | AS4_HW_X20DI2371.exe | |
| Descripción |
V4.0 HW Upgrade (X20DI2371) Revision information X20DI2371 Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.1.1: ID: 405695 Enhancements packed data point for inputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7053_1.fw(560), 1\7053_5.fw(800) Version 1.0.1.0: ID: 217385 Adaptation UART Re-Init Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7053_1.fw(560), 1\7053_5.fw(800) |
|||||
| Versión | Idioma | Sistema operativo | Fecha | Tamaño | Tipo | Descargar |
| 1.0.1.1 | * | 11.12.2014 | 554 KB | EXE | AS4_HW_X20DI2371.exe | |
| Descripción |
V4.0 HW Upgrade (X20DI2371) Revision information X20DI2371 Version 1.0.1.1: ID: 405695 Enhancements packed data point for inputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7053_1.fw(560), 1\7053_5.fw(800) Version 1.0.1.0: ID: 217385 Adaptation UART Re-Init Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7053_1.fw(560), 1\7053_5.fw(800) |
|||||