V4.0 HW Upgrade (5PC901.TS77-08)

DWL@DWL10000307256

Versión Idioma
Sistema operativo
Fecha
Tamaño
Tipo Descargar
1.2.3.0 * 15.11.2022 578 KB EXE AS4_HW_5PC901.TS77-08.exe
Descripción V4.0 HW Upgrade (5PC901.TS77-08)

Revision information 5PC901.TS77-08

Version 1.2.3.0:

ID: 759355
New MTCX FW V01.32 for PPC900
New MTCX FW V01.32 for PPC900 with following changes:
- Optimized internal power supply.
- Bugfix: 5AC901.ICAN-01 (SJA1000 CAN).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(132)

Version 1.2.2.0:

ID: 675960
Wear level of storage medium from AR A4.90
Additional data point to display the wear level in %.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 695780
New MTCX FW V01.31 for PPC900
New MTCX FW V01.31 for PPC900 with following changes:
- Optimization of the SDL interface in combination with DVI panels.
- Bugfix: 5AC901.ISIO-00 did not work in IF-Slot1. The5AC901.ISIO-00 worked without any problems in IF-Slot2.
This problem only affects MTCX version V01.27.
- Bugfix: internal UPS is now also loaded instandby.
This problem only affects MTCX version V01.27.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(131)

Version 1.2.1.0:

ID: 674210
New MTCX FW V01.27 for PPC900
New MTCX FW V01.27 for PPC900 with following changes:
- Optimized internal keyboard syncronization.
- Optimized internal power supply syncronization.
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes

ID: 674230
EPLAN Daten implemented
Channel descriptionchanged: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\57294_0.fw(127)

Version 1.2.0.0:

ID: 607160
New MTCX FW V01.26 for PPC900
New MTCX FW V01.26 for PPC900 withfollowing changes:
- Support for IF option 5AC901.I232-00 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(126)

Version 1.1.9.0:

ID: 567905
New MTCX FW V01.25 for PPC900
New MTCX FW V01.25 for PPC900 with following changes:
- Support for B&R Hypervisor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(125)

Version 1.1.8.0:

ID: 552050
Bugfix for VC4 internal datapoints
The internal data points of VC4 and illuminated ring keys are working againfrom Automation Runtime embedded A4.33 on.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57294_0.fw(124)

Version 1.1.7.0:

ID: 507825
Serial number for 5PPC2100 and 5PC901 read incorrectly by function block and SDM
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 533575
New MTCX FW V01.24 for PPC900
New MTCX FW V01.24 for PPC900 with following changes:
- Support for IF option 5AC901.ICAN-01.
- Support syncronization byte for BRADI interface over several OS systems.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(124)

Version 1.1.6.0:

ID: 487380
New MTCX FW V01.23 for PPC900
New MTCX FW V01.23 for PPC900 with following changes:
- Bugfix: sporadical verify problems during a FW upgrade on a Automation Panel connected with SDL. The problem is actually only seen with long SDL cables starting with 20m.
- Optimization of the Suspend/Resume function for USB devices connected withSDL-Link.
- Support for AP5000 Key Extensions.
- Optimization of the maximum inrush current at minimum input voltage of thePPC900 system.
- Bugfix: "Thermal Runaway" effect of the 5AC901.BUPS-xx battery units.
- Optimized SDL equalizer settings.
- Bugfix: with operating temperatures under 5°C, there are sporadic problemsduring the SDL connection establishment using the SDL cable with extender (5CASDL.0xx0-13).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(123)

Version 1.1.5.0:

ID: 438325
New MTCX FW V01.19 for PPC900
New MTCX FW V01.19 for PPC900 with following changes:
- Optimized internal memory handling for the MTCX processor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(119)

Version 1.1.4.0:

ID: 434840
New MTCX FW V01.18 for PPC900
New MTCX FW V01.18 for PPC900 with following changes:
- Support for Panels with external backlight LED driver (e.g.: AP1000).
- Bugfix: if a 5AC901.IUPS-xx (internal UPS) is used without a 5AC901.BUPS-xx (battery unit) under AR, no NMI was generated in a PowerFail case.
With normal UPS operation (with connected battery unit) this problem does not occur.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 436125
Bugfix for Modbus TCP with ARwin
From Automation Studio version 4.1 and ARwin version G4.10 on the PPC900 can beused as Modbus TCP slave.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57294_0.fw(118)

Version 1.1.2.0:

ID: 415710
MTCX Upgrade to version V01.17
New MTCX FW V01.17 with following changes:
- Bugfix: sporadic problem with jumping cursor on Intelli touchscreens (customized systems).
- Support: FW upgrade for the external SDL3 converter box (5COSD3.1000-00).
- Optimized measurement interval for the internal temperature sensors.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(117)

Version 1.1.1.0:

ID: 397075
MTCX Upgrade to version V01.15
MTCX V01.14 to V01.15
- Support for IF option 5AC901.ISIO-00.
- Bugfix: negative CPU temperature.
MTCX V01.13 to V01.14
- Support for bus unit 5AC902.BX02-02.
- Optimization PS in standby mode.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(115)

Version 1.1.0.1:

ID: 376365
AS4.x: Ethernet I/O Mapping added

New MTCX version V1.13
AS4.x: WhenModbus is activated, the corresponding data points are availablein Automation Studio.
MTCX:
-Power supply change because of Clampdiods.
-Power supply change for Ready Relay Module (5V, 3V3 OFF in standby).
-Improved error handling when display addressing.
-Workaraund for batteries, which become too hot.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(113)

Version 1.1.0.0:

ID: 373200
Support for 5PC901.TS77-08
The CPU board for Panel PC 900 is supported with Automation Studio V4.0.17.x.
In addition, the minimum version H4.06 or F4.08 of Automation Runtime must beused.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\57294_0.fw(109)
Versión Idioma
Sistema operativo
Fecha
Tamaño
Tipo Descargar
1.2.2.0 * 20.11.2020 581 KB EXE AS4_HW_5PC901.TS77-08.exe
Descripción V4.0 HW Upgrade (5PC901.TS77-08)

Revision information 5PC901.TS77-08

Version 1.2.2.0:

ID: 675960
Wear level of storage medium from AR A4.90
Additional data point to display the wear level in %.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 695780
New MTCX FW V01.31 for PPC900
New MTCX FW V01.31 for PPC900 with following changes:
- Optimization of the SDL interface in combination with DVI panels.
- Bugfix: 5AC901.ISIO-00 did not work in IF-Slot1. The 5AC901.ISIO-00 worked without any problems in IF-Slot2.
This problem only affects MTCX version V01.27.
- Bugfix: internal UPS is now also loaded in standby.
This problem only affects MTCX version V01.27.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(131)

Version 1.2.1.0:

ID: 674210
New MTCX FW V01.27 for PPC900
New MTCX FW V01.27 for PPC900 with following changes:
- Optimized internal keyboard syncronization.
- Optimized internal power supply syncronization.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 674230
EPLAN Daten implemented
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\57294_0.fw(127)

Version 1.2.0.0:

ID: 607160
New MTCX FW V01.26 for PPC900
NewMTCX FW V01.26 for PPC900 with following changes:
- Support for IF option5AC901.I232-00 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(126)

Version 1.1.9.0:

ID: 567905
New MTCX FW V01.25 for PPC900
New MTCX FW V01.25 for PPC900 with following changes:
-Support for B&R Hypervisor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(125)

Version 1.1.8.0:

ID: 552050
Bugfix for VC4 internal datapoints
The internal data points of VC4 and illuminated ring keys are working againfrom Automation Runtime embedded A4.33 on.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57294_0.fw(124)

Version 1.1.7.0:

ID: 507825
Serial number for 5PPC2100 and 5PC901 read incorrectly by function block and SDM
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 533575
NewMTCX FW V01.24 for PPC900
New MTCX FW V01.24 for PPC900 with following changes:
- Support for IF option 5AC901.ICAN-01.
- Support syncronization byte for BRADI interface over several OS systems.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(124)

Version 1.1.6.0:

ID: 487380
New MTCX FW V01.23 for PPC900
New MTCX FW V01.23 for PPC900 with following changes:
- Bugfix: sporadical verify problems during a FW upgrade on a Automation Panel connected with SDL. The problem is actually only seen with long SDL cables starting with 20m.
- Optimization of the Suspend/Resume function for USB devices connected withSDL-Link.
- Support for AP5000Key Extensions.
- Optimization of the maximum inrush current at minimum input voltage of thePPC900 system.
- Bugfix: "Thermal Runaway" effect of the 5AC901.BUPS-xx battery units.
- Optimized SDL equalizer settings.
- Bugfix: with operating temperatures under 5°C, there are sporadic problemsduring the SDL connection establishment using the SDL cable with extender (5CASDL.0xx0-13).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(123)

Version 1.1.5.0:

ID: 438325
New MTCX FW V01.19 for PPC900
New MTCX FW V01.19 for PPC900 with following changes:
- Optimized internal memory handling for the MTCX processor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(119)

Version 1.1.4.0:

ID: 434840
New MTCX FW V01.18 for PPC900
New MTCX FW V01.18 for PPC900 with followingchanges:
- Support for Panels with external backlight LED driver (e.g.: AP1000).
- Bugfix: if a 5AC901.IUPS-xx (internal UPS) is used without a 5AC901.BUPS-xx (battery unit) under AR, no NMI was generated in a PowerFail case.
With normal UPS operation (with connected battery unit) this problem does not occur.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 436125
Bugfix for Modbus TCP with ARwin
From Automation Studio version 4.1 and ARwin version G4.10 on the PPC900 can be used as Modbus TCP slave.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57294_0.fw(118)

Version 1.1.2.0:

ID: 415710
MTCX Upgrade to version V01.17
New MTCX FW V01.17 with following changes:
- Bugfix: sporadic problem with jumping cursor on Intelli touchscreens (customized systems).
- Support: FW upgrade for the external SDL3 converter box (5COSD3.1000-00).
- Optimized measurement interval for theinternal temperature sensors.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(117)

Version 1.1.1.0:

ID: 397075
MTCX Upgrade to version V01.15
MTCX V01.14 to V01.15
- Support for IF option 5AC901.ISIO-00.
- Bugfix: negative CPU temperature.
MTCX V01.13 to V01.14
- Support for bus unit 5AC902.BX02-02.
- Optimization PS in standby mode.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(115)

Version 1.1.0.1:

ID: 376365
AS4.x: Ethernet I/O Mapping added

New MTCXversion V1.13
AS4.x: When Modbus is activated, the corresponding data points are available in Automation Studio.
MTCX:
-Power supply change because of Clampdiods.
-Power supply change for Ready Relay Module (5V, 3V3 OFFin standby).
-Improved error handling when display addressing.
-Workaraund for batteries, which become too hot.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(113)

Version 1.1.0.0:

ID: 373200
Support for 5PC901.TS77-08
The CPU board for Panel PC 900 is supported withAutomation Studio V4.0.17.x.
In addition, the minimum version H4.06 or F4.08 of Automation Runtime must beused.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\57294_0.fw(109)
Versión Idioma
Sistema operativo
Fecha
Tamaño
Tipo Descargar
1.2.1.0 * 07.02.2020 572 KB EXE AS4_HW_5PC901.TS77-08.exe
Descripción V4.0 HW Upgrade (5PC901.TS77-08)

Revision information 5PC901.TS77-08

Version 1.2.1.0:

ID: 674210
New MTCX FW V01.27 for PPC900
New MTCX FW V01.27 for PPC900 with following changes:
- Optimized internal keyboard syncronization.
- Optimized internal power supply syncronization.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 674230
EPLAN Daten implemented
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\57294_0.fw(127)

Version 1.2.0.0:

ID: 607160
New MTCX FW V01.26 for PPC900
NewMTCX FW V01.26 for PPC900 with following changes:
- Support for IF option5AC901.I232-00 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(126)

Version 1.1.9.0:

ID: 567905
New MTCX FW V01.25 for PPC900
New MTCX FW V01.25 for PPC900 with following changes:
-Support for B&R Hypervisor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(125)

Version 1.1.8.0:

ID: 552050
Bugfix for VC4 internal datapoints
The internal data points of VC4 and illuminated ring keys are working againfrom Automation Runtime embedded A4.33 on.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57294_0.fw(124)

Version 1.1.7.0:

ID: 507825
Serial number for 5PPC2100 and 5PC901 read incorrectly by function block and SDM
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 533575
NewMTCX FW V01.24 for PPC900
New MTCX FW V01.24 for PPC900 with following changes:
- Support for IF option 5AC901.ICAN-01.
- Support syncronization byte for BRADI interface over several OS systems.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(124)

Version 1.1.6.0:

ID: 487380
New MTCX FW V01.23 for PPC900
New MTCX FW V01.23 for PPC900 with following changes:
- Bugfix: sporadical verify problems during a FW upgrade on a Automation Panel connected with SDL. The problem is actually only seen with long SDL cables starting with 20m.
- Optimization of the Suspend/Resume function for USB devices connected withSDL-Link.
- Support for AP5000Key Extensions.
- Optimization of the maximum inrush current at minimum input voltage of thePPC900 system.
- Bugfix: "Thermal Runaway" effect of the 5AC901.BUPS-xx battery units.
- Optimized SDL equalizer settings.
- Bugfix: with operating temperatures under 5°C, there are sporadic problemsduring the SDL connection establishment using the SDL cable with extender (5CASDL.0xx0-13).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(123)

Version 1.1.5.0:

ID: 438325
New MTCX FW V01.19 for PPC900
New MTCX FW V01.19 for PPC900 with following changes:
- Optimized internal memory handling for the MTCX processor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(119)

Version 1.1.4.0:

ID: 434840
New MTCX FW V01.18 for PPC900
New MTCX FW V01.18 for PPC900 with followingchanges:
- Support for Panels with external backlight LED driver (e.g.: AP1000).
- Bugfix: if a 5AC901.IUPS-xx (internal UPS) is used without a 5AC901.BUPS-xx (battery unit) under AR, no NMI was generated in a PowerFail case.
With normal UPS operation (with connected battery unit) this problem does not occur.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 436125
Bugfix for Modbus TCP with ARwin
From Automation Studio version 4.1 and ARwin version G4.10 on the PPC900 can be used as Modbus TCP slave.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57294_0.fw(118)

Version 1.1.2.0:

ID: 415710
MTCX Upgrade to version V01.17
New MTCX FW V01.17 with following changes:
- Bugfix: sporadic problem with jumping cursor on Intelli touchscreens (customized systems).
- Support: FW upgrade for the external SDL3 converter box (5COSD3.1000-00).
- Optimized measurement interval for theinternal temperature sensors.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(117)

Version 1.1.1.0:

ID: 397075
MTCX Upgrade to version V01.15
MTCX V01.14 to V01.15
- Support for IF option 5AC901.ISIO-00.
- Bugfix: negative CPU temperature.
MTCX V01.13 to V01.14
- Support for bus unit 5AC902.BX02-02.
- Optimization PS in standby mode.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(115)

Version 1.1.0.1:

ID: 376365
AS4.x: Ethernet I/O Mapping added

New MTCXversion V1.13
AS4.x: When Modbus is activated, the corresponding data points are available in Automation Studio.
MTCX:
-Power supply change because of Clampdiods.
-Power supply change for Ready Relay Module (5V, 3V3 OFFin standby).
-Improved error handling when display addressing.
-Workaraund for batteries, which become too hot.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(113)

Version 1.1.0.0:

ID: 373200
Support for 5PC901.TS77-08
The CPU board for Panel PC 900 is supported withAutomation Studio V4.0.17.x.
In addition, the minimum version H4.06 or F4.08 of Automation Runtime must beused.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\57294_0.fw(109)
Versión Idioma
Sistema operativo
Fecha
Tamaño
Tipo Descargar
1.2.0.0 * 26.09.2018 904 KB EXE AS4_HW_5PC901.TS77-08.exe
Descripción V4.0 HW Upgrade (5PC901.TS77-08)

Revision information 5PC901.TS77-08

Version 1.2.0.0:

ID: 607160
New MTCX FW V01.26 for PPC900
New MTCX FW V01.26 for PPC900 with following changes:
- Support for IF option 5AC901.I232-00 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(126)

Version 1.1.9.0:

ID: 567905
New MTCXFW V01.25 for PPC900
New MTCX FW V01.25 for PPC900 with following changes:
- Support for B&R Hypervisor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(125)

Version 1.1.8.0:

ID: 552050
Bugfix for VC4 internal datapoints
The internal data points of VC4 and illuminated ring keys are working againfrom Automation Runtime embedded A4.33 on.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57294_0.fw(124)

Version 1.1.7.0:

ID: 507825
Serial number for 5PPC2100 and 5PC901 read incorrectly by function block and SDM
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 533575
New MTCX FW V01.24 for PPC900
New MTCX FW V01.24 for PPC900 with following changes:
- Support for IF option 5AC901.ICAN-01.
- Support syncronization byte for BRADI interface over several OS systems.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(124)

Version 1.1.6.0:

ID: 487380
New MTCX FW V01.23 for PPC900
New MTCX FW V01.23 for PPC900 with following changes:
- Bugfix: sporadical verify problems during a FW upgrade on a Automation Panel connected with SDL. The problem is actually only seen with long SDL cables starting with 20m.
- Optimization of the Suspend/Resume function for USB devices connected withSDL-Link.
- Support for AP5000 Key Extensions.
- Optimization of the maximum inrush current at minimum input voltage of thePPC900 system.
- Bugfix: "Thermal Runaway" effect of the 5AC901.BUPS-xx battery units.
- Optimized SDL equalizer settings.
- Bugfix: with operating temperatures under 5°C, there are sporadic problemsduring the SDL connection establishment using the SDL cable with extender (5CASDL.0xx0-13).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(123)

Version 1.1.5.0:

ID: 438325
New MTCX FW V01.19 for PPC900
New MTCX FW V01.19 for PPC900 with following changes:
- Optimized internal memory handling for the MTCX processor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(119)

Version 1.1.4.0:

ID: 434840
New MTCX FW V01.18 for PPC900
New MTCX FW V01.18 for PPC900 with following changes:
- Support for Panels with external backlight LED driver (e.g.: AP1000).
- Bugfix: if a 5AC901.IUPS-xx (internal UPS) is used without a 5AC901.BUPS-xx (battery unit) under AR, no NMI was generated in a PowerFail case.
With normal UPS operation (with connected battery unit) this problem does not occur.
Channel description changed: No
Configurationdescription changed: No
Firmware changed: Yes

ID: 436125
Bugfix for Modbus TCP with ARwin
From Automation Studio version 4.1 and ARwin version G4.10 on the PPC900 can be used as Modbus TCP slave.
Channeldescription changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57294_0.fw(118)

Version 1.1.2.0:

ID: 415710
MTCX Upgrade to version V01.17
New MTCX FW V01.17 with following changes:
- Bugfix: sporadic problem with jumping cursor on Intelli touchscreens (customized systems).
- Support: FW upgrade for the external SDL3 converter box (5COSD3.1000-00).
- Optimized measurement intervalfor the internal temperature sensors.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(117)

Version 1.1.1.0:

ID: 397075
MTCX Upgrade to version V01.15
MTCX V01.14 to V01.15
- Support for IF option 5AC901.ISIO-00.
- Bugfix: negative CPU temperature.
MTCX V01.13 to V01.14
- Support for bus unit 5AC902.BX02-02.
- Optimization PS in standby mode.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(115)

Version 1.1.0.1:

ID: 376365
AS4.x: Ethernet I/O Mapping added

New MTCX version V1.13
AS4.x: When Modbus is activated, the correspondingdata points are availablein Automation Studio.
MTCX:
-Power supply change because of Clampdiods.
-Power supply change for Ready Relay Module (5V,3V3 OFF in standby).
-Improved error handling when display addressing.
-Workaraund for batteries, which become too hot.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57294_0.fw(113)

Version 1.1.0.0:

ID: 373200
Support for 5PC901.TS77-08
The CPU board for Panel PC 900 is supported with Automation Studio V4.0.17.x.
In addition, the minimum version H4.06 or F4.08 of Automation Runtime must beused.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\57294_0.fw(109)
Versión Idioma
Sistema operativo
Fecha
Tamaño
Tipo Descargar
1.1.9.0 * 21.12.2017 960 KB EXE AS4_HW_5PC901.TS77-08.exe
Descripción V4.0 HW Upgrade (5PC901.TS77-08)

Revision information 5PC901.TS77-00

Version 1.1.9.0:

ID: 567905
New MTCX FW V01.25 for PPC900
New MTCX FW V01.25 for PPC900 with following changes:
- Support for B&R Hypervisor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(125)

Version 1.1.8.0:

ID: 552050
Bugfix for VC4 internal datapoints
The internal data points of VC4 and illuminated ring keys are working againfrom Automation Runtime embedded A4.33 on.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57226_0.fw(124)

Version 1.1.7.0:

ID: 507825
Serial number for 5PPC2100 and 5PC901 read incorrectly by function block and SDM
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 533575
New MTCX FW V01.24 for PPC900
New MTCX FW V01.24 for PPC900 with following changes:
- Support for IF option 5AC901.ICAN-01.
- Support syncronization byte for BRADI interface over several OS systems.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(124)

Version 1.1.6.0:

ID: 487380
New MTCX FW V01.23 for PPC900
New MTCX FW V01.23 for PPC900 with following changes:
- Bugfix: sporadical verify problems during a FW upgrade on a Automation Panel connected with SDL. The problem is actually only seen with long SDL cables starting with 20m.
- Optimization of the Suspend/Resume function for USB devices connected withSDL-Link.
- Support for AP5000 Key Extensions.
- Optimization of the maximum inrush current at minimum input voltage of thePPC900 system.
- Bugfix: "Thermal Runaway" effect of the 5AC901.BUPS-xx battery units.
- Optimized SDL equalizer settings.
- Bugfix: withoperating temperatures under 5°C, there are sporadic problems during the SDL connection establishment using the SDL cable with extender (5CASDL.0xx0-13).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(123)

Version 1.1.5.0:

ID: 438285
New MTCX FW V01.19 for PPC900
New MTCX FWV01.19 for PPC900 with following changes:
- Optimized internal memory handling for the MTCX processor.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(119)

Version 1.1.4.0:

ID: 434800
New MTCX FW V01.18 for PPC900
New MTCX FW V01.18 for PPC900 with following changes:
- Support for Panels with external backlight LED driver (e.g.: AP1000).
- Bugfix: if a 5AC901.IUPS-xx (internal UPS) is used without a 5AC901.BUPS-xx (battery unit) under AR, no NMI was generated in a PowerFail case.
With normal UPS operation (with connected battery unit) this problem does not occur.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 436080
Bugfix for Modbus TCP with ARwin
From Automation Studio version 4.1 and ARwin version G4.10 on the PPC900 can be used as Modbus TCP slave.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57226_0.fw(118)

Version 1.1.2.0:

ID: 415650
MTCX Upgrade to version V01.17
New MTCX FW V01.17 with following changes:
- Bugfix: sporadic problem with jumping cursor on Intelli touchscreens (customized systems).
- Support: FW upgrade for the external SDL3 converter box (5COSD3.1000-00).
- Optimized measurement interval for the internal temperature sensors.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(117)

Version 1.1.1.0:

ID: 397025
MTCX Upgrade to version V01.15
MTCX V01.14 to V01.15
- Support for IF option 5AC901.ISIO-00.
- Bugfix: negative CPU temperature.
MTCX V01.13 to V01.14
- Support forbus unit 5AC902.BX02-02.
- Optimization PS in standby mode.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(115)

Version 1.1.0.1:

ID: 375195
AS4.x: Ethernet I/O Mapping added

New MTCX version V1.13
AS4.x: When Modbus is activated, the corresponding data points are available in Automation Studio.
MTCX:
-Power supply change because of Clampdiods.
-Power supply change for Ready Relay Module (5V, 3V3 OFF in standby).
-Improved error handling when display addressing.
-Workaraund for batteries, which become too hot.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\57226_0.fw(113)

Version 1.1.0.0:

ID: 373165
Support for 5PC901.TS77-00
The CPU board for Panel PC 900 is supported with Automation Studio V4.0.17.x.
In addition, the minimum version H4.06 or F4.08 of Automation Runtime must beused.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\57226_0.fw(109)